background image

3 – Virtual I/O Command Line Interface
Groups and Commands

3-30

D000025-002 Rev. A

S

Sample Output:

-> fcSrpMapConfigGet

Initiator 1, (st96) using GUID: 00066A00A0006801 SRP Ext:0000000000009601
   IOC 1 SRP Map, (p1 hitachi) is a DIRECT type. It contains 1 LUN map(s).
      All Host LUNs are passed directly to the Target (Hitachi P1 via p1)

Initiator 2, (st9602) using GUID: 00066A00A0006801 SRP Ext:0000000000009602
   IOC 1 SRP Map, (st96 hit over p2) is a DIRECT type. It contains 1 LUN map(s).
      All Host LUNs are passed directly to the Target (htachi p1 via p2)

Initiator 17, (uc blade ext1) using GUID: 0005AD000002BA4E SRP 

Ext:0000000000000001

Initiator 18, (uc blade ext2) using GUID: 0005AD000002BA4E SRP 

Ext:0000000000000002

Initiator 20, (uc blade ext4) using GUID: 0005AD000002BA4E SRP 

Ext:0000000000000004
   IOC 1 SRP Map, (maaaap) is a EXPLICIT type. It contains 3 LUN map(s).
      Host LUN 0 is mapped to Target LUN 0 on (2e7 p1)
      Host LUN 1 is mapped to Target LUN 0 on (d94 p3)
      Host LUN 2 is mapped to Target LUN 0 on (d88 p4)
   IOC 2 SRP Map, (paaaam) is a DIRECT type. It contains 1 LUN map(s).
      All Host LUNs are passed directly to the Target (b57 p4)

[Initiators 1 & 2 have one direct map. Initiators 17 & 18 have no maps. Initiator 

20 has two maps:
 explicit on IOC1 and direct on IOC2.]

Содержание SilverStorm 9000

Страница 1: ...D000025 002 Rev A SilverStorm 9000 CLI Reference Guide...

Страница 2: ...or other rights of third parties which may result from its use QLogic Corporation reserves the right to change product specifications at any time without notice Applications described in this document...

Страница 3: ...2 2 Online Help 2 4 Keyboard Shortcuts 2 4 Accessing the CLI 2 4 Groups and Commands 2 5 General 2 5 Chassis 2 28 Network 2 33 Firmware 2 39 Subnet Management 2 47 Log 2 74 Key Management 2 80 IbSwit...

Страница 4: ...Page iv D000025 002 Rev A SilverStorm 9000 CLI Reference Guide S Linecard 3 4 Firmware 3 13 Log 3 16 Capture 3 16 FibreChannel 3 19 Ethernet 3 45 Configuration 3 88...

Страница 5: ...ce and technical support Section 2 describes the 9000 switch CLI commands Section 3 describes all the Virtual I O EVIC and FVIC CLI commands Intended Audience This manual is intended to provide networ...

Страница 6: ...and software updates Availability QLogic Technical Support for products under warranty is available during local standard working hours excluding QLogic Observed Holidays Contact Information Support H...

Страница 7: ...which in many respects mirrors the functionality of the Chassis Viewer GUI The CLI is accessed via a terminal attached to the switch spine module s RS232 port s or via the OOB management port using T...

Страница 8: ...ll always have access to the switch even if Telnet and SSH are not functioning Commands and Functional Groups The list of available commands can be accessed by typing list To keep the list short the c...

Страница 9: ...nd security parameters required to access the switch from an SNMP manager Capture Providescommandsforcapturingswitch specificinformationforthepurposes of analysis and debugging To list commands within...

Страница 10: ...ard Shortcuts The CLI keeps a history of recently executed commands This history is available via the Up and Down arrow keys Users may edit the current command with the Left and Right arrow keys Tab c...

Страница 11: ...ommands Groups and Commands The following section lists all CLI functional groups along with the commands for each group Commands for all 9000 switches are listed Any commands specific to a switch es...

Страница 12: ...dings exist for the backspace and delete keys If these keys are not responding as expected use the swapBsDel command to swap the bindings Commands are grouped into subcategories To list the commands i...

Страница 13: ...only verbose Print full help for each command instead of summary list List of Valid Commands General General commands for user management and CLI configuration Deprecated These commands have been depr...

Страница 14: ...witchInfo TimeManagement Snmp Ethernet help list history reboot now m slot n s n all now Does not prompt the user before rebooting m Reboot Master local Spine 1 non disruptive slot n reset specific de...

Страница 15: ...device from telnet ssh etc you will have to reconnect after rebooting Default no arguments reboots local device disruptively after prompt See also resetCard showInventory killCliSession Terminates an...

Страница 16: ...n index logged in timestamp of when the user logged in last cmd timestamp of the users last command type method used to connect to the system ip address ip address of the user if applicable broadcast...

Страница 17: ...hout having to adjust their terminal settings Backspace and delete swapping is persistently maintained per user i e each login account can have a separate binding setTermWidth Change the terminal widt...

Страница 18: ...I prompt global for all active CLI sessions Syntax Options Sample Output NOTES This changes the prompt for all CLI sessions The prompt may not exceed 11 characters and is not saved across reboots If t...

Страница 19: ...cified option When case sensitivity is on the CLI input must match the exact character case lower and upper case as specified in the help text When case sensitivity is turned off the input may be any...

Страница 20: ...e multiple arguments they are separated by spaces rlogin Creates I O terminal to local cards Syntax Options Sample Output NOTES This command allows users to open a terminal to local I O devices within...

Страница 21: ...f rlogin See also hostShow resetCard Reboot a specific slot in the chassis Syntax Options Sample Output NOTES If you reset the switch you are connected to you will have to reconnect You can find out t...

Страница 22: ...o the operator account or to the admin account passwd Change users password s Syntax Options Sample Output NOTES Allows the modification of the user s password None logout user user user Name of user...

Страница 23: ...accounts for this device Syntax userAdd role username password role Can be either admin or operator username The name of the user to be added password Optional password If not supplied the default pas...

