Preliminary Specification

Control Room Foldback Monitoring

Connector Type

5-pin "Phoenix Style" (a.k.a. "Euro Style") detachable terminal blocks

Pinout

1:+(input)  2:-(input)  3:CHASSIS GND  4:-(output) 5:+(output)

Tap points

8 internal input, 8 internal output, 8 amplifier (pre-, post-, amplifier) software-selectable

Monitor Input

Monitor Signal (unit off)

Unity gain connection, relay bypass

Maximum level

+21 dBu

Impedance (nominal)

10K ohms

CMRR, 20Hz-20KHz

>54 dB

Monitor Output

Monitor

Sum of Monitor Input and signal from internal monitor tap point(s)

Freq. Resp. 20Hz-20KHz

+/- 0.5dB

Distortion (20Hz-20KHz)

<0.05% @ +4dBu

Noise Floor

>90dB

Output Impedance (nom)

100 Ohms

Output Load (min)

600 Ohms

Monitor Level

Control Range (nom)

0dB to -95.5dB in 0.5dB steps

Relay Outputs

2 discrete floating relay switch outputs

Connector Type

3-pin "Phoenix Style" (a.k.a. "Euro Style") detachable terminal blocks

Configuration

Electromechanical Relay

Pinout

1:NC  2:NO  3: COM

Switching Capacity (nom)

1A 30VDC 

Logic Outputs

4 discrete outputs

Connector Type

2-pin "Phoenix Style" (a.k.a. "Euro Style") detachable terminal blocks

Configuration

Single-ended, TTL compatible

Pinout

1:+(Signal)  2:-(CHASSIS GND)

Omni Inputs

6 discrete inputs for TTL logic, voltage control or passive resistive

Connector Type

2-pin "Phoenix Style" (a.k.a. "Euro Style") detachable terminal blocks

Configuration

Single-ended, ground referenced

Pinout

1:+(Signal)  2:-(CHASSIS GND)

Normal Operating Range

Reads signals between 0-5V nominally

Potentiometer Operation

Use 10K for full range

Voltage Tolerance

+/- 48V

Current Output

0.5mA with 10K pot (for passive resistive controls)

RS-232 Port

Female DB9 Connector

QSControl.net

Neutrik Ethercon RJ45 Ruggedized Data Connector

CobraNet

Neutrik Ethercon RJ45 Ruggedized Data Connector

Indicators

QSControl Status

Yellow Link, Tx, Rx, front panel / Green Link, Tx, Rx, rear panel

CobraNet Status

Yellow Link, TX, RX, front and rear panel

Power

Blue, front panel

Diagnostic

Red, front panel

DataPort Status (Port)

Tri-state (red, green, yellow), front panel

LCD Data Display

2 line x 16 character, backlit, front panel

Dimensions

18.89” (479.8mm) W x 1.73” (43.9mm) H x 15.00” (381.1mm) D

Weight

10.10 lb. (4.58 kg)

Specifications are subject to change without notice.

Содержание BASIS 922dz

Страница 1: ...TD 000202 00 rev B TD 000202 00 BASIS 922dz 8x8 CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual...

Страница 2: ...d 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE STA...

Страница 3: ...22dz also offers a front panel interface for accessing a few critical functions A single QSControl net server computer can support several clients running QSC s latest Venue Manager software Thus the...

Страница 4: ...asily updated over the network In the future QSC will be adding new capabilities to both BASIS and QSControl net Our latest code releases and access to up to date information on BASIS and QSCon trol n...

Страница 5: ...ing to the proper rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background...

Страница 6: ...loyments QSControl net is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl...

Страница 7: ...would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is just like making RS 232 connections exc...

Страница 8: ...riate destination anywhere on the network Though the example shows only two BASIS 922dz units as many devices may be connected as there are available switch ports All BASIS units will be able to commu...

Страница 9: ...ol net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for BASIS 922dz control and monitoring including the system controller and a...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...r out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mo...

Страница 12: ...ws 95 98 and ME platforms are not supported Note If system is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Pa...

Страница 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 922dz to sy...

Страница 14: ...ccept contact closure TTL logic signals 0 5 VDC control voltages or 10k ohm variable resistors The contact closure and logic devices accommodate on off or state change events the variable resistor inp...

Страница 15: ...table combinations If connecting a multi DataPort amplifier be sure to connect all the DataPorts to the same BASIS This practice assures proper amplifier reporting in QSControl net To connect the cabl...

Страница 16: ...of the display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting cho...

Страница 17: ...irst setting up a network system Once user moves to a different screen the last screen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow charac...

Страница 18: ...ecify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Sele...

Страница 19: ...applied to the BASIS 19 Click on the sign of the BASIS 922dz in the inventory root then the sign of the Flashed Configs Click on the config with the loudspeaker icon A view of applicable device tabs w...

Страница 20: ...lu tion off of the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs...

Страница 21: ...unicate with the BASIS 922dz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Страница 22: ...d click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lett...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the BASIS 922dz you want to communicate with in the text box and cli...

Страница 24: ...ES EBU sample rate must be 48KHz and is internally synchronized Program Outputs 8 Connector Type 4 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in f...

Страница 25: ...onnector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended TTL compatible Pinout 1 Signal 2 CHASSIS GND Omni Inputs 6 discrete inputs for TTL logic voltag...

Страница 26: ...26 Dimensions...

Страница 27: ......

Страница 28: ...ts suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products wi...

Отзывы: