Chapter 7: Troubleshooting
TROUBLESHOOTING
Problems can possibly occur and can easily be resolved by following the
instructions below. If you need assistance, please do not hesitate to call
QED
Environmental Systems (QED)
Service Department.
Excessive oil contamination from the air supply or exposure to freezing conditions
may cause damage that requires assistance from
QED
.
DDP
ceases to draw down the fluid level.
NO AIR TO THE SYSTEM
- Re-establish air to the system.
NO AIR TO THE DDP
- See if
air bubbler
is still bubbling. Blow into
well level
sensor hose
or fi ing to simulate high fluid level. (See Figure 2)
- Close and open
needle valve
to clear possible blockage.
- Adjust primary regulator so gauge reads between 40 and 100 psi.
- Change filter elements, if clogged.
AIR BUBBLER DOES NOT BUBBLE
- Close and open
needle valve
on far right of
pneumatic circuit to eliminate blockage. Adjust
needle valve
so
air bubbler
bubbles
about 5 bubbles per second. (See Figure 1)
EVERYTHING HAS PROPER AIR FLOW AND PRESSURE AND SYSTEM DOES
NOT FUNCTION
- Disconnect the
system air supply hose
from the
DDP
and
reconnect. An exhaust of air from the male fi ing should be heard when the
hose is disconnected. This is to "shock" the
DDP
drive past a position of high
friction. (See Figure 1)
Содержание ADDP
Страница 7: ...QED Environmental Systems Page 4 ADDP Manual Figure 1 ADDP System...
Страница 9: ...QED Environmental Systems Page 6 ADDP Manual Figure 2 ADDP System with Foot Valve...
Страница 10: ...Revision 6 November 2008 ADDP Manual Page 7 Figure 3 ADDP System with Top Loading Cup Chapter 1 Equipment...
Страница 14: ...Revision 6 November 2008 ADDP Manual Page 11 Figure 4 Locking Quick Connect Instructions Chapter 3 Assembly...