Getting Started

This section outlines one of the simpler methods of getting familiar with your BASIS and the QSControl.net software. The goal of this 
procedure is to get your computer and the BASIS connected and communicating and the QSControl.net software installed and running. 
After the software is installed and running, refer to the software’s Help file for all software related operation/issues. Note! The default 
password for the BASIS is “qsc” (no quotes, lower case).

1-

 Turn off the computer and unplug the power cord from the BASIS 922uz.

2-

 Connect a CAT-5 crossover cable from the computer’s network interface card (NIC) to the BASIS QSControl jack (example 1, page 6).

3-

 Reconnect the power cord to the BASIS 922uz (turn it on). Using the BASIS LCD display and controls, navigate the menu to the IP 

Address and make a note of it. In steps 12 and on, you will need to change the IP address of the BASIS or your PC. 

4-

 Turn on the PC and start Windows. You must have Administrator rights and be signed on as Administrator in order to install the 

QSControl.net program. Ensure you are signed on to the computer as the Administrator.

5-

 Place the QSControl.net CD-ROM in your CD-ROM drive. The install wizard should start. If not, you can also select 

Start, 

then 

Run

 

and browse for the file named 

setup.exe

 from the CD.

6-

 The installer queries the computer for available drive space and other information. If required MDAC library (Microsoft) files are not 

already on the computer, the library files are installed. You must accept the Microsoft software agreement in order to install the MDAC 
library. It may be necessary to reboot the computer after library installation.

7-

 At the prompt for “Client/Server” selection, keep both Client and Server selected. This will be appropriate for general use.

8- 

When prompted “Select Installation Folder”, specify the installation directory or accept the default location. 

9-

 You will be prompted to select an installation accessible by everyone (non-secure) or an installation accessible only to you (secure). 

Select the appropriate Everyone or Just Me box and continue. Installation proceeds.

10-

 Reboot only if your computer prompts you to do so.

11-

 Select 

Network Connections

 in the control panel. Select 

Properties

. Right-click 

Local Area Connection

, and view its proper-

ties. Highlight the 

Internet Protocol (TCP/IP)

 tab and view its properties. You will see an entry field for the IP address. Decide 

whether you want to change the IP address of your computer to be similar that of to the BASIS (easiest if you have many BASIS units) 
or if you want to change the IP address of your BASIS to be similar to that of the computer. This is a network management decision.

12- 

Change the IP address of the BASIS (or computer) to be compatible with that of the computer (or BASIS). Typically, this is done by 

making the IP address of one of the devices 1 digit different in the last octet (group of digits in IP address). If changing the computer’s 
settings, write down the current values, in case you want to revert later.

13-

 The subnet mask address should be exactly the same for both the computer and the BASIS. The Gateway address should not be 

altered as it is not used.

14-

 After you are satisfied with all your settings, close all open windows and start the QSControl.net program. Select 

Start

All Pro-

grams

QSControl.net

Venue Manager.

15-

 The login screen should open. The default password is “qsc” (lower case, no quotation marks). Select “Log on to Local Computer” 

and click OK.

16-

The QSControl.net Venue Manager window will open. A Startup Tips screen will be visible the first time Venue Manager is 

launched. Optionally, the Startup Tips screen may be disabled by un-checking the box in it’s lower left corner. It is

 highly recom-

mended

 the user become familiar with each of the tips listed on this screen. After reviewing the tip(s), close the Startup Tips screen.

Содержание BASIS 922uz

Страница 1: ...TD 000197 00 rev A TD 000197 00 BASIS 922uz 8x8 CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual...

Страница 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Страница 3: ...e BASIS 922uz also offers a front panel inter face for accessing a few critical functions A single QSControl net server computer can support several clients running QSC s latest Venue Manager software...

Страница 4: ...an be easily updated over the network In the future QSC will be adding new capabilities to both BASIS and QSControl net Our latest code releases and access to up to date information on BASIS and QSCon...

Страница 5: ...ing to the proper rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background...

Страница 6: ...loyments QSControl net is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl...

Страница 7: ...would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is just like making RS 232 connections exc...

Страница 8: ...riate destination anywhere on the network Though the example shows only two BASIS 922uz units as many devices may be connected as there are available switch ports All BASIS units will be able to commu...

Страница 9: ...ol net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for BASIS 922uz control and monitoring including the system controller and a...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...or out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack M...

Страница 12: ...ws 95 98 and ME platforms are not supported Note If system is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Pa...

Страница 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 922uz to sy...

Страница 14: ...cau tion when connecting equipment particulary unbalanced equip ment Omni In The six Omni In connectors are two pin terminal block connectors They accept contact closure TTL logic signals 0 5 VDC con...

Страница 15: ...ing This can be four 2 channel amplifiers or one 8 chan nel amplifier or other suitable combinations To connect the cable orient the connector properly then push into the receptacle until it is firmly...

Страница 16: ...tches on either side provide data access and editing capability The push button switches on either side of the display are used to navigate through the menus The rotary select accept knob is active fo...

Страница 17: ...creen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow characters indicate right side button context If additional menus are available the arr...

Страница 18: ...ecify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Sele...

Страница 19: ...applied to the BASIS 19 Click on the sign of the BASIS 922uz in the inventory root then the sign of the Flashed Configs Click on the config with the loudspeaker icon A view of applicable device tabs...

Страница 20: ...lu tion off of the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs...

Страница 21: ...unicate with the BASIS 922uz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Страница 22: ...d click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lett...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the BASIS 922uz you want to communicate with in the text box and cli...

Страница 24: ...ts 8 Connector Type 4 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock Lengths 1 2 3 4 5 6 10 and 20 ft custom lengths available...

Страница 25: ...ts 6 discrete inputs for TTL logic voltage control or passive resistive Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pino...

Страница 26: ...26 Dimensions...

Страница 27: ......

Страница 28: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Отзывы: