Introduction - Networking the BASIS 922dz

The BASIS 922dz has two RJ-45 network connection ports on the rear panel. One port is labeled "QSControl" and supports standard 
10BASE-T Ethernet.  The other port is labeled "CobraNet" and supports 100BASE-TX, also known as "Fast Ethernet". In the following 
sections we describe the use of these ports and show example network connection schemes.

The BASIS 922dz supports two distinct kinds of network activity; the first is audio transport via CobraNet, and the second is control and 
monitoring via QSControl.net. The user can choose to install one network for CobraNet traffic and a second separate network for 
QSControl.net traffic. We call this the "Two Wire Interface". Alternately, it is possible to run both control and audio traffic over Cobra-
Net via the CobraNet port. In this case the QSControl port is unused. We call this the "Single Wire Interface".

Under the most demanding real-time control conditions and when using the lowest latency CobraNet settings, users may experience 
better QSControl.net performance using separate networks, especially when displaying a great many real-time meters. For most appli-
cations, separate networks won't provide any discernible benefits and will cost more. We therefore recommend using the Single Wire 
Interface when running CobraNet. 

If your application uses only analog I/O without CobraNet, then you should use the QSControl port for QSControl.net traffic and ignore 
the CobraNet port.

Why CobraNet Needs Special Treatment:

Ordinary Ethernet traffic has no guaranteed time of delivery. Packets of information may arrive at their destination out of order and 
some may be delayed more than others. This is fine for E-mail and even for downloading MP3 files over the Internet. Everything ends up 
properly reassembled at the destination, but how long this takes will vary according to network loading, span, etc. In contrast, Cobra-
Net is "real time" - it delivers audio with a minimal, consistent transmission delay. CobraNet is designed to use as much of conventional 
networking technology as possible while providing both guaranteed time of delivery and isochronicity - maintaining a phase-locked 
sample-accurate clock across the entire network. These requirements mean that ordinary unregulated Ethernet data cannot be freely 
mixed with CobraNet information. The two can coexist on the same wire, but only by adhering to the proper rules.

To learn more about CobraNet and appropriate network topologies, please visit http://www.qscaudio.com/products/network/
resources.htm and http://www.peakaudio.com/CobraNet/background.html.

Notes on Network Systems Design:

As with any communications system, the reliability and performance of a local area network is intimately related to the designer's skill 
and knowledge in implementing a topology that is robust, efficient and standards-compliant. Proper network design is even more criti-
cal in distributed multimedia systems. Therefore, it is important for the system designer to realize that some conventional network 
practices must be avoided. Although each network design is unique and may carry its own performance requirements, compliance to 
the following three points will assist in building an audio network that is trouble free and efficient. 

First, audio and conventional data communications deliveries should not exist on the same LAN or VLAN. The exception to this is the 
BASIS 922dz Single Wire Interface, which offers a solution for converging audio and QSControl.net onto the same LAN or VLAN. How-
ever, conventional communications, such as corporate networks, print services, e-mail and Internet access, should not exist alongside 
CobraNet audio and QSControl.net on the same LAN or VLAN. Further, CobraNet audio and QSControl.net data should not exist 
together on the same LAN or VLAN when implementing the Two Wire Interface. This is not to say that conventional communications 
cannot share the same network hardware with a BASIS 922dz. In fact, common network hardware, such as managed Ethernet switches 
and media converters, can service both BASIS 922dz products and conventional data communications equipment so long as the man-
aged switch or media converter are partitioned into separate network domains. This is normally done by configuring a separate VLAN 
for each data type. (Some switches may allow individual port assignments or support partitions through DIP switch selection.)

Second, CobraNet audio must traverse either a repeater domain or a network switch domain. The point here is that the CobraNet port 
on a BASIS 922dz must connect directly to, and only to, either a repeater LAN or a switched Ethernet LAN. Hybrid networks containing 
both repeaters and switches are not permitted on the audio segment. Connecting the CobraNet port to a repeater that is in turn con-
nected to a network switch poses an illegal and non-compliant condition. We recommend always connecting the QSControl and/or 
CobraNet port(s) directly to network switch ports. 

Содержание BASIS 922dz

Страница 1: ...TD 000202 00 rev B TD 000202 00 BASIS 922dz 8x8 CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual...

Страница 2: ...d 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE STA...

Страница 3: ...22dz also offers a front panel interface for accessing a few critical functions A single QSControl net server computer can support several clients running QSC s latest Venue Manager software Thus the...

Страница 4: ...asily updated over the network In the future QSC will be adding new capabilities to both BASIS and QSControl net Our latest code releases and access to up to date information on BASIS and QSCon trol n...

Страница 5: ...ing to the proper rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background...

Страница 6: ...loyments QSControl net is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl...

Страница 7: ...would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is just like making RS 232 connections exc...

Страница 8: ...riate destination anywhere on the network Though the example shows only two BASIS 922dz units as many devices may be connected as there are available switch ports All BASIS units will be able to commu...

Страница 9: ...ol net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for BASIS 922dz control and monitoring including the system controller and a...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...r out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mo...

Страница 12: ...ws 95 98 and ME platforms are not supported Note If system is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Pa...

Страница 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 922dz to sy...

Страница 14: ...ccept contact closure TTL logic signals 0 5 VDC control voltages or 10k ohm variable resistors The contact closure and logic devices accommodate on off or state change events the variable resistor inp...

Страница 15: ...table combinations If connecting a multi DataPort amplifier be sure to connect all the DataPorts to the same BASIS This practice assures proper amplifier reporting in QSControl net To connect the cabl...

Страница 16: ...of the display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting cho...

Страница 17: ...irst setting up a network system Once user moves to a different screen the last screen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow charac...

Страница 18: ...ecify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Sele...

Страница 19: ...applied to the BASIS 19 Click on the sign of the BASIS 922dz in the inventory root then the sign of the Flashed Configs Click on the config with the loudspeaker icon A view of applicable device tabs w...

Страница 20: ...lu tion off of the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs...

Страница 21: ...unicate with the BASIS 922dz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Страница 22: ...d click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lett...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the BASIS 922dz you want to communicate with in the text box and cli...

Страница 24: ...ES EBU sample rate must be 48KHz and is internally synchronized Program Outputs 8 Connector Type 4 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in f...

Страница 25: ...onnector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended TTL compatible Pinout 1 Signal 2 CHASSIS GND Omni Inputs 6 discrete inputs for TTL logic voltag...

Страница 26: ...26 Dimensions...

Страница 27: ......

Страница 28: ...ts suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products wi...

Отзывы: