Before you Begin
1. Check the mains water pressure. The pressure must
not be below 1.5 BAR (22 psi) or above 5 BAR (73 psi),
measured during a low demand period – (mid-morning or
mid-afternoon).
If the pressure exceeds 5 BAR a pressure reducing valve
must be installed in the cold mains supply to protect both
the boiler and the water filter housing. A suitable pressure
reducing valve can be purchased at www.grldirect.co.uk/
franke
2. The unit must be installed in a frost free environment.
3. Ensure that the cabinet is well ventilated. If in doubt it is
advisable to improve the circulation of air by drilling some
holes in the top and bottom of the rear panel.
4. Be careful when making the connections to the chiller.
Do not be tempted to over-tighten the connections. It is
only necessary to firmly hand tighten the nuts using the
patented NutRunna® plastic tightening devices provided to
make a secure watertight seal.
5. Shut off the mains water supply.
6. Switch off the mains electricity supply at the socket.
7. Covering the chiller will cause it to overheat, affecting its
performance and potentially causing it to shut down.
8. Ensure that the chiller is seated on a flat surface, well
ventilated and not in direct sunlight.
9. A kitchen base unit not less than 800mm wide, good
ventilation within the cabinet to allow cooling of the chiller
unit.
Where possible you should provide a vent in the base and
one near the top of the cabinet to allow air to flow. You
must provide a 75mm air gap on all sides of the cooler unit.
Introduction
Thank you for purchasing this QETTLE Chiller system. Correctly installed and properly maintained in
accordance with the following instructions, it will provide you with reliable service for many years. This
guide explains how to install a new water chiller system.
Warranty
This product is a water chilling device intended for domestic use only. The water supply pressure must be
between minimum 1.5 BAR (22 psi) maximum 5 BAR (73 psi).
Description
Value
Unit
Dimensions
180w x 320h
x 370d
mm
Load
10
Amps
Voltage
230
Volts
Power
(Compressor)
160
Watts
Min Water
Pressure
1.5
Bar
Max Water
Pressure
5
Bar
Cooling Time 20
Mins
Recovery
Time
15
Mins
Tank
Capacity
1.2
Litres
Dispensing
Temperature
3-6
˚C
Dispensing
Capacity at
4 ˚C - 10 ˚C
0.9
Litres
Weight
12
Kg
Refrigerant
R-134A
N/A
Decibel Rating
38
dB
Component List
1. Water Chiller (x1)
2. Inlet Hose - Red identification (x1)
3. Outlet Hose - Blue identification (x1)
4. 3/8” Straight JG Push Fit Connector (x2)
5. 3/8”-1/4” Straight JG Push Fit
Connector (x2)