2
S80AS
S80AS
84
127
43
72
113
10
5
50
60
88
4-Ø4 HOLES
Ø8 CABLE ENTRY
Ø83
•
Power Wiring : In case of terminal type, power lines are
connected to the terminals.
• This product can be wired regardless of polarity.
• For built-in buzzer type, there is a shared supply line for the
buzzer and lighting element.
Lens(AS)
Housing(ABS)
Xenon bulb
S80AS
Wiring Instructions
Dimensions
(Units : mm)
Parts Definition/ Installation/ Mounting Hole Specifications
Xenon Bulb Replacement Instructions
■ Parts Definition/ Installation
• Machine holes on the mounting surface referring to the
diagram below.
■ Mounting Hole Specifications
• Please wait at least 30 minutes after turning off the power before replacing the
xenon bulb.
• Please pull out the entire xenon bulb structure
①
to disassemble.
• For xenon bulb assembly, please ensure the connector portion of the xenon
bulb structure matches the pin location
②
.
Disassemble
bulb
Assemble
bulb
Power
Fuse
50
60
4-Ø4.5 HOLES
Min. Ø5 CABLE ENTRY
①
②
DC/AC