Software function blocks Pallet dispenser PD1 - SIEMENS
16
6.4
Function block settings
The settings consist of one UDT
“Settings_Palletdispenser_PD1”
Everything can/will be determined from the Qimarox configuration sheet.
We strongly recommend using the PDF configuration sheets provided by Qimarox for this.
Tabel 07:
Settings pallet dispenser PD1
Naming
Data
type
Unit
Description
Configuration.Mode
Int
1..2
1 = Start position upper position (Basic position)
2 = Start position bottom position (Wait position)
Configuration.Pallettype
Int
1..99
Actual pallettype in dispenser, this must match the
pallettype requested when using de-stacking
Configuration.Double
Bool
0/1
0 = single pallet sensor (B2)
1 = double pallet sensor (B10)
MaximumDurationUpDown
Int
ms.
Maximum duration of movement before creating alarm
MaximumDurationForks
Int
ms.
Maximum duration of movement before creating alarm
6.5
Function block handshake
The handshake structure consists of one UDT
“Handshakes_PalletDispenser_PD1”
This enables the other equipment to communicate and control with the pallet dispenser
Tabel 08:
Handshake pallet dispenser PD1
Naming
Data
type
Unit
Description
Command.Receive
Bool
0/1
TRUE = Request to receive a pallet (Stacking)
Keep this command set to TRUE until pallet dispenser gives status
“Busy”
Status.Blocked
Bool
0/1
TRUE = Alarm active OR not in right step
Status.PalletPresent
Bool
0/1
TRUE = Sensor pallet present (B7)
Status.BasicPosition
Bool
0/1
TRUE = Upper position (B1), forks in pallet stack (B5)
Status.WaitPosition
Bool
0/1
TRUE = Bottom position (B3) ,forks out of pallet stack (B13)
Status.Busy
Bool
0/1
TRUE = Busy with cycle
Status.Pallettype
Int
1..99 Actual pallet type
Status.Step
Int
1..20 Actual step number