background image

OPERATING MANUAL 

 
 
 

 

Blast chiller - freezer 

 
5 X GN 1/1 

– 15 X GN 1/1 

Series: SKFME / SKFZK 

 
 
 

 

Summary of Contents for 15 X GN 1/1

Page 1: ...OPERATING MANUAL Blast chiller freezer 5 X GN 1 1 15 X GN 1 1 Series SKFME SKFZK ...

Page 2: ...ipment in the standby mode 9 7 2 Equipment in the cooling mode 9 7 3 Categories of food products 9 7 4 Automatic and individually set programs 9 7 5 Cycle in progress 10 7 6 Other functions 10 7 7 Machine in the heating mode 11 7 8 Combined mode option 11 7 9 Options 11 7 10 Alarms 12 7 11 Manual mode and Multilevel mode 12 7 12 USB 13 7 13 HACCP report 14 7 14 Help option 14 7 15 Modem option 14 ...

Page 3: ...mode One must keep in mind that the blast chiller freezer is intended for storage of products for up to 2 days 3 GENERAL TIPS The equipment is suitable only for quick cooling blast freezing of food products After the equipment is unpacked and the protections are removed please check if the equipment is not damaged If any damage is found please inform the supplier or installer immediately Before wo...

Page 4: ...s while performing regular maintenance work Do not put any devices or kitchen tools into the cover of electrical and mechanical parts Use appropriate and compatible equipment for maintenance When not in use the equipment should be switched off and the plug should be taken out of the power socket Failure to observe the above rules may affect the safety of the equipment and of the user The manufactu...

Page 5: ...an appropriate forklift in the vicinity of the eventual place of installation Cut the tape and pull the cardboard packaging upward In order to avoid damage to the equipment do not use knives or other similar tools Take out the wooden base and set the chiller in the final position Take off the PVC protective film from all sides Remove the plastic protection from the probe for measuring the temperat...

Page 6: ...6 Data plate on the back Control panel Door Legs with height adjustment Unit chamber with a grate air inlet cover Removable condensate container Door ...

Page 7: ...ercurrent switch or fuse The selected parameters and settings must correspond to those shown on the data plate The main switch must be located close to the equipment easily acceptable and enable its use each time for the equipment The ground cable made by the investor must be connected to the appropriate grounding terminals clamps of the equipment It is prohibited to use connections multiple plug ...

Page 8: ...ect the hot gas duct of the condenser to the hot gas duct of the blast chiller freezer Connect the suction duct of the condenser to the suction duct of the blast chiller freezer Open all closing valves in the system leave the common cooling cycle and check the tightness Fill the cooling equipment with the R404a R507 coolant If the condenser is set higher than the blast chiller freezer equip the sy...

Page 9: ...on The recommended minimum duration of the cooling is 15 minutes 7 3 Categories of food products Depending on the food product that is used at a given time the appropriate category of the product must be selected or the general manual mode must be performed Home Return to the main page and put the machine in the standby mode 7 4 Automatic and individually set programs In the left column there are ...

Page 10: ...process the machine emits an intermittent acoustic signal which can be switched off by clicking the flag symbol 7 6 Other functions Options go to the Options range Service go to the Service range Maintenance enables starting the maintenance cycle Thawing enables starting the thawing cycle Slow Cooking enables starting the cooking cycle in a low temperature option Proofing enables starting the proo...

Page 11: ...e to automatically and sequentially start the thawing proofing and slow cooking cycles as well as the quick cooling and freezing cycles In order to set a cycle click the relevant symbol and enter the appropriate values NOTE In the modes in which the food probe is used it is beneficial to maintain a temperature difference between air and the food product on the level of at least 10 C 7 9 Options US...

Page 12: ...e alarm line Visualization of useful information about deleting of an alarm NOTE Current alarms are deleted only when correct operation of the machine is restored 7 11 Manual mode and Multilevel mode Multilevel function NOTE The quick cooling manual freezing fermentation and maintenance mode do not involve use of a food probe Manual mode A simplified quick cooling of freezing mode During the manua...

Page 13: ...ur minute second e g 153000 temperature of the food probe C e g 3 5 7 9 air temperature C e g 5 alarms that occurred e g 0 power consumption W e g 1290 identification of the tip of the food probe with calculation e g 3 All the parameters are grouped and form a record A CSV file contains a list of records that are saved every 10 seconds in the format shown in the example below 010612 153000 3 5 7 9...

Page 14: ... the segment intended for the service technician there are video files that show ways to repair the machine e g ways to replace the fan or to access the electrical parts The segment intended for the user contains video files showing ways to use the machine e g how to switch on a cycle set a program or display an HACCP report 7 15 Modem option LED GSM The work mode of the modem is related to the av...

Page 15: ...ure probe evaporator 53 temperature probe condenser 54 temperature probe overheating 55 suction pressure 56 temperature probe power supply 4 57 temperature probe power supply 3 58 temperature probe power supply 2 59 temperature probe power supply 1 Working mode Function Quick cooling chilling freezing storage thawing cooking proving waiting Example S N 30136842024 51 10 52 25 53 50 54 0 55 0 56 9 ...

Page 16: ...8 2 CLEANING Before cleaning starts disconnect the equipment from the power supply mains Clean steel surface on the inside and on the outside of the equipment with a damp cloth and a neutral non abrasive cleaning agent Wipe the surfaces thoroughly with a piece of cloth do not rinse them with water and dry them thoroughly Do not scrub the surfaces with sharp objects Do not use any aggressive substa...

Page 17: ...ons set forth in the relevant regulations If you require service please contact the vendor from whom you purchased the equipment Please describe in detail the reason for the request and provide the data stated on the data plate on the back of the equipment See item 4 Technical data 10 SCRAPPING AND RECYCLING The structure of the blast chiller freezer comprises the following materials Stainless ste...

Page 18: ...18 11 CONNECTIONS LAYOUT ...

Page 19: ...19 ...

Page 20: ...20 ...

Page 21: ...21 ...

Page 22: ...stems for equipment with rated current 16 A per phase and not subject to conditional connection EN 60335 1 2012 03 Household and similar electrical appliances Safety General requirements EN 60335 2 34 2011 08 Household and similar electrical appliances Safety Particular requirements for motor compressors EN 378 1 2012 08 Refrigerating systems and heat pumps Safety and environmental requirements Ba...