Страница 24: ...userListShow username role operator1 operator USERID admin Bob admin sshKey cmd u username input show Displays the SSH public keys in the users authorized_keys file add key Add key to the users author...

Страница 25: ...llowing modes should become active 0 Username and password required 1 Password is not required 2 Username password are not required 3 LDAP Authentication When usernames are disabled all users will be...

Страница 26: ...emote authentication idleTimeoutGet Retrieves the UI idle timeout value Syntax Options Sample Output NOTES Displays the system idle timeouts for the GUI and CLI interfaces If set to zero the timeout i...

Страница 27: ...OTES Disables the idle timeout for the current CLI session This value does not persist across instances of the session i e each time you log on it will default back to the system default value idleTim...

Страница 28: ...t defaults back to the system default value loginMsgGet Displays the CLI login message for this device Syntax Options Sample Output NOTES Displays the current login welcome message for the CLI This me...

Страница 29: ...ax Options Sample Output NOTE The login name is an arbitrary string displayed prior to a user attempting a login to a new CLI session This command displays the current value of this string loginNameSe...

Страница 30: ...quired on the serial console of the system serialAuthSet Enable or disable authentication on the systems serial console Syntax Options Sample Output NOTES This command is used to enable or disable use...

Страница 31: ...a single command A reboot is not required for this command Depending on the specific method it may take 5 10 seconds for the changes Notethat existing connections for example a telnet session will no...

Страница 32: ...le 9000 MPFD only Enable IpoIb feature Syntax Options Sample Output NOTES Only allowed trasition at run time is from disable to enable by default it is disabled IpoIbAddressShow 9000 MPFD only Display...

Страница 33: ...Ib IP address and associated network mask Syntax Options Sample Output exit Exit the CLI Syntax Options Sample Output IpoIbAddressShow IpoIbAddressSet h ipaddress m netMask h ipaddress the new IP addr...

Страница 34: ...turns OK or provides detailed status warning error information If an error warning is detected this command automatically provides verbose information hwMonitor Displays current port states fan speeds...

Страница 35: ...M 0m PS2 Fan Speed 5m 1 RPM 0m PS3 Fan Speed 5m 1 RPM 0m PS4 Fan Speed 9642 RPM 0m PS5 Fan Speed 9642 RPM 0m PS6 Fan Speed 9507 RPM 0m FT1 Fan Speeds 8940 RPM 0m 8820 RPM 0m FT2 Fan Speeds 9120 RPM 0m...

Страница 36: ...t is 0 the SMA node description is in a verbose format When the format is one the format is brief The brief format is more consistent with the CLI GUI Port Stat port naming fruInfo Displays the EEProm...

Страница 37: ...rdFormat 2RecLen 14 LogicalLen 020 HdrChkSum c6 ChassisGuid 00066a000300012a SlotCount 1 IB Mods in Chassis SlotNumbers 81 pairs ext0 Slt1 CmeAccess 80 bits ext0 Slt1 Cme SlotNumber 0 Record accessed...

Страница 38: ...ware within the chassis Syntax Options Sample Output chassisQuery slots 2 4 8 101 102 chassisQuery 101 showType type InfinIO9000 t3 showInventory None showInventory ___________________________________...

Страница 39: ...Subnet 0x7f000000 Metric is 0 Maximum Transfer Unit size is 32768 dp0 mgmt_eth1 is active mgmt_eth2 is disabled Flags 0x8863 UP BROADCAST MULTICAST ARP RUNNING Type ETHERNET_CSMACD Internet address 1...

Страница 40: ...the OOB LAN IP routes Syntax Options Sample Output ping Send ping packets to a specified host Syntax Options routeShow None routeShow ROUTE NET TABLE destination gateway flags Refcnt Use Interface 0 0...

Страница 41: ...Options PING 172 26 0 254 56 data bytes 64 bytes from 172 26 0 254 icmp_seq 0 time 0 ms 64 bytes from 172 26 0 254 icmp_seq 1 time 0 ms 64 bytes from 172 26 0 254 icmp_seq 2 time 0 ms 64 bytes from 17...

Страница 42: ...t gateway to route packets from the OOB mangement port to an external network setDefaultRoute Change the default gateway IP address Syntax Options Sample Output NOTES This allows the user to configure...

Страница 43: ...Syntax Options Sample Output hostShow Displays a list of remote hosts names internet address and alias es Syntax Options arpShow None arpShow LINK LEVEL ARP TABLE destination gateway flags Refcnt Use...

Страница 44: ...slot6 127 1 0 6 slot7 127 1 0 7 slot8 127 1 0 8 slot9 127 1 0 9 slot10 127 1 0 10 slot11 127 1 0 11 slot12 127 1 0 12 slot13 127 1 0 13 slot14 127 1 0 14 slot15 127 1 0 15 slot16 127 1 0 16 slot17 127...

Страница 45: ...Update 9024 Only Updates the firmware Syntax Options fwUpdate host user password dir filename host The name of the host where the firmware file resides user The FTP user name password The FTP user pas...

Страница 46: ...t3 pkg Save changes Y n Attempting to initiate firmware update Product InfinIO9000 Version 4 2 1 1 1 Compressed Image Size 4837085 bytes md5 9de07c302bb09c4335b114dc809b87ff vxWorks Image Type loadab...

Страница 47: ...The name of the host where the firmware file resides user The FTP user name password The FTP user password dir After logging in the directory to cd to filename The name of the firmware file fwUpdateS...

Страница 48: ...ach file for each line card type present The system can save the values entered as defaults for future firmware updates fwListFiles Lists the contents of the firmware directory Syntax Options Sample O...

Страница 49: ...r a specific release Syntax Options Sample Output fwSetUpdateParams c cardtype h hostname u username p password d directory f filename c cardtype Choices are manangement vfx vex ibx h hostname The hos...

Страница 50: ...push was successful or not fwVersion Displays the firmware versions for a unit Syntax Options Sample Output showLastScpRetCode slot all slot The slot number in the chassis all All slots in the chassis...

Страница 51: ...of the alternate firmware image all Displays the versions for the primary and alternate firmware images bootQuery 2 all Primary firmware version 4 2 2 0 2 Alternate firmware version 4 2 1 0 2 Active f...

Страница 52: ...age for the device A next to the image entry indicates the currently selected bootimage A indicates the currently active bootimage bootSelect 3 noprompt Currently installed firmware versions index ali...

Страница 53: ...2 47 A Subnet Management smControl Starts and stops the embedded subnet manager Syntax Options Sample Output smControl start stop restart status Start Start the SM Stop Stop the SM restart Restarts t...

Страница 54: ...configure the subnet manager Note that for runtimetype parameters the Subnet manager may need to be restarted for them to take effect smConfig startAtBoot yes no startOnSlaveCmu yes no startAtBoot Sta...

Страница 55: ...2 5 5 5 0 00000000 1 23 4 23 6 0000000000000000 4 8 8 2k 2k 4X 4X 2 5 5 5 0 00000000 1 24 4 24 7 0000000000000000 4 8 8 2k 2k 4X 4X 2 5 5 5 0 00000000 2 24 7 24 8 0000000000000000 4 8 8 2k 2k 4X 4X 2...

Страница 56: ...priority will become the master SM for the fabric smSweepRate Set display the sweep rate of the subnet manager Syntax Options Sample Output smPriority priority value priority must be between 0 and 15...

Страница 57: ...manager scans the fabric for changes and events smForceSweep Force a fabric sweep by the embedded subnet manager Syntax Options Sample Output NOTES This command has no output message To see the resul...

Страница 58: ...part of the output smShowGroups Multicast Groups join state key F Full N Non S SendOnly Member 0xff12601bffff0000 00000001ffffd5bb c001 qKey 0x00000000 pKey 0xFFFF mtu 4 rate 3 life 19 sl 0 0x00117500...

Страница 59: ...ervice Records the first slot of the empty group is displayed as empty smShowServices None smShowServices There is 1 Service Records Service ID 0x1100D03C34834444 Service GID 0xFE80000000000000 00066A...

Страница 60: ...iber Record ID 0x00000001 Subscriber Inform Info GID 0x0000000000000000 0000000000000000 Start LID 0xFFFF End LID 0x0000 Is Generic Yes Subscribe Subscribe Type All Types Trap Number 0x0040 Queue Pair...

Страница 61: ...are assigned to endports based on this value For example setting the LMC to a value of 3 will assign 2 3 or 8 LID s per endport smShowMasterLid Display the LID of the subnet manager Syntax Options Sam...

Страница 62: ...0x00066a00da000100 172 26 2 2 Spine 1 Ch Lid 0x0002 guid 0x00066a0007000170 pass 341 SilverStorm 9080 GUID 0x00066a00da000100 172 26 2 2 Leaf 4 Chi Lid 0x0003 guid 0x00066a100600013c pass 341 SilverSt...

Страница 63: ...tchLifetime Set Display the default switch lifetime in the SM Syntax Options Sample Output NOTES The switch lifetime value determines the maximum time a packet may remain in a switch calculated using...

Страница 64: ...ifetime microseconds smVLStall Set Display the VL stall value in the SM Syntax Options Sample Output NOTES Use this command to set the VL stall value for ports in the fabric This value determines the...

Страница 65: ...None smShowSMParms SM priority is set to 4 SM LMC is set to 0 SM sweep rate is set to 300 SM max retries on receive set to 3 SM max receive wait interval set to 250 millisecs switchLifetime set to 15...

Страница 66: ...ions Sample Output NOTES Use this command to set the SM key SM must be offline and key value is up to 8 byte hex smMgmtKey Set the subnet manager management key portInfo value Syntax Options Sample Ou...

Страница 67: ...s without explicit direction may cause the fabric to be inoperable smOptionConfig clear default def mcgrp create dyn plt clear Clears all set options default Enable the default set of options i e def...

Страница 68: ...MTU values are 1 256 2 512 3 1024 4 2048 and 5 4096 smDefBcGroup enable disable default pKey mtu rate sl qKey fl tc enable Enable auto creation of multicast group at SM startup disable Disable auto cr...

Страница 69: ...ETERS THAT YOUR FABRIC CANNOT SUPPORT smGidPrefix Set the Subnet Prefix default 0xfe80000000000000 Syntax Options Sample Output NOTES Use this command to set the subnet prefix of the SM The SM must be...

Страница 70: ...display the error threshold for a topology sweep Syntax Options Sample Output NOTES Sets the maximum number of errors the SM may encounter during a sweep before abandoning the sweep smTopoAbandonThres...

Страница 71: ...s Sample Output smRcvWaitTime Set display max time to wait for a reply to an SM packet in millisecs Syntax Options Sample Output smMaxRetries retries None smMaxRetries 3 Set max retries to 3 smMaxRetr...

Страница 72: ...display sweeps to wait before dropping a non responsive node Syntax Options Sample Output smNonRespDropTime seconds None smNonRespDropTime 300 Set Nonresponsive node drop time to 300 seconds smNonRes...

Страница 73: ...errors and warnings 2 for errors warnings and sweep info Values 3 4 and 5 are unused smMcLidTableCap Set display the limit of multicast LIDs available for allocation Syntax Options Sample Output NOTE...

Страница 74: ...ilures Set display number of master ping failures allowed Syntax Options Sample Output NOTES Value must be between 2 and 5 smMasterPingInterval seconds None smMasterPingInterval 4 Set master ping inte...

Страница 75: ...CHRONIZATION interval set to 900 seconds 2 SM s in fabric MASTER SM node at SilverStorm 9024 DDR GUID 0x00066a00d90003fa LID 0x0008 PortGuid 0x00066a00d90003fa Sync Capability is SUPPORTED STANDBY SM...

Страница 76: ...sec Index 7 PLT Value 18 1073741 usec Index 8 PLT Value 19 2147483 usec Index 9 PLT Value 19 2147483 usec Dynamic packet lifetime values for pathrecord queries are enabled use the smOptionConfig comma...

Страница 77: ...OTES When enabled ports generating urgent traps at a rate higher than the threshold will be disabled This value can range from 10 to 100 traps minute Set the value to 0 to disable this feature smAppea...

Страница 78: ...subsequent messages to be logged at the INFO priority smPmBmStart Set display whether the PM and BM will start with the SM Syntax Options Sample Output smAppearanceMsgThresh Message Threshold is 0 dis...

Страница 79: ...Output NOTES This displays ports that have been removed from the fabric automatically by the SM such as when a 1x link mode is set to ignore or when a port has exceeded its urgent trap threshold smSho...

Страница 80: ...pi Target Device 3 d94 p3 NPort Id 0x0106d3 Connection Restored W 2006 10 04 20 26 31 246U Thread Log 0x8fdab3b0 Log Unable to Send Trap 523 Bad 65535 W 2006 10 04 20 26 31 256U Thread CPU1 0x1 Fcpi T...

Страница 81: ...025 002 Rev A 2 75 A logClear Clears the log file Syntax Options Sample Output logConfigure Configures the log settings Syntax Options logClear noprompt noprompt delete all log messages without prompt...

Страница 82: ...vel Syslog Configure the syslog host ip address and port logConfigure Type Q or X to exit Please enter the number corresponding to what you want to configure index name description 1 Device Logging de...

Страница 83: ...in the messages Additional configuration may be necessary to fully configure the log system logResetToDefaults noprompt noprompt Restore the defaults without prompting the user logResetToDefaults Log...

Страница 84: ...s index name D F E A W P C I P N 1 2 3 4 5 1 Ram X X X X X X X X 2 BriefRam X X X X X X 3 Console X X X X X X X X X X 4 Trap X X X X X X 5 Syslog X X X X X X X Configurable presets index name state 1...

Страница 85: ...Sample Output e Send Error severity CSM test message to Syslog w Send Warning severity CSM test message to Syslog n Send Warning severity CSM test message to Syslog logSyslogTest e Currently configur...

Страница 86: ...TES License keys unlock various software features of the product addKey Add a license key Syntax Options Sample Output removeKey Remove a license key Syntax showKeys None showKeys Key number 1 Key FV7...

Страница 87: ...ommand a list of available keys will be displayed The keys are shown along with an associated number At the prompt enter the number of the key you wish to remove None removeKey Key number 1 Key XX7P91...

Страница 88: ...ayed first then cleared noprompt Does not give the user a Continue prompt for each page of display cols X Sets the number of columns to be displayed per line port X Specifies a port s to display leaf...

Страница 89: ...by one ErrRecovery The number of times the link error recovery proccess happened successfully LinkDowned The number of times the link error recovery process failed RcvErrors Number of errors received...

Страница 90: ...ause of lack of arbitration Receive Packets The number of data packets received by the port not including flow control packets Receive Words The number of data words received by the port not including...

Страница 91: ...wdb Displays the entries in the linear forwarding table LIDs and a cooresponding port are shown A packet addressed to a LID will be forwared to the cooresonding port listed in the displayed table Synt...

Страница 92: ...y be useful for diagnostics purposes specifically for bad cables This feature is only available on certain switch hardware platforms ismMultiFwdb Switch Leaf 3 Multicast Fwdb c000 12 L03P12 19 L03S1Aa...

Страница 93: ...ommand without the option enable12xBit displays the current values of the port Devices with effected ports MUST BE REBOOTED to activate changes made with ismPortSet12x ismChassisSet12x Allows the user...

Страница 94: ...able12xBit will display the current values of the port s ismChassisSetSpeed Allows the user to view and set port link speeds including external ports for the entire chassis to 2 5 SDR 5 0 DDR or AutoN...

Страница 95: ...f the port s A reboot of the chassis is required to activate changes made with this command ismPortEnable Allows the user to enable or disable a port Syntax Options Sample Output NOTE The option portN...

Страница 96: ...s ismChassisSetDdrPreemphasis Cable 1 DDR preemphasis 0x01010101 Cable 2 DDR preemphasis 0x01010101 Cable 3 DDR preemphasis 0x01010101 Cable 4 DDR preemphasis 0x01010101 Cable 5 DDR preemphasis 0x0101...

Страница 97: ...x Options Sample Output NOTE The option port is case sensitive If it contains spaces it must be bounded by quotes e g ismPortEnable Cable 1 A reboot is required to activate changes made with this comm...

Страница 98: ...it must be bounded by quotes For example ismPortSetPreemphasis Cable 1 1 Calling this function with only the option portName will display the current values A reboot is required to activate changes m...

Страница 99: ...ismIslSet12x L01S2Ba 12x mode is DISABLED L01S2Bb 12x mode is DISABLED L01S2Bc 12x mode is DISABLED L01S1Ba 12x mode is DISABLED L01S1Bb 12x mode is DISABLED L01S1Bc 12x mode is DISABLED L01S2Aa 12x...

Страница 100: ...and works only on chassis supporting DDR links This command sets inter switch link speeds to either 2 5 5 0 or AutoNegotiate External ports remain configured to SDR rate 2 5 and do not require special...

Страница 101: ...ey inbound was invalid 14 portPKeyViolOut PKey outbound was invalid 15 portRawViolIn raw inbound packet discarded 16 portRawViolOut raw outbound packet discarded 17 portLocalLinkInteg link integrity e...

Страница 102: ...Thresh Modifies the port statistic thresholds Syntax Options Sample Output NOTE The available thresholds are portXmitData portRecvData portXmitPkts portRecvPkts portSymbolErr portLinkErrRecv portLinkD...

Страница 103: ...ocalVL15Dropped portNonSMPDropped ismRemoveStateDump Removes switch ASIC state dumps files Syntax Options Sample Output ismRemoveStateDump all leaf X spine X all Removes all switch ASIC state dump fil...

Страница 104: ...put ismShowStateDump full all leaf X spine X full Shows the full contents of the switch ASIC state dump file Without this option just the header is displayed all Removes all switch ASIC state dump fil...

Страница 105: ...system time will be printed out timeZoneConf Display configure the time zone setting Syntax Options Sample Output time S ipaddr T hhmmss mmddyyyy S ipaddr Sets the NTP Server IP address T hhmmss mmddy...

Страница 106: ...be timeDSTConf 1 1 4 4 1 10 timeNtpTimeout Display or set the number of seconds to wait for a NTP response timeDSTConf sw sd sm ew ed em sw Start which valid values 1 1st 2 2nd 3 3rd 4 4th 5 5th sd S...

Страница 107: ...s or slave CMUs timeNtpRefreshTime Display or set the delay between syncing the clock via NTP Syntax Options Sample Output NOTE With no arguments this command displays the current NTP refresh time whi...

Страница 108: ...tch Command Line Interface Groups and Commands 2 102 D000025 002 Rev A S command with the new refresh time in whole seconds as the only argument The NTP refresh time is not used on linecards or slave...

Страница 109: ...ing is displayed If options are entered then the corresponding community string is changed snmpTargetAddr Displays and allows the changing of the snmpTargetAddrTable entries Syntax snmpCommunityConf r...

Страница 110: ...dotted decimal form p Port The target port to send traps and information t Timeout The time to wait for an information response r Retry count The number of re send attempts for information l Tag list...

Страница 111: ...pTargetParamsMPModel v1 params 0 rfc2573t snmpTargetParamsMPModel v2 params 1 rfc2573t snmpTargetParamsMPModel v3 params 3 rfc2573t snmpTargetParamsSecurityModel v1 params 1 rfc2573t snmpTargetParamsS...

Страница 112: ..._index value For more details on the snmpNotifyFilterTable see SNMP NOTIFICATION MIB RFC 2573 snmpNotify Displays the snmpNotifyTable entries Syntax Options snmpNotifyFilter show show Displays the con...

Страница 113: ...Tag rmon rfc1757 rfc2573n snmpNotifyTag snmp rfc1907 rfc2573n snmpNotifyTag tms tmscom rfc2573n snmpNotifyType switch 1 snmpSystem show edit n sysName l sysLocation c sysContact show show the contents...

Страница 114: ...gorithm No privacy algorithms are currently supported snmpUsrSec add show edit delete name a algo key add add an entry to the V3 user table show show entries in the V3 user table edit modify an entry...

Страница 115: ...ions NOTE This command is intended for support personnel captureFw Display firmware information for this device Syntax Options NOTE This command is intended for support personnel captureLog Display lo...

Страница 116: ...personnel captureIsm Display Infiniband switch information for this device Syntax Options NOTE This command is intended for support personnel captureChassis Display chassis information for this device...

Страница 117: ...this device Syntax Options NOTE This command is intended for support personnel captureSnmp Display SNMP information for this device Syntax Options NOTE This command is intended for support personnel...

Страница 118: ...2 Switch Command Line Interface Groups and Commands 2 112 D000025 002 Rev A S...

Страница 119: ...short the commands are grouped into functional groups which are General General administrative commands Deprecated Commands that have been deprecated The Deprecated group contains CLI commands that h...

Страница 120: ...Providescommandsforcapturingswitch specificinformationforthepurposes of analysis and debugging FibreChannel Specific to the FVIC provides commands for managing the Fibre Channel interface Ethernet Spe...

Страница 121: ...rrent command with the Left and Right arrow keys n Tab completion pressing the Tab key after typing at least one character either completes a command or lists all the available commands that begin wit...

Страница 122: ...Type list for the list of commands Groups and Commands The following section lists the CLI s functional groups along with the commands for each group For more specific information for each functional...

Страница 123: ...ard fatal error count Syntax Options cardInfo Out of Band LAN IP 172 26 2 87 Net Mask 255 255 240 0 MAC Address 00 06 6a 00 50 ba Description Empty No Value Set Alias VIO IB Node Description VIO slot...

Страница 124: ...ard uptime Syntax Options Sample Output NOTE cardInfo is a related command cardDescGet Displays linecard description Syntax Options Sample Output NOTE cardInfo is a related command cardFatalErrGet Fat...

Страница 125: ...ard description Syntax Options Sample Output NOTE cardInfo is a related command cardAliasGet Displays the linecard alias Syntax Options Sample Output NOTE cardInfo is a related command cardDescSet str...

Страница 126: ...e linecard IB node description Syntax Options Sample Output NOTE cardInfo is a related command cardIbNodeDescSet Modifies the linecard IB Node Description Syntax cardAliasSet string string Decription...

Страница 127: ...tions Sample Output NOTE cardInfo is a related command cardCardDescSet Modifies the linecard IB Node Description Syntax Options Sample Output default Default string string Description text string card...

Страница 128: ...s Sample Output NOTE cardInfo is a related command cardContactSet Modifies the linecard contact information Syntax Options Sample Output NOTE cardInfo is a related command cardNameGet Displays the lin...

Страница 129: ...difies the linecard name Syntax Options Sample Output NOTE cardInfo is a related command cardLocationGet Displays the linecard location Syntax Options Sample Output None cardNameGet Card Name FVIC 6 c...

Страница 130: ...NOTE cardInfo is a related command cardLocationSet Modifies the linecard location information Syntax Options Sample Output NOTE cardInfo is a related command cardLocationSet string string Location te...

Страница 131: ...3 13 A Firmware fwVersion Displays the firmware versions for a unit Syntax Options Sample Output fwVersion slot slot Slot number fwVersion 3 Slot 3 Information Firmware Version 4 0 0 0 32 Firmware bui...

Страница 132: ...ate firmware image all Displays the versions for the primary and alternate firmware images bootQuery SLOT NUMBER all Primary firmware version 4 0 0 0 32 Alternate firmware version 4 0 0 0 28 Active fi...

Страница 133: ...000025 002 Rev A 3 15 A Sample Output bootSelect 103 noprompt Currently installed firmware versions index alias version 1 image1 4 0 0 0 28 2 image2 4 0 0 0 32 indicates Default image will run at next...

Страница 134: ...n commands for the Log group refer to page 2 74 Capture capture Display information for this device Syntax Options NOTE This command is intended for support personnel captureFw Display firmware inform...

Страница 135: ...support personnel captureLog Display log information for this device Syntax Options NOTE This command is intended for support personnel captureMisc Display miscellaneous information for this device Sy...

Страница 136: ...an FVIC Syntax Options NOTE This command is intended for support personnel captureLinecard Displays pertinent linecard information for module Syntax Options NOTE This command is intended for support...

Страница 137: ...Ext 1 0x500066A1E0000133 0x010E00 Fabric Auto Up 4G OK Ext2 Ext 2 0x500066A2E0000133 0x000001 Private Loop 4G Up 4G OK Ext3 Ext 3 0x500066A3E0000133 0x010A00 Fabric Auto Up 4G OK Ext4 Ext 4 0x500066A...

Страница 138: ...E REBOOTED to activate changes made with fcPortSpeedSet fcPortTopologyGet port number port number Displays the current topoloogy settings for a specified port fcPortTopologyGet Admin Link Oper Port Al...

Страница 139: ...3 Fabric fcPortTopologySet 5 1 Updated the topology Note that the board needs to be rebooted in order for the change to take effect Admin Link Oper Port Alias PortWWN NPortId Topology Speed Status Spe...

Страница 140: ...b 0x500066A2DD000019 0x000000 Fabric Auto Down Not Installed 3 plc2c 0x500066A3DD000019 0x000000 Fabric Auto Down Not Installed 4 plc2d 0x500066A4DD000019 0x000000 Fabric Auto Down Not Installed 5 plc...

Страница 141: ...yntax fcDeviceDiscoveryStart None fcDeviceDiscoveryStart Fibre Channel Device Discovery cycle started fcDiscoveredDevicesGet Index Optional index of the device from the discovered device list fcDiscov...

Страница 142: ...Name 1 0x20000004CF8C02E7 0x22000004CF8C02E7 1 0x0106d1 3 Connected 2e7 p1 2 0x50060E801042B920 0x50060E801042B920 1 0x0108ef 3 Connected Hitachi P1 via p1 3 0x50060E801042B920 0x50060E801042B920 3 0...

Страница 143: ...discovery cycle for SRP Initiators Syntax Options Sample Output fcConfiguredDeviceRem 2 Removed FC Target Device 2 fcConfiguredDeviceRename Device Index Name Device Index Index number from the results...

Страница 144: ...fcSrpConfiguredInitiatorsGet Display SRP Initiators that have already been configured Syntax Options fcSrpDiscoveredInitiatorsGet None fcSrpDiscoveredInitiatorsGet Ref Initiatorport Identifier 1 0002C...

Страница 145: ...0009601 0 st96 2 00066A00A0006801 0000000000009602 1 st9602 3 00066A00A0006801 0000000000009603 0 st9603 4 00066A00A0006801 0000000000009604 0 st9604 5 00066A00A0006801 0000000000009605 0 st9605 6 000...

Страница 146: ...move a SRP Initiator from the configured list Syntax Options Sample Output fcSrpInitiatorCreate Initiator GUID SRP Extension Name Initiator GUID The InfiniBand globally unique identifier GUID of the S...

Страница 147: ...Get Retrieve SRP map configuration information Syntax Options fcSrpMapShowConnections Initiator Index Initiator Index An initiator number from the configured initiator list Executing this command with...

Страница 148: ...htachi p1 via p2 Initiator 17 uc blade ext1 using GUID 0005AD000002BA4E SRP Ext 0000000000000001 Initiator 18 uc blade ext2 using GUID 0005AD000002BA4E SRP Ext 0000000000000002 Initiator 20 uc blade...

Страница 149: ...apConfigCreate Initiator Index IOC FC Target Device Index MapType MapName Initiator Index The index number from the Configured SRP Initiators list IOC The IOC number either 1 or 2 FC Target Device Ind...

Страница 150: ...ator Index IOC Status SRP Initiator Index The index number from the Configured SRP Initiators list IOC The IOC number either 1 or 2 Status The type of SRP Map A Active or I Inactive fcSrpMapConfigStat...

Страница 151: ...Logical Unit Number TargetLUN The target Logical Unit Number fcSrpMapConfigRowAdd 18 1 14 0 0 Initiator 18 uc blade ext2 using GUID 0005AD000002BA4E SRP Ext 0000000000000002 IOC 1 SRP Map jupiter is a...

Страница 152: ...Allows the user to change the SRP map type Direct or Explicit Syntax fcSrpMapConfigRowRem 18 1 15 1 0 Initiator 18 uc blade ext2 using GUID 0005AD000002BA4E SRP Ext 0000000000000002 IOC 1 SRP Map jupi...

Страница 153: ...includes whitespace SRP Initiator Index The index number from the Configured SRP Initiators list IOC The IOC number either 1 or 2 MapType Type of SRP Map D Direct or E Explicit Host LUN Optional if no...

Страница 154: ...Port NPortId COS ConnectStatus Name Device 1 2e7 p1 NodeWWN 20000004CF8C02E7 PortWWN 22000004CF8C02E7 PortIndex 1 ConnectStatus Connected NPortId 0x0106d1 ClassOfService 3 Size in 2048 out 2048 TotalR...

Страница 155: ...itiatorStatsGet Initiator Optional Initiator Index fcSrpInitiatorStatsGet Initiator 1 st96 using GUID 00066A00A0006801 SRP Ext 0000000000009601 ActiveConnections 0 TotalRequests 0 SucceededRequests 0...

Страница 156: ...ieve the list and status of all Fibre Channle traps Syntax Options fcPortStatsGet PortNumber PortNumber The Fibre Channel port number for the device fcPortStatsGet Port Ext1 VIO 00066a00e0000133 Port...

Страница 157: ...ax Options Sample Output NOTE The Trap Index may be retrieved using fcTrapStatusGet fcTrapStatusGet Valid Traps 1 Interconnect Link Up enabled 2 Interconnect Link Down enabled 3 Target Device Link Up...

Страница 158: ...Options Sample Output NOTE The Trap Index may be retrieved using fcTrapStatusGet fcVirtPortShow Displays information about the virtual ports in the pool Syntax Options fcTrapGenerate Trap Index The in...

Страница 159: ...0E2000199 Ext 1 1 Active Test 0001 0002 0x500066A0E2200199 Unassigned Inactive WWN 0002 0003 0x500066A0E2400199 Unassigned Inactive WWN 0003 0004 0x500066A0E2600199 Unassigned Inactive WWN 0004 0005 0...

Страница 160: ...ex Name Index The index from the Virtual Port list Name The text name for the Virtual Port fcVirtPortNameSet 1 Test 0001 Index WWN Alias PhyPort Status Name 0001 0x500066A0E2000199 Unassigned Inactive...

Страница 161: ...physical port in order to be activated fcVirtPortPoolCreate Create the Virtual Port Pool from the feature key Syntax Options fcVirtPortPhyPortSet 1 2 Index VirtPort WWN PhyPort Status VirtPort Name 0...

Страница 162: ...ed to be re entered fcVirtPortPoolCreate license key Virtual Port Pool key accepted Virtual Port Pool Key license key Index VirtPort WWN PhyPort Status VirtPort Name 0001 500066A0E2000199 Unassigned I...

Страница 163: ...use while the saved MTU is the size that will be used following a reboot ethMtuSet Set the MTU size to be used after the next reboot Syntax Options Sample Output NOTE Sets the Ethernet MTU size to a s...

Страница 164: ...that can be used following a reboot ethViPortsSet Modifies the VIPORT count takes effect after the next reboot Syntax Options Sample Output NOTE Sets the VIPORT count to the specified value This is th...

Страница 165: ...cified ethernet port Syntax Options Sample Output NOTE Displays the current default user priority for an external Ethernet port The port parameter can be either a single port or a list of ports separa...

Страница 166: ...ault user priority for the specified virtual port Syntax Options Sample Output NOTE Displays the current default user priority for a specified virtual port The port parameter can be either a single po...

Страница 167: ...parameter can be either a single port or a list of ports separated by spaces and enclosed in double quotes ethExtStatsGet Displays statistics for a specified Ethernet port s Syntax Options ethVirtPri...

Страница 168: ...00000 0 Collisions 0x00000000 0 64 Octets 0x00000323 803 65 127 Octets 0x00000126 294 128 255 Octets 0x00000003 3 256 511 Octets 0x0000003f 63 512 1023 Octets 0x00000000 0 1024 1518 Octets 0x00000000...

Страница 169: ...tatsGet port port The virtual port s from which to have the statistics displayed ethVirtStatsGet 1 Current stats for virtual port 1 Incoming Broadcast Pkts 0x00000066 102 Multicast Pkts 0x00000017 23...

Страница 170: ...closed in double quotes vlanDot1qPvidSet View Set VLAN Dot1qPvid for a port Syntax Options NOTE Changes the default VLAN Dot1qPvid for a specified external Ethernet port Virtual Ethernet port or IOC t...

Страница 171: ...ands vlanDot1qPvid vlanMapMember vlanMapTaggedGet target instance target eth vi instance s port number vlanMapTaggedGet vi 56 vlanMapTaggedGet 0 vi 2 flag 0 Port 56 Total PVID 1 11 vlanMapTaggedGet et...

Страница 172: ...he VLAN PVID tagged map for Ethernet port s Related commands vlanDot1qPvid vlanMapMember vlanMapMemberGet Show VLAN PVID member map Syntax Options vlanMapTaggedSet target instance s pvid s flag 0 remo...

Страница 173: ...N PVID member map Syntax Options Sample Output vlanMapMemberGet vi 56 vlanMapMemberGet 0 vi 2 flag 0 Port 56 Total PVID 1 11 vlanMapMemberGet eth 1 vlanMapMemberGet 0 eth 1 flag 0 Port 1 Ext 1 Total P...

Страница 174: ...specified type The target parameter may be eth vi or all for external Ethernet ports virtual Ethernet ports or all ports respectively vlanMapInfo Display VLAN mapping information Syntax Options NOTE D...

Страница 175: ...rule s for Ethernet host port s Related commands vlanIngressRule vlanIngressFrame vlanDot1qPvid vlanEgressRuleGet target instance s target eth vi ioc instance s port number s IOC GUID vlanEgressRuleGe...

Страница 176: ...s for Ethernet host port s Related commands vlanIngressRule vlanIngressFrame vlanDot1qPvid vlanIngressRuleGet View Set VLAN Ingress rule s Syntax Options vlanEgressRuleSet target instance s flag 1 ena...

Страница 177: ...ss rule s Syntax Options NOTE Updates the VLAN Ingress rule flag for port s Ethernet port virtual port IOC GUID Related commands vlanEgressRule vlanIngressFrame vlanDot1qPvid vlanIngressRuleGet vi 56...

Страница 178: ...vlanDot1qPvid vlanIngressFrameSet View Set VLAN Ingress Frame type Syntax Options NOTE Updates the VLAN Ingress acceptable frame type for port s Ethernet port Vi Port IOC GUID Related commands vlanEgr...

Страница 179: ...s the maximum packet age in milliseconds for all LAN switches ethMaxPacketAgeSet View Set Ethernet maximum packet age Syntax Options Sample Output NOTE Sets the maximum packet age in milliseconds for...

Страница 180: ...ost host name guid ioc IOC number instance host interface instance s optional vlanGet name st130 1 0 vlanGet action 0 target 4 defVlan 1 admitAll 1 IOC 1 PVID 1 hostInst 0 Vi 81 HostGUID 0x0002c902002...

Страница 181: ...A 3 63 A vlanSet Set the VLAN configuration Syntax Options vlanSet type host ioc vlan pvid admit instance s type name guid host host name guid ioc IOC number vlan type default host pvid default PVID...

Страница 182: ...efVlan 1 admitAll 0 IOC 1 PVID 13 hostInst 0 Vi 81 HostGUID 0x0002c90200216e18 IOC 1 Inst 0 Name st130 ViPort DefPVID 13 EgressFilter yes IngressFilter yes IngressFrame tagged VLAN Map Membership 11 V...

