SPAVAC™ Kit

 – Optional 

Your QCA SPAVAC™ can be used with garden 
hose pressure or provided vacuum hose.  Your 
QCA Majestic Spa is equipped with a wall 
skimmer.  For use with garden hose, the 
SPAVAC™ is equipped with a fine mesh screen 
bag which can be easily cleaned after use.  For use 
with the vacuum hose, remove bag from the 
suction chamber, vac hose adaptor is then snapped 
into place.  All debris will be removed through 
filter system. 
 

Spa Care and Maintenance 

It is recommended to completely drain the spa at 
least four times a year. Otherwise, the water 
becomes chemically "saturated" and no longer 
responds to regular chemical upkeep. The spa 
should also be drained before long periods of 
disuse, or for equipment repair. 
 

Draining of Water

 

Because of the small water volumes involved with 
spas, sometimes it is much simpler and less 
expensive to drain the water than to adjust the 
water chemistry with chemical additives. To drain 
the spa, shut off the main breaker to your spa 
equipment pack.  Use a wet/ dry vac to remove the 
remaining amount of water. 

 

Options for Draining the Water 

 
1.

 

Simply siphon water from spa with garden 
hose. 

2.

 

A sump pump may be used to pump water from 
spa. 

 

Refilling your Spa 

 
1. Shut off the main breaker to your spa 

equipment pack.  

2.  Fill spa with water. 
3.  Turn Power back on, spa will automatically 

start to run and heat water to set temperature. 

 

Your Water Care Program 

Before adding chemicals to your spa, do a full 
water analysis with a test kit or ask your QCA Spa 
dealer to conduct the water test for you. 

 

Step 1: Always have the circulation system 
running before adding any chemicals. As you fill 
your spa to the level recommended by the 
manufacturer, add cleaning agent to prevent metal 
staining and to protect equipment against scale and 
corrosion. Circulate for one hour. 

 

Step 2: "Balance" the water so that it is neither 
alkaline (scale forming) nor acidic (corrosive). 
Balanced spa water should be 7.2 - 7.8 on the pH 
scale, with total alkalinity (the measure of the 
ability of water to resist a change in pH) in the 
range of 80-120 parts per million (ppm). 

 

A.  If pH is lower than 7.2, add pH UP 

 

B.  If pH is higher than 7.8, add pH DOWN 

 

C. 

If total alkalinity is below 80, add 
ALKALINITY UP. 

 
Step 3: Shock treats the water with non chlorine 
shock to destroy any organic contaminants that 
may have accumulated in the spa during filling. 

 

Step 4: Add Clarifier to keep water sparkling clear. 
Circulate one hour. 

 

Step 5: Prepare your disinfectant dispenser or 
feeder for use according to directions. A bromine 
residual of 2.0 - 4.0 ppm, as determined by your 
test kit, should be maintained at all times. 
Directions for using the bromine are indicated on 

e float ring. 

th

       

 

 

We suggest you follow a regular maintenance 
program to keep your spa water fresh and crystal 
clear

.  

 

Daily Checklist 

 
1.  Test for proper bromine level. Replenish spa 

floater dispenser or feeder with bromine tabs as 
needed. Proper bromine level should be 
maintained at 2.0 - 4.0 ppm. 

2.  Test pH levels and adjust if needed. If you are 

having difficulty-keeping pH properly 
balanced, it may be an indication that total 
alkalinity needs adjusting. Have your dealer 
test the water and adjust if needed.  

 

Weekly Checklist 

 
1.  Add Clarifier to help the filter remove small 

particles and to retain water clarity. 

2. Add Chelating Agent to protect your 

equipment against stains, scale and rust.  

3.  For spas located outdoors or subject to a great 

deal of sunlight add Algaecide to guard against 
algae. 

4. Shock your spa weekly with Oxidizer to 

remove contaminants such as ammonia, body 
oils and foreign matter. Unless spa water is 
routinely shock treated, contaminants will 
accumulate to cause eye and skin irritation, 
odors and cloudy dull water appearance. 

5.  To eliminate and prevent foaming, add a small 

amount of NON FOAM as needed.  

 

General Guidelines 

 

• 

NEVER MIX CHEMICALS    
TOGETHER

 

•  Add only small amounts of each chemical at a 

time until the desired value is achieved. Do not 
exceed dosage rates on label directions.  

•  Keep spa free of debris and cover spa when not 

in use. 

•  Circulate the water for 2-4 hours each day to 

maintain proper filtration. Clean your filter 
with FILTER CLEANER every 1-2 months.  

•  Remove oils and grease around water line with 

a cleaner on a weekly basis. 

•  In heavily used spas, water should be drained 

and refilled every two months or whenever it 
becomes difficult to maintain proper chemical 
levels.  

 

 10

Содержание Jewel +3 Series

Страница 1: ...n spa We think it is important for you to take a few moments and get acquainted with your new spa operation Please keep this manual available for references QCA Spas would like to congratulate you on...

Страница 2: ...240v Installations 4 Jets Jets Jets 9 Prevention of Freezing 11 12 QCA Majestic Spa Light 9 Refilling your Spa 10 Removing the Filter Cartridge 11 Sequencer Controller 8 Spa and Cabinet Maintenance 1...

Страница 3: ...isk of injury a The water in a spa or hot tub should never exceed 40 C 104 F Water temperatures between 38 C 100 F and 40 C 104 F are considered safe for a healthy adult Lower water temperatures are r...

Страница 4: ...to provide drainage of the compartment for the electrical components 7 Install your spa in a location which allows easy access to the equipment bay 8 Before filling with water be sure the spa is in it...

Страница 5: ...tton is pressed After three seconds the LCD will automatically display the last measured spa temperature Note that the last measured spa temperature displayed is current only when the pump has been ru...

Страница 6: ...con will light when filter 2 is running Optional Filter Cycle Programming You are not required to set filter cycles however it is an option available to you To change the filter cycle settings Press T...

Страница 7: ...ct your dealer or service organization May appear temporarily in an overheat situation and disappear when the heater cools SnB Spa is shut down The sensor that is plugged into the Sensor B jack is not...

Страница 8: ...been activated by pressing a button combination on user panel Press any button to leave Standby Mode and return operation Periodic Reminder Messages Press the Mode button to reset a displayed message...

Страница 9: ...cle located on the side of the Equipment Module This receptacle is provided for the connection of the spa light Your QCA Majestic Spa has a standard 12v light The Spa light may be turned ON or OFF by...

Страница 10: ...lower than 7 2 add pH UP B If pH is higher than 7 8 add pH DOWN C If total alkalinity is below 80 add ALKALINITY UP Step 3 Shock treats the water with non chlorine shock to destroy any organic contami...

Страница 11: ...hard solid material it may indicate a calcium build up on the fabric This build up can be removed by soaking the cartridge in proper cartridge cleaning solution available through your QCA dealer When...

Страница 12: ...d protector and moisture sealant The spa s environment such as the amount of light or humidity will determine how often repeat applications are required Consult your local hardware store for wood fini...

Страница 13: ...gift to help maintain your spa and to VALIDATE your spa warranty return the PREPAID registration card below within the next thirty days To immediately register your new spa you may log onto our web si...

Отзывы: