background image

NOTE: Not maintaining your water can result in 

damage of your spa jets, filter, etc. This 
damage, due to incorrect water maintenance, is 
not covered under warranty. 

 

Filter Maintenance 

 

As with any water filtering system, the filter 
cartridges may become clogged with particles or 
with calcification that will result in reduced water 
flow. In your QCA Spa, it is important to maintain 
a clean, unobstructed filtering system. This not 
only provides the maximum performance from the 
hydrotherapy jets, but allows the 24 hour filtration 
system to function effectively. We recommend the 
filter cartridges be cleaned (either spraying clean 
with water or soaking to dissolve minerals) 
EVERY MONTH.

 

 
WARNING:

 Failure to maintain the cartridges in 

a clean, unobstructed manner will result in reduced 
water flow through the heater assembly which may 
cause the Heater High Limit Thermostat to "trip". 
If this high limit "trip" occurs during sub-freezing 
temperatures and goes unnoticed, the spa water 
may freeze. Any damage to the spa (from 
freezing), which is a direct cause of poor 
maintenance, will not be covered by warranty. 

 

 

 

Removing the Filter Cartridge

 

 

The cartridge of the in-line filter must be removed 
for cleaning. This is accomplished as follows: 

 

1.

 

Remove filter lid.  

2.

 

Twist and lift built-in chemical dispenser and 
remove the cartridge.  

3.  Remove the filter cartridge from the housing 

and clean, or replace it with a new cartridge. 

 
Cleaning the Filter Cartridge 

 
1.  Hold the cartridge in an upright position and 

spray downward into the pleats of the fabric 
with a garden hose to flush away debris. 
Cleaning will be easier if the garden hose 
nozzle can be adjusted to a single jet spray. 

2. After hosing off the cartridge, it is highly 

recommended that the cartridge be allowed to 
soak in a filter-cleaning solution available 
through your local dealer. Soak the cartridge 
for 24 hours to remove body oils and body 
lotions that become impregnated in the 
cartridge fabric during filtration. Rinse the 
cartridge thoroughly before placing it back in 
the filter housing.

 

 

NOTE: If two filter cartridges are available, it is 
recommended to allow filter cartridge to dry 
before new usage. 

 

3. If the cartridge is coated with hard, solid 

material, it may indicate a calcium build-up on 
the fabric. This build-up can be removed by 
soaking the cartridge in proper cartridge 
cleaning solution available through your QCA 

dealer. When using this solution, follow 
instructions provided on label. 

4.  If the cartridge is coated with algae or bacteria, 

it should be soaked in a solution of one part 
chlorine and four parts water in a plastic 
container. As a safety precaution, rubber gloves 
should be worn while handling this solution. 
Brushing the solution into the fabric pleats may 
also help remove algae or bacteria. Rinse the 
cartridge thoroughly before placing it back into 
the filter housing. 

 

Observe manufacturers recommended safety 
procedures when using acid or chlorine. Always 
rinse the cartridge thoroughly after applying these 
solutions. 

 
5.  Clean the filter housing and filter housing O-

ring. Lubricate the O-ring with silicone 
lubricant. 

6.  Return the filter cartridge to the housing and 

replace the housing lid. 

 

Vacation Care Instructions

 

If you plan to be away, follow these instructions to 
maintain the water quality:

 

 

Short Time Periods (3-5 Days): 

 

1.

 

Adjust the pH by following the instructions 
outlined in the water quality and maintenance 
section.  

2.

 

Sanitize the water by following the "super-
chlorination" procedures and lock your thermal 
cover in place using the tie-downs. 

3. 

Upon your return, sanitize the water 
(superchlorinate, if necessary) and balance the 
pH. 

 
IMPORTANT NOTE:

 Spa water oxidizers such as 

dichlor chlorine maintain their level of 
effectiveness substantially longer in cool water 
than in hot water. 

 

Long Time Periods (4-15 Days): 

Prior to leaving: 
1.  Adjust the pH as required. 
2.  Sanitize the water by following the SUPER-

CHLORINATION procedures. 

3.  Upon your return, check the level of sanitation 

of your spa water. If the chlorine test reads "O" 
and you have been gone an extended period of 
time, SUPER-CHLORINATE the spa water to 
ensure all organisms or algae are oxidized. 
Turn the Temperature Control clockwise to 
return it to the original setting. The spa water 
will be safe for you to use once the Free 
Chlorine Residual has dropped below 5.0 ppm. 

 
 

Prevention of Freezing 

The QCA Spa has been designed and engineered 
for year-round use in any climate.  The energy 
efficiency of the spa may decrease during these 
cold periods, as the heater will cycle more 
frequently. If a freeze condition is detected, the 

 11

Содержание Jewel +3 Series

Страница 1: ...n spa We think it is important for you to take a few moments and get acquainted with your new spa operation Please keep this manual available for references QCA Spas would like to congratulate you on...

Страница 2: ...240v Installations 4 Jets Jets Jets 9 Prevention of Freezing 11 12 QCA Majestic Spa Light 9 Refilling your Spa 10 Removing the Filter Cartridge 11 Sequencer Controller 8 Spa and Cabinet Maintenance 1...

Страница 3: ...isk of injury a The water in a spa or hot tub should never exceed 40 C 104 F Water temperatures between 38 C 100 F and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are r...

Страница 4: ...to provide drainage of the compartment for the electrical components 7 Install your spa in a location which allows easy access to the equipment bay 8 Before filling with water be sure the spa is in it...

Страница 5: ...tton is pressed After three seconds the LCD will automatically display the last measured spa temperature Note that the last measured spa temperature displayed is current only when the pump has been ru...

Страница 6: ...con will light when filter 2 is running Optional Filter Cycle Programming You are not required to set filter cycles however it is an option available to you To change the filter cycle settings Press T...

Страница 7: ...ct your dealer or service organization May appear temporarily in an overheat situation and disappear when the heater cools SnB Spa is shut down The sensor that is plugged into the Sensor B jack is not...

Страница 8: ...been activated by pressing a button combination on user panel Press any button to leave Standby Mode and return operation Periodic Reminder Messages Press the Mode button to reset a displayed message...

Страница 9: ...cle located on the side of the Equipment Module This receptacle is provided for the connection of the spa light Your QCA Majestic Spa has a standard 12v light The Spa light may be turned ON or OFF by...

Страница 10: ...lower than 7 2 add pH UP B If pH is higher than 7 8 add pH DOWN C If total alkalinity is below 80 add ALKALINITY UP Step 3 Shock treats the water with non chlorine shock to destroy any organic contami...

Страница 11: ...hard solid material it may indicate a calcium build up on the fabric This build up can be removed by soaking the cartridge in proper cartridge cleaning solution available through your QCA dealer When...

Страница 12: ...d protector and moisture sealant The spa s environment such as the amount of light or humidity will determine how often repeat applications are required Consult your local hardware store for wood fini...

Страница 13: ...gift to help maintain your spa and to VALIDATE your spa warranty return the PREPAID registration card below within the next thirty days To immediately register your new spa you may log onto our web si...

Отзывы: