Unit does not turn on when
pressing ON/OFF button
The Unit has a 3-minute protection feature that prevents the unit from over-
loading. The unit cannot be restarted within three minutes of being turned
off.
The unit changes from COOL/
HEAT mode to FAN mode
The unit may change its setting to prevent frost from forming on the unit.
Once the temperature increases, the unit will start operating in the previ-
ously selected mode again.
The set temperature has been reached, at which point the unit turns off the
compressor. The unit will continue operating when the temperature fluctu-
ates again.
The indoor unit emits white mist In humid regions, a large temperature difference between the room’s air
and the conditioned air can cause white mist.
Both the indoor and outdoor
units emit white mist
When the unit restarts in HEAT mode after defrosting, white mist may be
emitted due to moisture generated from the defrosting process.
The indoor unit makes noises
A rushing air sound may occur when the louver resets its position.
A squeaking sound may occur after running the unit in HEAT mode due to
expansion and contraction of the unit’s plastic parts.
Both the indoor unit
and outdoor unit
make noises
Low hissing sound during operation: This is normal and is caused by refrige-
rant gas flowing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is
defrosting: This noise is normal and is caused by the refrigerant gas stopping
or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal
parts caused by temperature changes during operation can cause squeaking
noises.
The outdoor unit makes noises
The unit will make different sounds based on its current operating mode.
Dust is emitted from either the
indoor or outdoor unit
The unit may accumulate dust during extended periods of nonuse, which
will be emitted when the unit is turned on. This can be mitigated by cove-
ring the unit during long periods of inactivity.
The unit emits a bad odor
The unit may absorb odors from the environment (such as furniture, cook-
ing, cigarettes, etc.) which will be emitted during operations.
The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor unit does
not operate
During operation, the fan speed is controlled to optimize product operation.
Operation is erratic, unpredicta-
ble, or unit is unresponsive
Interference from cell phone towers and remote boosters may cause the unit
to malfunction. In this case, try the following:
•
Disconnect the power, then reconnect.
•
Press ON/OFF button on remote control to restart operation.
G
NOTE!
If problem persists, contact a local dealer or your nearest customer service center. Provide them
with a detailed description of the unit malfunction as well as your model number.
4
man_S70xx ('21) V1.indd 62
man_S70xx ('21) V1.indd 62
08-11-2021 18:08
08-11-2021 18:08
Содержание S 7035
Страница 33: ...33 6 man_S70xx 21 V1 indd 33 man_S70xx 21 V1 indd 33 08 11 2021 18 08 08 11 2021 18 08...
Страница 65: ...65 4 man_S70xx 21 V1 indd 65 man_S70xx 21 V1 indd 65 08 11 2021 18 08 08 11 2021 18 08...
Страница 97: ...97 u man_S70xx 21 V1 indd 97 man_S70xx 21 V1 indd 97 08 11 2021 18 08 08 11 2021 18 08...
Страница 129: ...129 man_S70xx 21 V1 indd 129 man_S70xx 21 V1 indd 129 08 11 2021 18 08 08 11 2021 18 08...