background image

 

 

 

 

 

 

 

 

 

 

 

Prism Pro/Multi-function Touch Panel 

User Manual 

(Applicable model: HDL-MPTFL11.46) 

 

 

 

 

 

 

 

Version: V1.0.0 

Published on Nov.22, 2019

Summary of Contents for HDL-MPLPI.46-A

Page 1: ...Prism Pro Multi function Touch Panel User Manual Applicable model HDL MPTFL11 46 Version V1 0 0 Published on Nov 22 2019 ...

Page 2: ...7 2 5 Indicator Intensity Setting 8 2 6 Other Settings Button Valid Status 9 2 7 Time and Date Setting 11 3 Button Setting 12 3 1 Button Objects Setting 12 3 1 1 Add Objects 13 3 1 2 Edit Objects 13 3 2 Button Status Setting 13 4 AC Setting 15 4 1 General Setting 15 4 2 Test 16 4 3 Other Function Setting 16 4 3 1 AC Setting 16 4 3 1 1 Temperature Model Setting 16 4 3 1 2 AC Temperature Range Setti...

Page 3: ...ouch Panel User Manual HDL Automation Co Ltd http www hdlchina com ii 5 Floor Heating Setting 21 6 Music Setting 24 7 LED Setting 26 7 1 LED Color Shortcuts Setting 26 7 2 LED White Balance Adjustment 27 8 Sleep Group Setting 28 ...

Page 4: ...rohibited without written authorization from HDL Any infringement of HDL s intellectual property rights will be investigated the legal liability The contents of this document will be updated as the updates of product versions or other reasons Unless otherwise agreed upon this document is to be used as a guidance only All the statements information and recommendations in this document makes no warr...

Page 5: ... Automation Co Ltd http www hdlchina com II Update History The form below contains the information of every update The latest version contains all the updates of all former versions No Version Update Information Date 1 V1 0 0 Initial release Nov 22 2019 ...

Page 6: ...onfiguration of Prism Pro in Buspro Setup Tool 2 The following tools might be included Prism Pro Multi function Touch Panel Model HDL MPTFL11 46 Panel Power Interface Model HDL MPLPI 46 A A computer with Buspro Setup Tool 2 1 Port Programming Gate Way connected to the router Dedicated Buspro Cable s Note Please refer to the datasheet attached to the product for the information of installation wiri...

Page 7: ...el button introduction Open Configuration Page Connect the panel to the system and open Buspro Setup Tool 2 in the computer Click Fast Search to search for the devices Double click the Model or Description column to enter panel configuration page as shown in Figure 1 2 Figure 1 2 Open panel configuration page ...

Page 8: ...ndby page the panel can be set to return to a specific page after a period of time with no operation Temperature feedback to enable broadcasting temperature Proximity sensor to enable human body detection Indicator intensity to set panel backlight and button indicator brightness Others includes the time setting of long press and double click the language selection and the minimum dimming value Tim...

Page 9: ...ttp www hdlchina com 4 2 1 Button Page Display Setting In Button page settings part as shown in Figure 2 2 user may select deselect corresponding button page to display hide Note user should at least display a button page instead of hiding all Figure 2 2 Button page setting ...

Page 10: ...ific page after a period of time with no operation 1 Don t return the panel stays in the current page after a period of time with no operation 2 Return to page delay s to set return page number and delay time after a period of time with no operation For example when return to page 2 delay 20s is set the panel will return to button page 2 after a period of time with no operation for 20s Figure 2 3 ...

Page 11: ... via built in temperature sensor temperature broadcasting can be enabled disabled in Temperature feedback setting part as shown in Figure 2 4 1 Broadcast to enable disable temperature broadcasting 2 Subnet Device ID to set device information for receiving temperature data 3 Type to select temperature unit including C and F Figure 2 4 Temperature feedback setting ...

Page 12: ...nsor enable to enable proximity sensor namely the panel will be woken up by detecting human body 2 Click sound to enable the click sound of corresponding button 3 Proximity sensor trigger key to select the button triggered after the panel detects human body which ranges from 1 to 36 4 Proximity sensor sensitivity higher sensitivity means longer distance for the panel to detect human body Figure 2 ...

Page 13: ... set value 4 Eco mode after a period of time with no operation panel backlight and button indicator brightness will be automatically the set value Delay 10s 99s to set the delay time between no operation and enabling eco mode Standby level to set panel backlight brightness in standby mode Trigger button when LCD wake up when the panel is in eco mode if the option is selected button will be trigger...

Page 14: ...ressed longer than the set time the object will be triggered 2 Double click time 0 1s 2s to set the time of double click which ranges from 0 1s to 2s The time interval between two clicks shorter than the set time will be identified as Double click to trigger objects 3 Choose language user may select Chinese English or customized language please refer to Customized Language Setting 4 Min dimming va...

Page 15: ...ton in Buspro Setup Tool 2 Select Image label Select object icon in Choose icon type This part takes Button page 2 icon as an example Select Customize in Choose language Double click Picture column corresponding to object icon Then select the customized icon and click open button Select Select All None and click Upload button When the process bar shows 100 user may check whether Light P2 Light 1 h...

Page 16: ...etting part as shown in Figure 2 9 user may select time type and date format Because time and date only appear in the standby page the panel can be set to return to page 10 after a period of time with no operation the standby page number is 10 in Return Standby Page Setting So that time and date will appear Figure 2 9 Time and date setting ...

Page 17: ...ct buttons to be set at the top Click Targets setting button on the right as shown in Figure 3 1 Note The number of objects depends on the button mode For example Combination ON Combination OFF Combination ON OFF Dbclick Combined Short Long Press Short Press Long Jog and Clock can control up to 99 objects while Single ON OFF Single ON and Single OFF only control 1 object Figure 3 1 Button objects ...

Page 18: ...the same way inputting from 2 to 4 represents adding 3 objects object 2 3 4 and inputting from 3 to 5 represents adding 3 objects object 3 4 5 5 Then 3 objects will appear in the object list below and click Save 3 1 2 Edit Objects Add objects in Add Objects and configure objects Continued from the preceding part Select objects in object list to change Subnet ID Device ID Type Mark of Figure 3 1 an...

Page 19: ...supports mutual exclusive function Double key to select whether continuous two buttons are combined as a button to use the objects of combined button are those of smaller button For example after combining button 1 with button 2 the objects of combined button are those of button 1 Figure 3 2 Button status setting ...

Page 20: ...AC will be OFF when the panel is powered on When Last status is selected AC will be in the status before the last power off when the panel is powered on HVAC No to enter corresponding AC number to control which ranges from 1 to 128 the default number is 1 Type Version 1 not support HVAC no and Version 2 support HVAC no Adjust to set temperature compensation for correcting temperature data detected...

Page 21: ... Figure 4 1 user may configure AC setting IR codes and Slave sync 4 3 1 AC Setting Click Setup button in AC setting page user may set temperature model temperature range and temperature sensor as shown in Figure 4 2 4 3 1 1 Temperature Model Setting Figure 4 2 shows the setting items below FAN to enable 4 fan modes Mode to enable 5 working modes Eco mode to enable disable eco mode If eco mode is e...

Page 22: ...p www hdlchina com 17 Figure 4 2 Temperature model setting 4 3 1 2 AC Temperature Range Setting As shown in Figure 4 3 the minimum maximum temperature in 4 work modes can be set in Temperature range page whose ranges are both from 0 to 30 Figure 4 3 Temperature range setting ...

Page 23: ...erature sensor If selecting Receive Feedback or Ask Feedback user may set the subnet ID device ID and channel of external sensor Average of internal and external the panel refers to the average of temperature from external and internal sensor Figure 4 4 Temperature sensor setting 4 3 2 IR Codes Setting IR control is that IR transmission module sends IR codes to indirectly control AC devices Click ...

Page 24: ...trol Invalid for Additional AC Page When several panels control the same AC user need to set synchronized panel information before synchronizing other panels Prism Pro can synchronize the AC information of up to 8 panels Click Slave Sync button in AC setting page and select Synchronous Control label as shown in Figure 4 6 Enable Disable Sync select to enable synchronizing other panels Synchronized...

Page 25: ...Prism Pro Multi function Touch Panel User Manual HDL Automation Co Ltd http www hdlchina com 20 Figure 4 6 Synchronous control setting ...

Page 26: ...floor heating Working mode includes Floor Heating Floor Cooling Auto and control mode includes Slave Control and Fully control Slave control to control up to 6 objects via switching objects Fully control fully control can set up to 4 floor heating channels and 4 floor cooling channels Temperature sensor when Fully control is selected the actual working modes should depend on the temperature Inner ...

Page 27: ...WM value range Heating speed to set the heating speed of floor heating Control cycle to set the control period of the relay and PWM whose ranges both are from 1 to 20 minutes Day Night start at timer mode includes Day Night mode floor heating automatically enters Day Night mode at the set time in Day Night start at Mode to enable 5 work modes Mode changeover auto mode between floor heating and flo...

Page 28: ... select to synchronize the floor heating ON OFF status of other panels 7 Sync temperature to synchronize the floor heating temperature of other panels Test to set floor heating ON OFF and mode Normal Day Night and Away For example select ON Heating to enable floor heating set mode to Heating and the temperature to 20 and save If configured successfully floor heating page should display Normal 20 ...

Page 29: ...iguration page as shown in Figure 6 1 Figure 6 1 Music setting The setting items are explained below Settings Enable Disable to enable disable music function Mode to select music device type including Z Audio NUVO and Casatunes Z Audio directly receives music control commands while other device types need to convert control commands by RS232 module ...

Page 30: ...he device ID of music device CMD list for playing music to double click object ID column to open configuration page An object can be respectively set by 0 6 music source switch for now user can set objects on the basis of requests Subnet ID the subnet ID of music source Device ID the device ID of music source Type to select Scene Universal switch or Single channel control Parameter the type and da...

Page 31: ... LED Color Shortcuts Setting Select LED color shortcuts label in the panel configuration page as shown in Figure 7 1 LED color to set button LED color in on off state Shortcut to set the page appearing after clicking clicking again the shortcut button which ranges from 1 to 9 Figure 7 1 LED Color Shortcuts Setting ...

Page 32: ... When button LED color differentiates from standard white user need to set button LED color to standard white in LED color shortcuts and correct white via changing the RGB value of LED white balance adjust which ranges from 0 to 100 For example when button LED color is set to white if the color shows a little red the R value need to be lowered until the color shows standard white Figure 7 2 LED wh...

Page 33: ...nd sleep brightness After the panel enables sleeping and the sleep group is selected sleep control command can be received This chapter takes When panel A enters sleep status panel B and C will enter at the same time as an example User may select Allow sleep and sleep group 1 in the sleep group setting of panel A B C Panel A B C will belong to sleep group 1 and click save When panel A enters sleep...