Страница 183: ...1 0 vlanRem action 2 target 4 defVlan 1 admitAll 1 IOC 1 PVID 1 hostInst 0 Vi 81 HostGUID 0x0002c90200216e18 IOC 1 Inst 0 Name st130 ViPort DefPVID 1 EgressFilter no IngressFilter no IngressFrame all...

Страница 184: ...r the specified virtual port Syntax Options ethExtInfoGet 1 External Ethernet port 1 Alias Ext 1 Enabled 1 Mac Address 00 06 6a 00 45 50 MTU Size 1518 Default User Priority 2 Pvid 1 STP Port State 0 A...

Страница 185: ...Nic 1 Operator Status 2 Error No 0 External Ethernet port 6 Remote Host Types 0 MTU Size 1 Pvid 1 Default User Priority 0 Acceptable Frame Types 1 Ingress Filtering 2 Vi L2r Paths 0 Vi L2r Path Index...

Страница 186: ...00 b6 43 1G f 1G f Ext 2 Enbl enabled disabled Speed f full duplex h half duplex unknown ethVirtInfoTable type type 0 summary 1 vlan 2 host VI Swp VNIC Use LastHostName Inst Typ MTU MAC IOC Features...

Страница 187: ...Create a mirror between two Ethernet ports Syntax Options Sample Output ethExtMirrorGet port or ethExtMirrorGet port1 port2 ethExtMirrorGet 1 2 port External Ethernet port or list of ports to retriev...

Страница 188: ...ort is enabled or disabled Syntax Options Sample Output NOTE Displays the enabledstate forthe external Ethernet port The portparameter can be either a single port or a list of ports separated by space...

Страница 189: ...nclosed in double quotes ethExtDisable Disables the specified Ethernet port s Syntax Options Sample Output NOTE Disables the external Ethernet port The port parameter can be either a single port or a...

Страница 190: ...plays an overview of Lacp information for all external Ethernet ports The table contains the following information Port The external Ethernet port that this line refers to Link Link status for the por...

Страница 191: ...thernet port number as it is the only arguement In this case the output will be detailed information about the link aggregation status and configuration for the specified port ethExtLacpEnable Enables...

Страница 192: ...x Options Sample Output NOTE 802 3ad Lacp can be enabled or disabled on a per port basis This command displays information on the Lacp enabled state for all specified Ethernet ports The port parameter...

Страница 193: ...single port or a list of ports separated by spaces and enclosed in double quotes ethExtLacpKeySet Change the Lacp actor key for the specified External Ethernet port Syntax Options Sample Output Usage...

Страница 194: ...for the specified port s Syntax Options Sample Output NOTE Link aggregation can be configured on a per port basis to be determined automatically via 802 3ad Lacp or manually configured This command pr...

Страница 195: ...to the same switch and that the switch is also manually configured to have those ports in an aggregation Use aggregation index 0 to remove the port s from their respective manually configured aggrega...

Страница 196: ...ion failover will not be enabled and any remote hosts using that port will see the link status as down Aggregation failover is only relevant for ports in a manual or 802 3ad aggregation The default se...

Страница 197: ...ggregation failover will not be enabled and any remote hosts using that port will see the link status as down Aggregation failover is only relevant for ports in a manual or 802 3ad aggregation The def...

Страница 198: ...e or update the assignment of the virtual port to attach to a host Related commands ethVirtAssignedHostGet ethVirtAssignedHostRem ethVirtAssignedHostSet instance type host instance ioc instance port n...

Страница 199: ...commands ethVirtAssignedHostGet ethVirtAssignedHostSet ethExtAliasGet Display the alias currently assigned for the Ethernet port s Syntax Options Sample Output ethVirtAssignedHostRem instance s insta...

Страница 200: ...t s The port parameter can be either a single port or a list of ports separated by spaces and enclosed in double quotes ethVirtIgnoreVlanGet Allows the user to view the IGNORE VLAN flag for a host por...

Страница 201: ...Set Allows the user to set the IGNORE VLAN flag for a host port s Syntax Options Sample Output NOTE Set IGNORE VLAN flag for a host port The port parameter can be either a single port or a list of por...

Страница 202: ...parated by spaces and enclosed in double quotes ethVirtVnic2McastGet Reads if the Vnic2Mcast feature is enabled for a virtual port Syntax Options Sample Output ethVirtIgnoreVlanRem port s port s Host...

Страница 203: ...nic2McastRem Removes the Vnic2Mcast feature for a virtual port Syntax Options Sample Output NOTE A reboot is required to activate changes ethVirtVnic2McastSet portNumber portNumber The port that has t...

Страница 204: ...reboot The Vnic2McastMTU size must match the MTU size of the IB fabric ethVnic2McastMtuGet None ethVnic2McastMtuGet Link MTU for VNIC2 multicast groups 4 2048 ethVnic2McastMtuSet Vnic2McastMtu size Vn...

Страница 205: ...ed to activate changes ethVnic2McastRateGet None ethVnic2McastRateGet Link rate for VNIC2 multicast groups 3 4x or 10G ethVnic2McastRateSet Vnic2Mcast rate Vnic2Mcast rate The Vnic2Mcast rate setting...

Страница 206: ...y Note that the config directory is volatile and all contents will be lost on a reboot It is expected that the user will copy the configuration file off the device using FTP confFileCheck Validates a...

Страница 207: ...e to the system confFileList List contents of the config directory Syntax Options Sample Output NOTE List the contents of the config directory Note that the config directory is volatile all contents w...

Страница 208: ...ration file from the card to a remote FTP server The filename parameter is used as both the local filename and the filename to save the file as on the remote server filename The name of the file to di...

Страница 209: ...tion directory No validation of the configuration file is performed You will need to manually validate and then commit the config file for it s settings to take effect confFileRetrieve host user pass...

Страница 210: ...3 Virtual I O Command Line Interface Groups and Commands 3 92 D000025 002 Rev A S...

Отзывы: