Software function blocks Pallet dispenser PD1 - SIEMENS
22
9
Pneumatic circuit diagram
Mechanical actuated valve 563390 ensures that there’s no danger of possible constriction when the
carrier is in its lowest position with lifting arms closed in case of lack of air pressure.
Air consumption at 6 bar with 120 pallets/hour is 20m³. With a different capacity, the air
consumption can be calculated accordingly, or contact and check with Qimarox.
CAUTION
Safety decals regarding switching off air pressure and venting cylinders need to
be present and clearly visible on all three cylinders. Do not use machine if