General Description
Chassis Controls and LEDs
59268-00 A
1-3
A
Heartbeat LED (Green)
The Heartbeat LED indicates the status of the internal switch processor and the
results of the POST. Following a normal power-up, the Heartbeat LED blinks
about once per second to indicate that the switch passed the POST and that the
internal switch processor is running. In maintenance mode, the Heartbeat LED
illuminates continuously. Refer to
“Heartbeat LED Blink Patterns” on page 4-3
for
more information about Heartbeat LED blink patterns.
System Fault LED (Amber)
The System Fault LED illuminates to indicate that a fault exists in the switch
firmware or hardware. Fault conditions include POST errors, over-temperature
conditions, and power supply malfunctions. The Heartbeat LED shows a blink
code for POST errors and over temperature conditions. For more information,
refer to
“Heartbeat LED Blink Patterns” on page 4-3
.
Maintenance Button
The Maintenance button, shown in
Figure 1-2
, is a dual-function momentary
switch on the front panel. Its purpose is to reset the switch or to place the switch in
maintenance mode. Maintenance mode sets the IP address to 10.0.0.1 and
provides access to the switch for maintenance purposes when flash memory or
the resident configuration file is corrupted. Refer to
“Recovering a Switch Using
Maintenance Mode” on page 4-7
for more information.
Resetting a Switch
To reset the switch, press and hold the Maintenance button for less than 2
seconds. The switch will respond as follows:
1.
All the chassis LEDs will illuminate except the System Fault LED.
2.
After approximately 1 minute, the power-on self test (POST) begins,
extinguishing the Heartbeat LED.
3.
When the POST is complete, the Input Power LED is illuminated and the
Heartbeat LED is flashing once per second.
Placing the Switch in Maintenance Mode
To place the switch in maintenance mode, do the following:
1.
Isolate the switch from the fabric.
2.
Press and hold the Maintenance button with a pointed tool for a few seconds
until only the Heartbeat LED is illuminated. Continue holding the
maintenance button until the Heartbeat LED extinguishes, then release the
button. The Heartbeat LED illuminates continuously while the switch is in
maintenance mode.
To exit maintenance mode and return to normal operation, press and release the
Maintenance button momentarily to reset the switch.
Содержание SANbox 3810
Страница 1: ...59268 00 A SANbox 3810 Fibre Channel Switch Installation Guide Firmware Version 7 4...
Страница 8: ...viii 59268 00 A SANbox 3810 Fibre Channel Switch Installation Guide S Notes...
Страница 34: ...General Description Switch Management 1 10 59268 00 A S Notes...
Страница 44: ...Planning Fabric Management 2 10 59268 00 A S Notes...
Страница 62: ...Installation Installing Firmware 3 18 59268 00 A S Notes...
Страница 90: ...SANbox 3810 Fibre Channel Switch Installation Guide Index 6 59268 00 A S Notes...
Страница 91: ......