![QMTECH QMT 7MS028 Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/qmtech/qmt-7ms028-series/qmt-7ms028-series_operating-and-maintenance-manual_3227156008.webp)
Wiring diagram
Each pressure
transducers
and
contact gauges
is equipped with a 3 m long cable.
Pressure sensor
+
-
+
-
+
-
2
1
9-24 VDC
4-20 mA
P
I
Labeling / Manufacturing control
Each individual is marked with a data plate
containing the serial number, date and the tester's
signature. The marking can be found on the
mounting plate. See picture
to the right.
Contact gauge
1 (Brown)
4 (Black)
2 (Blue)
Connect to low alarm
Connect to common conductor
Connect to high alarm
Spare parts
QMT 78500XX
QMT 7611XXX
QMT 7200013
QMT
QMT article number
for
Reulators
Valves
Pressure gauges
Transmitter
Gas outlet
Safety relief valves
QMT 716ORGX
QMT 76SÄKXXYY
XX indicates connection diameter
XXX indicates connection diameter
X indicates gas type
XX indicates connection diameter, YY indicates
opening pressure
Address
Amerikavägen 6
393 56 KALMAR, Sweden
Phone
+46(0)480 44 02 00
Telefax
+46(0)480 44 00 10
Website/ e-post
www.qmt3.com
8