Installation
Installing a Switch
3-10
59268-00 A
S
To power up a SANbox 3810 switch, connect the power cord to the AC power
receptacle on the back of the switch chassis and to a grounded AC outlet.
The switch responds in the following sequence:
1.
The chassis LEDs (Input Power, Heartbeat, System Fault) illuminate
followed by all port Logged-In LEDs.
2.
After a couple seconds the System Fault LED is extinguished while the Input
Power LED and Heartbeat LED remain illuminated.
3.
After approximately one minute, the POST executes and the Heartbeat LED
is extinguished.
4.
After about another minute, the POST is complete, all LEDs are
extinguished except the Input Power LED and the Heartbeat LED:
The Input Power LED remains illuminated indicating that the switch
logic circuitry is receiving DC voltage. If not, contact your authorized
maintenance provider.
The Heartbeat LED indicates the results of the POST. The POST tests
the condition of firmware, memories, data-paths, and switch logic
circuitry. If the Heartbeat LED blinks steadily about once per second,
the POST was successful, and you can continue with the installation
process. Any other blink pattern indicates that an error has occurred.
Refer to
“Heartbeat LED Blink Patterns” on page 4-3
for more
information about error blink patterns.
Содержание SANbox 3810
Страница 1: ...59268 00 A SANbox 3810 Fibre Channel Switch Installation Guide Firmware Version 7 4...
Страница 8: ...viii 59268 00 A SANbox 3810 Fibre Channel Switch Installation Guide S Notes...
Страница 34: ...General Description Switch Management 1 10 59268 00 A S Notes...
Страница 44: ...Planning Fabric Management 2 10 59268 00 A S Notes...
Страница 62: ...Installation Installing Firmware 3 18 59268 00 A S Notes...
Страница 90: ...SANbox 3810 Fibre Channel Switch Installation Guide Index 6 59268 00 A S Notes...
Страница 91: ......