background image

Before you Begin 

1. Check the mains water pressure. The pressure must 

not be below 1.5 BAR (22 psi) or above 5 BAR (73 psi), 

measured during a low demand period – (mid-morning or 

mid-afternoon). 

 

 

If the pressure exceeds 5 BAR a pressure reducing valve 

must be installed in the cold mains supply to protect both 

the boiler and the water filter housing. A suitable pressure 

reducing valve can be purchased at www.grldirect.co.uk/

franke

2. The unit must be installed in a frost free environment. 

3. Ensure that the cabinet is well ventilated. If in doubt it is 

advisable to improve the circulation of air by drilling some 

holes in the top and bottom of the rear panel. 

4. Be careful when making the connections to the chiller. 

Do not be tempted to over-tighten the connections. It is 

only necessary to firmly hand tighten the nuts using the 

patented NutRunna® plastic tightening devices provided to 

make a secure watertight seal.

 

5. Shut off the mains water supply.

6. Switch off the mains electricity supply at the socket.

7. Covering the chiller will cause it to overheat, affecting its 

performance and potentially causing it to shut down. 

8. Ensure that the chiller is seated on a flat surface, well 

ventilated and not in direct sunlight. 

9. A kitchen base unit not less than 800mm wide, good 

ventilation within the cabinet to allow cooling of the chiller 

unit.  

 

Where possible you should provide a vent in the base and 

one near the top of the cabinet to allow air to flow. You 

must provide a 75mm air gap on all sides of the cooler unit.

Introduction

Thank you for purchasing this QETTLE Chiller system.  Correctly installed and properly maintained in 

accordance with the following instructions, it will provide you with reliable service for many years. This 

guide explains how to install a new water chiller system.   

Warranty

This product is a water chilling device intended for domestic use only. The water supply pressure must be 

between minimum 1.5 BAR (22 psi) maximum 5 BAR (73 psi).

Description

Value

Unit  

Dimensions

180w x 320h 

x 370d

mm

Load

10

Amps

Voltage

230

Volts

Power

(Compressor)

160

Watts

Min Water 

Pressure

1.5

Bar

Max Water 

Pressure

5

Bar

Cooling Time 20

Mins

Recovery 

Time

15

Mins

Tank 

Capacity

1.2

Litres

Dispensing 

Temperature

3-6

˚C

Dispensing 

Capacity at 

4 ˚C - 10 ˚C

0.9

Litres

Weight

12

Kg

Refrigerant

R-134A

N/A

Decibel Rating

38

dB

Component List

1. Water Chiller (x1)

2. Inlet Hose - Red identification (x1)

3. Outlet Hose - Blue identification (x1)

4. 3/8” Straight JG Push Fit Connector (x2)

5. 3/8”-1/4” Straight JG Push Fit  

Connector (x2)