QHY27/28/29M
21
8 Camera Maintenance
Drying the CCD Chamber
The CCD sensor is located in a CCD chamber. This chamber is airproof and connect to the socket of
the silicone gel tube on one side of the QHY29M front case. If there is moisture and cause the CCD
sensor glass get dew. You can connect the silicone gel tube on the socket to dry it.
Please put the effective silicone gel into the silicone gel tube. Make sure there is a small amount of
cotton inside to prevent the silicone gel get into the CCD chamber.
Avoid CCD chamber optic window get dew
If the environment humidity is very high, the optic window of the CCD chamber may get dew. The
QHY29M has the build-in heat board on this optic window to heat the optic window to avoid it. In
most conditions it can take effect.
If the optic window still get dew please try the following method.
1. Avoid the CCD Camera face down to ground. The cold air is heavy than warm air, if you put the
camera facing down to the ground, the cold air is easy to get the optic window and cause it very
cold and get dew
2. Increase the temperature of the CCD sensor. You can increase the CCD sensor temperature a
little to prevent the optic window get dew.
3. Check if the heat board working. If the heat board not working, the optic window is easy to get
dew. Normally the heat board can get about 65-70C in +25C environment. If it is not so warm, it
maybe the problem of the heat board damaged. Need to contact QHYCCD to replace one heat
board.
Содержание QHY27M
Страница 1: ...Super high resolution cooled astronomical camera QHY27 28 29M User s Manual Rev 1 0...
Страница 12: ...QHY27 28 29M 9...
Страница 14: ...QHY27 28 29M 11...
Страница 18: ...QHY27 28 29M 15...
Страница 26: ...QHY27 28 29M 23 10 Mechanical Dimensions...
Страница 27: ...QHY27 28 29M 24 drawing of QHY29M The back focal length of QHY29M is about 18 5 mm...
Страница 28: ...QHY27 28 29M 25...
Страница 30: ...QHY27 28 29M 27...