background image

persists, contact your dealer or service 
organization. 

LOW FLOW 

Persistent low flow problems. (Occurs 
on the third occurrence of the “HTR 
FLOW LOW” message.) Heater is shut 
down, but other spa functions continue 
to run normally. 

Follow action required for “HTR FLOW 
LOW” message.  

Turn spa off then back on again to restore 
heating capability. 

HEATER MAY 
BE DRY –   
WILL RESET 
SHORTLY 

Inadequate water detected in heater. 

Check water level in spa. Refill if necessary. 
If the water level is okay, make sure the 
pumps have been primed. Press any button to 
reset. 

HEATER DRY 
SERVICE RQD 

Inadequate water detected in heater. 
Displays on third occurrence of 
“HEATER MAY BE DRY - WILL 
RETEST SHORTLY” message.) Spa is 
shut down.

 

Follow action required for “HEATER MAY 
BE DRY - WILL RETEST SHORTLY” 
message. Spa will not automatically reset; 
you may press any button to reset. 

PRIMING MODE 
TAKES 4 MIN 

When your spa is first actuated, it will 
go into Priming mode. 

The Priming mode will last for up to 4 
minutes and then the spa will begin to heat 
the spa and maintain the water temperature in 
the Standard mode. 

--F

°

 or --C

°

 

Temperature Unknown.  

After the pump has been running for 2 
minutes, the temperature will be displayed. 

---- 

Temperature not current in Economy or 
Sleep Mode. 

In Economy or Sleep mode, the pump may 
be off for hours outside a filter.  

If you wish to see the current spa 
temperature, either switch to Standard mode 
or turn Jets1 on for at least two minutes. 

STANDARD 
MODE 

Standby Mode has been activated by 
pressing a button combination on user 
panel. 

Press any button to leave Standby Mode and 
return operation. 
 

 

 

Periodic Reminder Messages

 (“Press the Mode” button to reset a displayed message) 

Message Frequency 

Action 

Required 

CLEAN FILTER 

Every 30 days 

Remove, clean, and reinstall filter per 
manufacturer’s instructions. 

TEST GFCI 

Every 30 days 

Test & reset GFCI per manufacturer’s 
instructions. 

DRAIN WATER 

Every 90 days 

Drain and refill spa per manufacturer’s 
instructions. 

CLEAN COVER 

Every 180 days 

Clean and condition cover per 
manufacturer’s instructions. 

TREAT WOOD 

Every 180 days 

Clean and condition cover per 
manufacturer’s instructions. 

NEW FILTER 

Every 364 days 

Install new filter. 

 

8

Содержание Paradise Series

Страница 1: ...e sincerely hope you enjoy aradiseSeries ML 900 2 07 Your QCA Paradise Majestic Series Spa ML 900 Panel OWNER S MANUAL T spa We think it is important for you to take a few moments and get acquainted w...

Страница 2: ...4 115 240v Installations 4 Jets Jets Jets 11 Prevention of Freezing 13 14 QCA Spa Light 11 Refilling your Spa 12 Removing the Filter Cartridge 13 Sequencer Controller 8 Spa and Cabinet Maintenance 14...

Страница 3: ...isk of injury a The water in a spa or hot tub should never exceed 40 C 104 F Water temperatures between 38 C 100 F and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are r...

Страница 4: ...to provide drainage of the compartment for the electrical components 7 Install your spa in a location which allows easy access to the equipment bay 8 Before filling with water be sure the spa is in it...

Страница 5: ...ncrease or decrease depending on which button is pressed After three seconds the LCD will automatically display the last measured spa temperature Note that the last measured spa temperature displayed...

Страница 6: ...r modes press the Light button off and on to cycle the unit If the light or LED unit is left on it will automatically turn off after 4 hours OPTIC Button is not used for this model Preset Filter Cycle...

Страница 7: ...Overheat The spa has shut down On some systems an alarm may sound One of the sensors has detected 118 F approximately 47 8 C at the heater DO NOT ENTER THE WATER Remove the spa cover and allow water t...

Страница 8: ...then the spa will begin to heat the spa and maintain the water temperature in the Standard mode F or C Temperature Unknown After the pump has been running for 2 minutes the temperature will be display...

Страница 9: ...uence is where all valves are opened at the same time and does not have an indicator light A preview of the massage is displayed for 5 seconds after selecting a sequence To change sequence speed Press...

Страница 10: ...the Turbo Boost valve Hydro Max Seat 2 Seats 1 3 Turn on Jets 1 Rotate the diverter valve that separates the Hydro Max seat and the Volcano Jet until the volcano jet is off This will allow seat 1 2 an...

Страница 11: ...ed on the side of the Equipment Module This receptacle is provided for the connection of the spa light Your QCA Majestic Spa has a standard 12v light The Spa light may be turned ON or OFF by pressing...

Страница 12: ...lower than 7 2 add pH UP B If pH is higher than 7 8 add pH DOWN C If total alkalinity is below 80 add ALKALINITY UP Step 3 Shock treats the water with non chlorine shock to destroy any organic contam...

Страница 13: ...hard solid material it may indicate a calcium build up on the fabric This build up can be removed by soaking the cartridge in proper cartridge cleaning solution available through your QCA dealer When...

Страница 14: ...if you wish to retain your cabinet s original deep rich look and protect it from warpage we recommended applying a good quality wood protector and moisture sealant The spa s environment such as the a...

Страница 15: ...gift to help maintain your spa and to VALIDATE your spa warranty return the PREPAID registration card below within the next thirty days To immediately register your new spa you may log onto our web si...

Отзывы: