B – Fast Fabric Configuration Files
Selection of slots within a chassis
B-10
D000006-000 Rev A
Q
# this is a comment
192.168.0.5# chassis IP address
edge1# chassis resolvable TCP/IP name
include /etc/sysconfig/iba/corechassis# included file
Each line of the chassis list file may specify a single chassis, a comment or another
chassis list file to include.
Chassis may be specified by chassis management network IP address or a
resolvable TCP/IP name. Typically, names are used for readability.
Files to be included may be specified via an
include
directive followed by a file
name. File names specified should generally be absolute path names. If relative
path names are used, they will be searched for within the current directory then
/etc/sysconfig/iba
.
Comments may be placed on any line by using a
#
to precede the comment. On
lines with chassis or include directives, the
#
must be white-space separated from
any preceding name, IP address or included filename.
B.5
Selection of slots within a chassis
Normally, operations are performed against the management card in the chassis.
For operations such as
cmdall
, the command is executed against the management
interface for the given chassis. For more sophisticated operations, such as firmware
update, a directory with firmware for each chassis card type can be supplied and
all cards in the chassis will be updated with the appropriate firmware from that
directory.
However, in some cases it may be desirable to perform operations against a specific
subset of cards within the chassis. In this case the chassis IP address, name within
a chassis list or a chassis file can be augmented with a list of slot numbers to operate
on. This is done in the form:
chassis:slot1,slot2,…
For example:
i9k229:0
i9k229:0,1,5
192.168.0.5:0,1,5
NOTE:
There must be no spaces within the chassis name and/or slot list.
This format is used by
cmdall
and
chassis firmware update
. This format
may be used anywhere a chassis name or IP address is valid, such as the
-H
option,
the
CHASSIS
environment variable or
chassis list files
. The slot number
specified is ignored on some operations (such as
pingall
). Only slots containing
management cards, EVICs and FVICs may be specified with this format. For all
Содержание Fast Fabric
Страница 1: ...D000006 000 Rev A Page i Q S i m p l i f y Fast Fabric Users Guide...
Страница 2: ...Fast Fabric Users Guide Q Page ii D000006 000 Rev A...
Страница 38: ...3 Getting Started Upgrading IB software 3 24 D000006 000 Rev A Q...
Страница 148: ...6 MPI Sample Applications Pallas 6 6 D000006 000 Rev A Q...
Страница 159: ...B Fast Fabric Configuration Files D000006 000 Rev A B 7 Q NOTE Do not edit etc sysconfig iba iba_mon conf sample...
Страница 166: ...B Fast Fabric Configuration Files Port List Files B 14 D000006 000 Rev A Q...
Страница 168: ...C Configuration of IPoIB Name Mapping C 2 D000006 000 Rev A Q...