The picture below shows a typical defect column with low CTE or zero CTE. This is a defect column. You 
have to use the some defect tools to remove it. 
 

8. How to use the QHYOAG that the camera comes with? 

QHYOAG-S and a M42 adapter come with the QHY90A. By six M3 screws you can install them. 
The prism of the OAG may have a protect film on front surface. Please remove it before using. 
You can use QHY5L-II-M as the guider. Please pay attention that you may remove the front part of QHY5L-
II-M to get the back focus short enough for this combination of OAG-S and QHY90A. If you are using other 
guider. We are not guarantee the back focus is suitable for  them due to the very short back focus of the 
QHY90A. 
The thickness of QHYOAG-S is 10mm and the M42 adapter  is 3mm. So the totally back focus addon is 
13mm. The QHY90A back focus is 33mm. So the total back focus with QHYOAG-S is 46mm.

  

 
9.

 

Camera Maintenance 

Drying the CCD Chamber 
The CCD sensor is located in a CCD chamber. This chamber is airproof and connect to the socket of the 
silicone gel tube (drying tube) on one side of the case. If there is moisture and it causes the CCD sensor 
glass to get dew. You can use the silicone gel tube (drying tube) included in the package to dry it. 
  
Please put the effective silicone gel into the silicone gel tube. Make sure to put a small amount of cotton 
inside to prevent the silicone gel get into the CCD chamber. 
  
The process of drying usually needs 24 hours. 
Avoid CCD chamber optic window get dew 
If the environment humidity is very high, the optic window of the CCD chamber may get dew. The QHY90A 
has the build-in heat board on this optic window to heat the optic window to avoid it. In most conditions it 
can take effect. 
If the optic window still get dew please try the following method. 
 
1. Avoid directing the camera to the ground. The density of the cold air is greater than the density of the hot 
air. If the camera is facing down to the ground, the cold air will more easily contact the glass and cause it to 
cool down and condense. 
2. Increase the temperature of the CMOS sensor. You can increase the temperature of the CMOS sensor 
slightly to prevent fogging of the glass. 
3. Check whether the heating plate is working. If the heating plate is not working, the glass will be easily 
fogged. Generally, the temperature of the heating plate can reach 65-

70 ° C in a 25 ° C environment. If it is 

not so hot, it may be because the heating plate is damaged, you can contact us to replace the heating plate. 

Содержание QHY90A

Страница 1: ...QHY90A All in one COLDMOS Astronomy Camera User Manual REV 1 0...

Страница 2: ...2 SOFTWARE INSTALLATION 4 03 FILTER INSTALLATION 5 04 USE QHY90A WITH ASCOM 6 05 USE QHY90A IN EZCAP_QT 13 06 USE QHY90A IN FIRECAPTURE 16 07 PERIPHERAL PORTS ON QHY90A 17 08 FAQ 19 09 OHY90A MECHANIC...

Страница 3: ...tube 1 Desiccant 1 USB hub bypass board 1 Screw driver for M2 hexagon screw 1 Screw driver for M3 hexagon screw 1 Screws for fixing filter frame and filter many Inspection report 1 White carton 1 OHYO...

Страница 4: ...put port and use the other one as a power output port for other devices that need 12V power supply Turn the switch on For the first time the system will find a new device and search the driver You can...

Страница 5: ...filters do not touch the top cap and photoelectric position detector 3 After you ve finished installing the filters you can turn on the camera and connect the camera to your PC with USB cable to make...

Страница 6: ...ection Please note that QHY90A always transfers maximum bit depth by ASCOM to make the best DSO imaging performance The image format is 16bit width and patch zero on low bit MAXIMDL 1 First you have t...

Страница 7: ...in 15 and offset 132 to start Keep clicking Okay to return to Camera Control window 4 The following instructions are going to show you how to configure the built in filter wheel in MAXIMDL Click Setup...

Страница 8: ...QHY90A 8...

Страница 9: ...QHY90A 9 4 The following instructions are going to show you how to configure the built in filter wheel in MAXIMDL Click Setup Filter in the Camera Control window...

Страница 10: ...aging needs After you connect your gears and configure Sequence Generator Pro properly you can go to sleep and see images in the morning To use QHY90A in Sequence Generator Pro you can follow the inst...

Страница 11: ...QHY90A 11 3 Click the wrench icon to set up your camera 4 Select QHYCCD FilterWheel click the Chain icon to connect...

Страница 12: ...lugged in the 12V power supply cable and the initialization of filter wheel has been finished For more information you can check its tutorials on the Help tab NB Since Sequence Generator Pro is based...

Страница 13: ...4 Before you click connect make sure you can see QHY90A in the device manager on Windows Sometimes if you click connect you may see the warning shown in the picture below That doesn t necessarily mea...

Страница 14: ...ich filter you are going to use by changing the position of filter wheel as shown in the following picture 7 You can use the preview tab to do preview And use the focus tools to do focus Then use the...

Страница 15: ...QHY90A 15 8 In EZCAP_QT there is a planner for image tasking You can capture a series images by using the table below...

Страница 16: ...s folder After it was installed successfully navigate to Document folder and you will find its installation folder as shown below Enter that folder and run FireCapture exe then select QHYCCD camera An...

Страница 17: ...types of serial port cable You can contact QHYCCD to know if there s serial port cable you need The pin arrangement is already shown in the picture above Trigger ports There are a trigger in port lef...

Страница 18: ...d of the internal circuit it s recommended to reduce the use of current QHY A series Cameras have a USB hub board in them And these two USB type A ports along with these two serial ports aforementione...

Страница 19: ...backfire Besides during the process of cleaning you may scratch the CCD and you may damage the internal circuit when you open the camera QHYCCD provides CCD clean service The cleaning fee is 100 USD p...

Страница 20: ...QHY90A 20 You will see the power PCB board Remove the two screw of the power PCB board Remove the three cable carefully...

Страница 21: ...ber is connecting with the silicone gel tube socket by a rubber pipe Remove the two screw for the silicone gel socket Remove the four screw for the CCD chamber There is totally eight screws for the CC...

Страница 22: ...Now the CCD chamber is removed The CCD sensor can be clean here The CCD sensor has the AR coating Please clean it carefully by using the lens paper or another professional tools like the DLSR sensor c...

Страница 23: ...hing at all based on different application programs Currently all application program don t support this display please wait for latest application program that supports this display 7 What is defect...

Страница 24: ...ss to get dew You can use the silicone gel tube drying tube included in the package to dry it Please put the effective silicone gel into the silicone gel tube Make sure to put a small amount of cotton...

Страница 25: ...QHY90A 25 09 OHY90A Mechanical Size Mechanical drawing without OAG S...

Страница 26: ...QHY90A 26...

Страница 27: ...QHY90A 27 Mechanical drawing with OAG S...

Страница 28: ...QHY90A 28...

Страница 29: ...TBD Binning 1x1 2x2 4x4 Exposure Time 1ms 10000sec TEC 2 stage Cooling Typical 45 below Ambient temperature Shutter Butterfly Mechanical Shutter with Uniform illumination Moisture Control Air Connect...

Отзывы: