Revision 6 – November, 2008
ADDP Manual
Page 5
3)
WELL LEVEL CONTROL VALVE
• The
well level control valve
is mounted on top of the
two stage filter/regulator
assembly. It uses a
well level sensor hose
down well to sense the fluid level
in the well. It supplies air to the
DDP
when the fluid level rises and shuts the
DDP
off when the fluid level recedes. (See Figure 1)
System with Foot Valve:
• The pneumatic sensor circuit has an
air bubbler
connected to the 1/4 inch
well level sensor hose
via a quick connect. (See Figure 2)
System with Top Loading Cup:
•
The pneumatic sensor circuit has an
air bubbler
located inside the
top
loading cup
. (See Figure 3)