DANGER!
Risk of fatal injury due to electric shock!
When disconnecting an electric circuit carrying direct current,
electric arcs can occur that may result in life-threatening injuries.
Ä
Do NOT unplug the cable when under load.
Ä
Do NOT connect any exposed cable ends.
Ä
Do NOT touch the poles at the same time.
A solar module generates electrical current and voltage even at a
low intensity of illumination. Sparks and electric arcs may result
from the separation of a closed circuit. These can result in life-
threatening injuries. The danger increases when several modules
are connected in series.
Ä
Please ensure that the entire open circuit voltage is active even
at low levels of solar irradiation.
Ä
Please follow the valid national regulations and safety guidelines
for the installation of electrical devices and systems.
Ä
Please make sure to take all necessary safety precautions. With
module or phase voltages of more than 120 V, the extra-low
voltage range is exceeded.
Ä
Carry out work on the inverter and the wiring with extreme caution.
Ä
Ensure that the modules are disconnected at the inverter prior
to separation.
Ä
Be sure to observe the specified time intervals after switching off
the inverter. High-voltage components need time to discharge.
DANGER
! Risk of fatal injury due to electric shock!
Ä
Never open the junction box.
Ä
Do not remove bypass diodes.
DANGER
! Risk of fatal injury due to electric shock!
Ä
Never touch live contacts with bare hands.
Ä
Do not touch the poles at the same time.
DANGER
! Risk of fatal injury due to electric shock!
Ä
Insulate any exposed cable ends.
Ä
Only connect cables with plugs.
DANGER
! Risk of fatal injury due to electric shock!
Ä
Only use dry, insulated tools for electrical work.
4.1 Safety
4
eLeCTrICaL CoNNeCTIoN
DANGER
! Risk of fatal injury due to electric shock!
Ä
Ensure correct polarity.
DANGER
! Risk of fatal injury due to electric shock!
Ä
Be sure to maintain the time intervals as specified
by the inverter manufacturer between switching off
the inverter and beginning any further work.
DANGER
! Risk of fatal injury due to electric shock!
Ä
Never unplug the cable when under load.
1.
Switch off the inverter.
AUS
3.
Switch off the DC circuit breaker.
Ä
Disconnect plugs by the use of appropriate
and qualified tools of the manufacturer Tyco or
Multicontact (adequate for PV4 plug type).
2.
Cover the modules to be disconnected.
4.2 electrical installation safety
4
eLeCTrICaL CoNNeCTIoN