QOLSYS ADC-IS-300-LP Скачать руководство пользователя страница 2

• Operating Temperature Range: 60° to 80°F

• Weight: 3.1 oz. (with batteries and without mounting accessories)

• Dimensions: 3.1’’ h x 1.8’’ w x 2.3’’ d

• Supervisory Interval: 100 minutes (sensor), 3 hours (alarm hardwire)

• Wireless Signal Range: Greater than 400 ft open air

• Color: White

• Recommended Mounting Height and Angle: Refer to the Recommended Install Height and Angle Table

• Motion Profiles & Sensor Range: Refer to the PIR Sensitivity Settings Table

HARDWARE COMPATIBILITY REQUIREMENTS – By Panel

Compatibility - All Versions

OTHER FEATURE COMPATIBILITY

Two-Way Voice Compatibility -

Images cannot be transmitted while a Two-Way Voice call is in session. When the

Image Sensor is installed on a system with Two-Way Voice over the cellular network, image transmission during an
alarm may be interrupted by the two-way session. The image transmission resumes once the call has terminated.

Z-Wave Compatibility

- All IQ Panels are compatible with both the Image Sensor and Z-Wave devices. No additional

hardware is needed.

PET IMMUNITY SETTINGS

Two parts to making the Image Sensor pet immune:

1. Set PIR sensitivity settings to “low”,

2. Mount set at a height of 6 ft, and install the sensor with the 6 degree mounting angle.

BATTERIES

Battery type

: The Image Sensor uses 2 AA 1.5v Energizer Ultimate Lithium batteries (UL compliant).

Expected Battery Life

: Approximately 4 years with lithium batteries.

Voltage Thresholds

: With lithium batteries, low battery alerts are issued at 3.05V. The sensor cannot operate when the

voltage reads below 2.30V.

Low Battery Notification

: Panel will display a low battery alert for the sensor and/or notifications are issued via the

Alarm.com platform if the customer has subscribed to this notification type.

Replacing batteries

: To replace the sensor batteries, slide the front of the sensor up off the sensor-back. Dispose of

used batteries per the battery manufacturer instructions and following local regulations.

https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor/Qolsys_IQ_Panel_2_Image_Sensor_Installation_Guide_-_ADC-IS-300-LP

Updated: Tue, 17 Apr 2018 13:46:50 GMT

2

Содержание ADC-IS-300-LP

Страница 1: ...ity and pet immunity settings Image VGA 640x480 pixels Color Images except in night vision Night vision image capture with infrared flash black white Tamper detection walk test mode supervision All sy...

Страница 2: ...sor and Z Wave devices No additional hardware is needed PET IMMUNITY SETTINGS Two parts to making the Image Sensor pet immune 1 Set PIR sensitivity settings to low 2 Mount set at a height of 6 ft and...

Страница 3: ...a LED Chart Refer to this chart to understand the camera LED patterns https answers alarm com Installation_and_Troubleshooting Image_Sensor Qolsys_IQ_Panel_2_Image_Sensor Qolsys_IQ_Panel_2_Ima Updated...

Страница 4: ...https answers alarm com Installation_and_Troubleshooting Image_Sensor Qolsys_IQ_Panel_2_Image_Sensor Qolsys_IQ_Panel_2_Ima Updated Tue 17 Apr 2018 13 46 50 GMT 4...

Страница 5: ...et An Image Sensor must be network reset when it has been previously enrolled on a different panel The Image Sensor will indicate that it is enrolled on a panel by blinking green after the memory chec...

Страница 6: ...s Select the View button for the sensor to configure Select Sensor Tests and then press Start PIR Test The screen will display The PIR test is now in progress Note It may take up to 30 seconds for tes...

Страница 7: ...lick OK The LED on the Image Sensor will turn solid yellow indicating that it has successfully found the panel 4 On the panel screen select the sensor type sensor name chime type sensor group and voic...

Страница 8: ...ype sensor group and voice prompt settings Make sure the Image Sensor name is unique to that Image Sensor CHJ1 CHJ2 The Image Sensor will NOT enroll successfully if the new Image Sensor has the same n...

Страница 9: ...etermine the desired mounting angle 3 options 2 Screw bracket to back plate https answers alarm com Installation_and_Troubleshooting Image_Sensor Qolsys_IQ_Panel_2_Image_Sensor Qolsys_IQ_Panel_2_Ima U...

Страница 10: ...os Use the provided large screws and anchors to attach the bracket to the wall Leave at least 3 inches of clearance above the sensor to allow for battery replacement without uninstalling the mounting...

Страница 11: ...her and remaining small screw to secure the lock pin by screwing upwards through the bottom of the hole in the mounting bracket 7 Set PIR Sensitivity Settings 3 options that can be set through the pan...

Страница 12: ...nsite to test by running a comm test at the panel 4 Test night captures DELETING IMAGE SENSOR FROM PANEL Instructions on how to properly delete and Image Sensor from a system It is important to do the...

Страница 13: ...onds Verify Sensor is Not Communicating with Another Network If the sensor has been previously enrolled in a different system or daughterboard delete the sensor from the system and hold the sensor res...

Страница 14: ...y be uploaded to Alarm com Automatic uploads are automatically enabled after four hours Enable uploads sooner from the Dealer Website False Motion Activations Check Environmental Elements Heating or c...

Отзывы: