5.

 

How to protect the cooler in QHY90A?

 

The cooler in QHY90A can lower the CCD temperature to a value that's almost 40 degrees centigrade below 
the ambient temperature. So you need to be careful to avoid thermal shock, which refers to when the cooler's 
temperature rises  or fall  dramatically,  the  cooler  is  subjected to  strong  internal  stress  due to  contraction 
principle. Drastic thermal shock can shorten cooler's service life or permanently break it. 
So when you begin to adjust the CCD temperature, you should avoid setting "Cooler Power" to its maximum 
value,  and  you  should  gradually  turn  up  the  "Cooler  Power"  value.  When  you  turn  off  the  power,  if  the 
"Cooler  Power"  value  is  very  big,  you  should  gradually  turn  it  down  before  turn  off  the  power. 
  

6.

 

What's small display on the camera for?

 

The  OLED  display  is  used  for  display  certain  formation  related  to  the  shooting.  It  is  directly  driven  by 
application  program.  So  it  may  display  different  information  or  doesn't  display  anything  at  all  based  on 
different application programs. Currently all application program don't support this display, please wait for 
latest application program that supports this display. 
 

7. What is defect columns?

 

You may see one or more vertical columns whose top pixel is a bright dot. Normally speaking such columns 
are not defect column. It is resulted from one pixel with high thermal current. All the pixels below that pixel 
will be affected by it as thermal current is transferred through that pixel. 
  
This pixel can be removed by dark frame calibration. If they cannot be eliminated entirely, you can solve 
this  problem  by  using  some  astronomical  image  processing  software.  These  software  will  replace  that 
column with the average value of its surrounding columns. 
  
Aside from  the  columns we  just  talked  about,  you  may  see  one  or more black  columns  which  is  not full 
sensitive to the light or it is dim to light. This is the defect column and it cannot be removed by dark frame 
calibration. 
  
The following image shows a typical "defect" columns caused by a hot pixel, which is not very bright and it 
is usually not considered as a defect column. It will be gone after dark frame calibration.

  

 
 

Содержание QHY90A

Страница 1: ...QHY90A All in one COLDMOS Astronomy Camera User Manual REV 1 0...

Страница 2: ...2 SOFTWARE INSTALLATION 4 03 FILTER INSTALLATION 5 04 USE QHY90A WITH ASCOM 6 05 USE QHY90A IN EZCAP_QT 13 06 USE QHY90A IN FIRECAPTURE 16 07 PERIPHERAL PORTS ON QHY90A 17 08 FAQ 19 09 OHY90A MECHANIC...

Страница 3: ...tube 1 Desiccant 1 USB hub bypass board 1 Screw driver for M2 hexagon screw 1 Screw driver for M3 hexagon screw 1 Screws for fixing filter frame and filter many Inspection report 1 White carton 1 OHYO...

Страница 4: ...put port and use the other one as a power output port for other devices that need 12V power supply Turn the switch on For the first time the system will find a new device and search the driver You can...

Страница 5: ...filters do not touch the top cap and photoelectric position detector 3 After you ve finished installing the filters you can turn on the camera and connect the camera to your PC with USB cable to make...

Страница 6: ...ection Please note that QHY90A always transfers maximum bit depth by ASCOM to make the best DSO imaging performance The image format is 16bit width and patch zero on low bit MAXIMDL 1 First you have t...

Страница 7: ...in 15 and offset 132 to start Keep clicking Okay to return to Camera Control window 4 The following instructions are going to show you how to configure the built in filter wheel in MAXIMDL Click Setup...

Страница 8: ...QHY90A 8...

Страница 9: ...QHY90A 9 4 The following instructions are going to show you how to configure the built in filter wheel in MAXIMDL Click Setup Filter in the Camera Control window...

Страница 10: ...aging needs After you connect your gears and configure Sequence Generator Pro properly you can go to sleep and see images in the morning To use QHY90A in Sequence Generator Pro you can follow the inst...

Страница 11: ...QHY90A 11 3 Click the wrench icon to set up your camera 4 Select QHYCCD FilterWheel click the Chain icon to connect...

Страница 12: ...lugged in the 12V power supply cable and the initialization of filter wheel has been finished For more information you can check its tutorials on the Help tab NB Since Sequence Generator Pro is based...

Страница 13: ...4 Before you click connect make sure you can see QHY90A in the device manager on Windows Sometimes if you click connect you may see the warning shown in the picture below That doesn t necessarily mea...

Страница 14: ...ich filter you are going to use by changing the position of filter wheel as shown in the following picture 7 You can use the preview tab to do preview And use the focus tools to do focus Then use the...

Страница 15: ...QHY90A 15 8 In EZCAP_QT there is a planner for image tasking You can capture a series images by using the table below...

Страница 16: ...s folder After it was installed successfully navigate to Document folder and you will find its installation folder as shown below Enter that folder and run FireCapture exe then select QHYCCD camera An...

Страница 17: ...types of serial port cable You can contact QHYCCD to know if there s serial port cable you need The pin arrangement is already shown in the picture above Trigger ports There are a trigger in port lef...

Страница 18: ...d of the internal circuit it s recommended to reduce the use of current QHY A series Cameras have a USB hub board in them And these two USB type A ports along with these two serial ports aforementione...

Страница 19: ...backfire Besides during the process of cleaning you may scratch the CCD and you may damage the internal circuit when you open the camera QHYCCD provides CCD clean service The cleaning fee is 100 USD p...

Страница 20: ...QHY90A 20 You will see the power PCB board Remove the two screw of the power PCB board Remove the three cable carefully...

Страница 21: ...ber is connecting with the silicone gel tube socket by a rubber pipe Remove the two screw for the silicone gel socket Remove the four screw for the CCD chamber There is totally eight screws for the CC...

Страница 22: ...Now the CCD chamber is removed The CCD sensor can be clean here The CCD sensor has the AR coating Please clean it carefully by using the lens paper or another professional tools like the DLSR sensor c...

Страница 23: ...hing at all based on different application programs Currently all application program don t support this display please wait for latest application program that supports this display 7 What is defect...

Страница 24: ...ss to get dew You can use the silicone gel tube drying tube included in the package to dry it Please put the effective silicone gel into the silicone gel tube Make sure to put a small amount of cotton...

Страница 25: ...QHY90A 25 09 OHY90A Mechanical Size Mechanical drawing without OAG S...

Страница 26: ...QHY90A 26...

Страница 27: ...QHY90A 27 Mechanical drawing with OAG S...

Страница 28: ...QHY90A 28...

Страница 29: ...TBD Binning 1x1 2x2 4x4 Exposure Time 1ms 10000sec TEC 2 stage Cooling Typical 45 below Ambient temperature Shutter Butterfly Mechanical Shutter with Uniform illumination Moisture Control Air Connect...

Отзывы: