QSC BASIS 922uz Скачать руководство пользователя страница 15

15

Monitor Chain connection. 
See explanation, at left.

In

Out

Monitor Chain

The 

MONITOR CHAIN

 connector is a 5-pin terminal block connector. Input and output con-

nections are balanced. The center pin is the shield connection for 

both

 the input and output 

of the monitor chain. Connection is shown at right. The left-most + and - terminals are for 
monitor chain input signals, while the right-most terminals are for monitor chain output sig-
nals. When powered down, a relay connects the input to the output, thus bypassing the 
BASIS 922uz in the monitor chain. 

RS-232

The RS-232 is an optional utility serial port for accessing advanced features. Connect to an 
available COM port on your PC and communicate using a terminal control program such as 
Windows Hyperterminal.

Use a normal serial data cable with a DB-9 male plug to connect to the BASIS 922uz. To con-
nect the cable, orient the connector properly, then push into the receptacle until it is firmly 
seated; tighten the retaining screws “finger tight”. Communications should be 9600 baud, 
no parity, 8 data bits, 1 stop bit, and flow control Xon/Xoff.

Ports

PORT A

 through 

PORT D

 are QSC DataPorts. When using the BASIS 922uz with QSC 

DataPort-equipped amplifiers or QSC DSP products (DSP-3, DSP-4) connect to the BASIS 
922uz using QSC DataPort cables. The 922uz supports up to eight channels of DataPort 
audio and amplifier status monitoring. This can be four 2-channel amplifiers or one 8-chan-
nel amplifier or other suitable combinations.

To connect the cable, orient the connector properly, then push into the receptacle until it is 
firmly seated; tighten the retaining screws “finger tight”.

LED Indicators

When the BASIS 922uz is plugged into a properly functioning AC outlet, it will power up and 
briefly display a welcome screen on the LCD display.

POWER Indicator- 

This blue indicator illuminates when the BASIS 922uz is plugged into a 

properly functioning AC source. There is no power switch on the BASIS 922uz. This helps to 
prevent accidental system shutdowns.

DIAGNOSTIC Indicator- 

This red diagnostic LED reports several possible operational con-

ditions. During boot-up, it is used to continually blink a “dot-dash” pattern if the power-on 
memory self-test fails. During normal operation, if any non-recoverable system fault occurs, 
the diagnostic indicator will remain on, requiring a power restart. If this condition persists, 
contact QSC’s Technical Services for assistance.

The diagnostic LED is also used to indicate an update is in progress during a remote firm-
ware update cycle. First, the LED will blink slowly, indicating the memory erase cycle, then it 
will blink rapidly, indicating the memory write cycle. 

NOTE! During a firmware update, it 

is critical the unit remain powered on for the entire process in order to complete 
successfully.

The diagnostic LED may also be controlled by using the QSControl.net software. This fea-
ture is particularly helpful for identifying a particular unit.

(continued, next page)

Содержание BASIS 922uz

Страница 1: ...TD 000197 00 rev A TD 000197 00 BASIS 922uz 8x8 CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual...

Страница 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Страница 3: ...e BASIS 922uz also offers a front panel inter face for accessing a few critical functions A single QSControl net server computer can support several clients running QSC s latest Venue Manager software...

Страница 4: ...an be easily updated over the network In the future QSC will be adding new capabilities to both BASIS and QSControl net Our latest code releases and access to up to date information on BASIS and QSCon...

Страница 5: ...ing to the proper rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background...

Страница 6: ...loyments QSControl net is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl...

Страница 7: ...would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is just like making RS 232 connections exc...

Страница 8: ...riate destination anywhere on the network Though the example shows only two BASIS 922uz units as many devices may be connected as there are available switch ports All BASIS units will be able to commu...

Страница 9: ...ol net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for BASIS 922uz control and monitoring including the system controller and a...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...or out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack M...

Страница 12: ...ws 95 98 and ME platforms are not supported Note If system is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Pa...

Страница 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 922uz to sy...

Страница 14: ...cau tion when connecting equipment particulary unbalanced equip ment Omni In The six Omni In connectors are two pin terminal block connectors They accept contact closure TTL logic signals 0 5 VDC con...

Страница 15: ...ing This can be four 2 channel amplifiers or one 8 chan nel amplifier or other suitable combinations To connect the cable orient the connector properly then push into the receptacle until it is firmly...

Страница 16: ...tches on either side provide data access and editing capability The push button switches on either side of the display are used to navigate through the menus The rotary select accept knob is active fo...

Страница 17: ...creen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow characters indicate right side button context If additional menus are available the arr...

Страница 18: ...ecify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Sele...

Страница 19: ...applied to the BASIS 19 Click on the sign of the BASIS 922uz in the inventory root then the sign of the Flashed Configs Click on the config with the loudspeaker icon A view of applicable device tabs...

Страница 20: ...lu tion off of the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs...

Страница 21: ...unicate with the BASIS 922uz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Страница 22: ...d click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lett...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the BASIS 922uz you want to communicate with in the text box and cli...

Страница 24: ...ts 8 Connector Type 4 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock Lengths 1 2 3 4 5 6 10 and 20 ft custom lengths available...

Страница 25: ...ts 6 discrete inputs for TTL logic voltage control or passive resistive Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pino...

Страница 26: ...26 Dimensions...

Страница 27: ......

Страница 28: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Отзывы: