persists, contact your dealer or service
organization.
LOW FLOW
Persistent low flow problems. (Occurs
on the third occurrence of the “HTR
FLOW LOW” message.) Heater is shut
down, but other spa functions continue
to run normally.
Follow action required for “HTR FLOW
LOW” message.
Turn spa off then back on again to restore
heating capability.
HEATER MAY
BE DRY –
WILL RESET
SHORTLY
Inadequate water detected in heater.
Check water level in spa. Refill if necessary.
If the water level is okay, make sure the
pumps have been primed. Press any button to
reset.
HEATER DRY
SERVICE RQD
Inadequate water detected in heater.
Displays on third occurrence of
“HEATER MAY BE DRY - WILL
RETEST SHORTLY” message.) Spa is
shut down.
Follow action required for “HEATER MAY
BE DRY - WILL RETEST SHORTLY”
message. Spa will not automatically reset;
you may press any button to reset.
PRIMING MODE
TAKES 4 MIN
When your spa is first actuated, it will
go into Priming mode.
The Priming mode will last for up to 4
minutes and then the spa will begin to heat
the spa and maintain the water temperature in
the Standard mode.
--F
°
or --C
°
Temperature Unknown.
After the pump has been running for 2
minutes, the temperature will be displayed.
----
Temperature not current in Economy or
Sleep Mode.
In Economy or Sleep mode, the pump may
be off for hours outside a filter.
If you wish to see the current spa
temperature, either switch to Standard mode
or turn Jets1 on for at least two minutes.
STANDARD
MODE
Standby Mode has been activated by
pressing a button combination on user
panel.
Press any button to leave Standby Mode and
return operation.
Periodic Reminder Messages
(“Press the Mode” button to reset a displayed message)
Message Frequency
Action
Required
CLEAN FILTER
Every 30 days
Remove, clean, and reinstall filter per
manufacturer’s instructions.
TEST GFCI
Every 30 days
Test & reset GFCI per manufacturer’s
instructions.
DRAIN WATER
Every 90 days
Drain and refill spa per manufacturer’s
instructions.
CLEAN COVER
Every 180 days
Clean and condition cover per
manufacturer’s instructions.
TREAT WOOD
Every 180 days
Clean and condition cover per
manufacturer’s instructions.
NEW FILTER
Every 364 days
Install new filter.
8