QOLSYS ADC-IS-300-LP Скачать руководство пользователя страница 7

INSTALLATION: PREPARING PANEL FOR ENROLLMENT

1.

Create Alarm.com Customer Account

- Select service plan (see Service Plan Requirements) and register the

Alarm.com module serial number on the Alarm.com Dealer Website.

2.

Install Image Sensor Daughterboard if necessary

. – First check Hardware Compatibility to verify if module

needs a daughterboard. If it does, see Daughterboard Install Guide for daughterboard installation instructions.

3.

Install Alarm.com Module inside Control Panel

4.

Register Module and Test

- Power up the panel and initiate a comm-test to ensure the Alarm.com module is

properly installed and communicating with the Alarm.com NOC.

5.

Enroll Sensor in Panel

– Instructions specific by panel

INSTALLATION: ENROLLING IMAGE SENSOR TO PANEL

Qolsys IQ Panel / DSCTouch

Install Process:

Enroll Sensor in Panel - To enroll the sensor on an IQ Panel, follow these steps at the control panel:

1. Put the panel into add mode. On the panel, select the “Settings” icon at the bottom left hand corner of the

homepage > Enter the installer code (1-1-1-1 by default) > Select the “Installation” > Select the “Security Sensors”
> Select the “Auto Learn Sensor”.

2. Once on the Auto Learn page, insert the batteries into the Image Sensor. The Image Sensor will progress from

blinking red to solid red to blinking yellow. This indicates that the Image Sensor is in learn mode.

3. Wait approximately 20 seconds for the Image Sensor to enroll to the panel. The screen on the control panel will

display the following: “Image Sensor [X] is requesting to be added in your list. Do you want to continue? ” > Click
OK. The LED on the Image Sensor will turn solid yellow indicating that it has successfully found the panel.

4. On the panel screen, select the sensor type, sensor name, chime type, sensor group and voice prompt settings.

Make sure the Image Sensor name is unique to that Image Sensor. The Image Sensor will NOT enroll successfully
if the new Image Sensor has the same name as an Image Sensor that is already enrolled on the panel. Select
“Add New”.

5. Exit “Auto-Learn” mode on the panel. The Image Sensor LED will alternate between green and yellow while the

customer’s device list is updated with Alarm.com. The LED will turn solid green when the Image Sensor has been
successfully added to the customer’s account. Note: If you move (tamper) the Image Sensor after the LED has
turned solid green, the Image Sensor will enter test mode for 3 minutes indicated by red LED when motion is
detected. You may continue with the mounting portion of the installation when in test mode. See the Image Sensor
LED Reference Chart for more details.

The sensor is now learned into the panel. Sensors are enrolled in group 17 by default. To change the sensor group after
the sensor is enrolled, use the Edit Sensor icon under Settings > Installation > Security Sensors. Image Sensors may be
enrolled in groups 15, 17, 20, 25 or 35. After enrollment, be sure to keep the sensor and panel powered so the sensor
can complete an initialization process with the Alarm.com Network Operations Center. This process will take several
minutes. Images cannot be captured until initialization is complete.

Qolsys IQ Panel 2

Install process:

https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor_Installation_Guide_-_ADC-IS-300-LP

Updated: Tue, 17 Apr 2018 13:46:50 GMT

7

Содержание ADC-IS-300-LP

Страница 1: ...ity and pet immunity settings Image VGA 640x480 pixels Color Images except in night vision Night vision image capture with infrared flash black white Tamper detection walk test mode supervision All sy...

Страница 2: ...sor and Z Wave devices No additional hardware is needed PET IMMUNITY SETTINGS Two parts to making the Image Sensor pet immune 1 Set PIR sensitivity settings to low 2 Mount set at a height of 6 ft and...

Страница 3: ...a LED Chart Refer to this chart to understand the camera LED patterns https answers alarm com Installation_and_Troubleshooting Image_Sensor Qolsys_IQ_Panel_2_Image_Sensor Qolsys_IQ_Panel_2_Ima Updated...

Страница 4: ...https answers alarm com Installation_and_Troubleshooting Image_Sensor Qolsys_IQ_Panel_2_Image_Sensor Qolsys_IQ_Panel_2_Ima Updated Tue 17 Apr 2018 13 46 50 GMT 4...

Страница 5: ...et An Image Sensor must be network reset when it has been previously enrolled on a different panel The Image Sensor will indicate that it is enrolled on a panel by blinking green after the memory chec...

Страница 6: ...s Select the View button for the sensor to configure Select Sensor Tests and then press Start PIR Test The screen will display The PIR test is now in progress Note It may take up to 30 seconds for tes...

Страница 7: ...lick OK The LED on the Image Sensor will turn solid yellow indicating that it has successfully found the panel 4 On the panel screen select the sensor type sensor name chime type sensor group and voic...

Страница 8: ...ype sensor group and voice prompt settings Make sure the Image Sensor name is unique to that Image Sensor CHJ1 CHJ2 The Image Sensor will NOT enroll successfully if the new Image Sensor has the same n...

Страница 9: ...etermine the desired mounting angle 3 options 2 Screw bracket to back plate https answers alarm com Installation_and_Troubleshooting Image_Sensor Qolsys_IQ_Panel_2_Image_Sensor Qolsys_IQ_Panel_2_Ima U...

Страница 10: ...os Use the provided large screws and anchors to attach the bracket to the wall Leave at least 3 inches of clearance above the sensor to allow for battery replacement without uninstalling the mounting...

Страница 11: ...her and remaining small screw to secure the lock pin by screwing upwards through the bottom of the hole in the mounting bracket 7 Set PIR Sensitivity Settings 3 options that can be set through the pan...

Страница 12: ...nsite to test by running a comm test at the panel 4 Test night captures DELETING IMAGE SENSOR FROM PANEL Instructions on how to properly delete and Image Sensor from a system It is important to do the...

Страница 13: ...onds Verify Sensor is Not Communicating with Another Network If the sensor has been previously enrolled in a different system or daughterboard delete the sensor from the system and hold the sensor res...

Страница 14: ...y be uploaded to Alarm com Automatic uploads are automatically enabled after four hours Enable uploads sooner from the Dealer Website False Motion Activations Check Environmental Elements Heating or c...

Отзывы: