Software function blocks Pallet dispenser PD1 - SIEMENS
12
5.7
Function block outputs
Outputs must be declared by the integrator.
Outputs provide feedback such as faults, status and communication.
Tabel 05:
Outputs pallet dispenser PD1
Naming
Data
type
Unit
Description
oY4
Bool
0/1
Valve movement up
oY12
Bool
0/1
Valve movement down
oY6
Bool
0/1
Valve movement forks in pallet
oY14
Bool
0/1
Installation is in manual mode. Manual commands influence the
direction of rotation.
oAlarmUpDown
Bool
0/1
Alarm time duration up/down movement.
Time exceeded time limit in settings
oAlarmForks
Bool
0/1
Alarm time duration fork movement
Time exceeded time limit in settings
oAlarmPosition
Bool
0/1
Alarm undetected position.
Put dispenser manually back in basic position
Upper position (B1), forks in pallet stack (B5)
oAlarmEmpty
Bool
0/1
Alarm depot empty
Refill depot
oAlarmAlmostEmpty Bool
0/1
Alarm depot almost empty
Refill depot