3 – Getting Started
D000006-000 Rev A
3-7
Q
a. When Virtual I/O controllers (VIC) are installed in a chassis, each VIC should
also be assigned a unique name.
4.
(Switch)
Configure the administrator password on each SilverStorm Chassis
NOTE:
Newer versions of SilverStorm chassis firmware permit SSH keys to be
configured within the chassis for secure password-less login. In this case
it is recommended to configure SSH keys in the chassis at this point such
that the IB Management Node can login as admin without a password.
NOTE:
When using versions of SilverStorm chassis firmware that do not support
SSH keys, to simplify the use of Fast Fabric it is recommended to install
all chassis with the same admin password.
5.
(Switch)
Mount or copy the relevant chassis firmware CD(s) or files onto the
Fast Fabric management node. During the steps below the *.pkg files on the
CD will be used to upgrade the firmware on each chassis.
NOTE:
When copying files its best to place all files at a given firmware level into
a single directory whose name indicates the firmware revision number
Once the above steps have been completed, additional setup of the Chassis may
be performed using Fast Fabric.
1.
(Switch)
Select the "Chassis Admin via Fast Fabric" option from the main menu.
2.
(Switch)
Select the items shown as "Perform" in the menu below and press
the P key to perform them:
SilverStorm Technologies Inc. IB Chassis Admin Menu (4.1.1.0.15)
Fast Fabric Chassis List: /etc/sysconfig/iba/chassis
0) Edit Config and Select/Edit Chassis Files [
Perform
]
1) Verify Chassis via Ethernet ping [
Perform
]
2) Update Chassis Firmware [
Perform
]
3) Show Status of Chassis IB Ports [ Skip ]
4) Reboot Chassis [ Skip ]
5) Generate all Chassis Problem Report Info [ Skip ]
6) Run a command on all chassis [ Skip ]
7) View ibtest result files [ Skip ]
P) Perform the selected actions
N) Select None
X) Return to Previous Menu (or ESC)
3.
(Switch)
"Edit Config and Select/Edit Chassis Files" will permit the chassis and
fastfabric.conf files to be edited. When placed in the editor for fastfabric.conf,
review all the settings. Especially review the
FF_CHASSIS_LOGIN_METHOD
Содержание Fast Fabric
Страница 1: ...D000006 000 Rev A Page i Q S i m p l i f y Fast Fabric Users Guide...
Страница 2: ...Fast Fabric Users Guide Q Page ii D000006 000 Rev A...
Страница 38: ...3 Getting Started Upgrading IB software 3 24 D000006 000 Rev A Q...
Страница 148: ...6 MPI Sample Applications Pallas 6 6 D000006 000 Rev A Q...
Страница 159: ...B Fast Fabric Configuration Files D000006 000 Rev A B 7 Q NOTE Do not edit etc sysconfig iba iba_mon conf sample...
Страница 166: ...B Fast Fabric Configuration Files Port List Files B 14 D000006 000 Rev A Q...
Страница 168: ...C Configuration of IPoIB Name Mapping C 2 D000006 000 Rev A Q...