Optimizer4D Technical Specifications

14 / 27

QASS µmagnetic power amplifyer

Power amplifyer for hardness testing

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A

A

B

B

C

C

D

D

E

E

F

F

A2

Aufbau und Komponenten 

µM

Status

Änderungen

Datum

Name

Gezeichn.
Kontroll.
Norm

Datum

Name

03.08.2017 Nilges

Angaben in Millimeter

 

Schutzvermerk ISO 16016 beachten

Toleranz: ISO 2768 -  

Oberfläche:

ISO 1302

Härte:

 

µM Komponenten und Verkabelung.idw

1 : 2

Maßstab:

Rev.: 

19

0,

5

233,1

90

,3

86

,6

Füße demontierbar

µM-PA

93,50

16

,0

0

63,70

R2

0,0

0

20

,8

M5

x0

.8

M5x0.8

20

,0

0

1/4-2

0 UNC

30,00

1/4-20 UNC

1/4-20 UNC

15,00

UMS 5-5-15

103,70

74,20

50,00

21

,0

0

30

,0

0

O-PA

4x M

3

6,

77

Dimensions are shown in millimeters. 

This power amplifyer is installed bet-
ween measuring computer and sensor. 
The connection cable has a length of up 
to five meters. 

Power amplifyer cable
Connection is established with a scree-
ned 8-pin cable. This enables DC power 
supply as well as AC power supply of 
QASS µmagnetic sensors. 
Connection to power amplifyer is 
established with a Lumberg SV80 plug, 
connected to the Lumberg KFV80 socket 
of the power amplifyer. 

Attention!

Line voltage MUST be adjusted to local 
voltage with this  switch. In Europe: 230 
Volt, in North America: 115 Volt. 

Do not attach this pre amplifyer to move-
able machine parts! 

Switch for local voltage

Pin assignment of KFV80 connection

1

-

2

-

3

-

4

+ AC

5

- AC

6

GND

7

VCC

8

-

Содержание Optimizer4D

Страница 1: ...020 20 info qass net www qass net Ust IdNr DE215478481 Volksbank Bochum Witten eG BLZ 430 601 29 Kto 861 482 400 Commercial Register Hagen HRB 5423 CEO Ulrich Seuthe BIC GENODEM1BOC IBAN DE21430601290...

Страница 2: ...ation 8 QASS Optimizer4D magnetic pre amplifier 9 QASS Optimizer4D sensors adapter 11 QASS magnetic sensor 13 QASS magnetic power amplifier 14 QASS magnetic electrical characteristics 15 QASS magnetic...

Страница 3: ...ntegrated into a control cabinet It s also possible to use the unit with a separate case for example if the device is used with a manual mode machine It s possible to connect Optimizer4D to a notebook...

Страница 4: ...sing Protection class IEC 417 1 Isolation voltage 1000 V DC Excess voltage class II Contamination class II EMC Standards CISPR 22 EN 55022 IEC 1000 4 2 3 4 5 IEC 1000 3 2 3 certification Machine side...

Страница 5: ...7 do not use the lower port that comes with specific versions b the USB 2 0 connector 8 marked with black color inside of the socket do not use the blue sockets c the power supply 9 Connectivity opti...

Страница 6: ...t 1 GND Input 2 Power Switch ON2 Works as Power on switch when combined with ON1 Input 2 2 1 Select work piece Strobe Input 2 2 2 Select work piece 0 Input 2 2 3 Select work piece 1 Input 2 2 4 Select...

Страница 7: ...Remove the cover of the PLC connectors at the back of the device by loosening 2 screws 1 2 Unscrew the screws that hold the harddrives in place 2 3 Remove and exchange harddrives 3 Attention Mind the...

Страница 8: ...r port allocation Uninterrupted power supply UPS Integrated uninterrupted power supply UPS This component consists of several supercapacitors Super Caps In case of a blackout the UPS enables the measu...

Страница 9: ...Optimizer4D pre amplifier with six inputs Dimensions are shown in millimeters Cable allocation of ethernet cable from preamplifier to measuring computer 1 Analogue signal differential signal pair 2 3...

Страница 10: ...g on the kind of usage you can choose between several lines different lenghts different line sheathings e g teflon or synthetic material Acoustic emission sensors 1 A 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 B C...

Страница 11: ...Optimizer4D Technical Specifications 11 27 Magnetic adapter for sensor Dimensions are shown in millimeters Magnetic Adapter...

Страница 12: ...mmissio ning Optimizer4D executes a self test in order to determine if the sensors are correctly installed among other things Sensor cable with MCX connectors Sensor M5 previous version with creamic a...

Страница 13: ...for the excitation field that can be done in the signal gene rator of Optimizer4D Step Value Amplitude 4 0 25 V Frequency 1000 100 Hz The cable that connects the sensor and the pre amplifyer comes wit...

Страница 14: ...p to five meters Power amplifyer cable Connection is established with a scree ned 8 pin cable This enables DC power supply as well as AC power supply of QASS magnetic sensors Connection to power ampli...

Страница 15: ...field Max 1 2 T Sensor temperature range 20 C to 70 C 4 Fahrenheit to 158 Environmental temperature 0 50 Celsius 32 Fahrenheit to 122 QASS magnetic power amplifyer General characteristics Device QASS...

Страница 16: ...lung idw 1 5 Ma stab Rev L ngen 1 0 2 5 5 0 m O CC WTA L ngen 1 0 2 5 5 0 m O CC WTA L ngen 1 0 2 5 5 0 m O CC VVK L ngen 3 0 5 0 10 m O CC WTA O CC VVK A 1 1 B 1 1 C 1 1 D A B E 4 4 5 5 6 6 7 7 8 8 A...

Страница 17: ...0 00 110 00 41 00 M3 X Z Z A B C D E F Y 320 00 31 50 Y 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C D D E E F F 2 A2 TechData Bildschirm Status nderungen Datum Name Gezeichn Kontroll Norm Datum Name 1...

Страница 18: ...2 2 3 3 4 4 5 5 6 6 7 7 A B C D E F 3 A2 TechData Bildschirm Status nderungen Datum Name Gezeichn Kontroll Norm Datum Name 13 12 2016 Nilges Ma stab 1 2 Angaben in Millimeter Schutzvermerk ISO 16016...

Страница 19: ...e Rev Oberfl che 224 00 3 30 4 4 143 41 100 00 5 50 14 4 258 38 17 4 1 1 2 2 3 3 4 4 5 5 6 6 7 7 A B C D E F 1 A2 Neue Wandhalterung Waagerecht mit Zwischenblech nderungen Datum Name Gezeichn Kontroll...

Страница 20: ...che 129 00 272 8 90 00 120 69 2 M3x0 5 5 50 10 00 11 1 1 2 2 3 3 4 4 5 5 6 6 A B C D E F 1 A2 Neue Wandhalterung Senkrecht mit Zwischenblech nderungen Datum Name Gezeichn Kontroll Norm Datum Name 07...

Страница 21: ...Ma stab 1 1 Generisch Angaben in Millimeter Schutzvermerk ISO 16016 beachten Toleranz ISO 2768 H rte Rev Oberfl che 224 00 3 30 4 4 143 41 100 00 5 50 14 4 258 38 17 4 Vertical installation 1 1 2 2 3...

Страница 22: ...6 7 7 A B C D E F 1 A2 Schaltschrankeinbau_1 Status nderungen Datum Name Gezeichn Kontroll Norm Datum Name 13 12 2016 Nilges Ma stab 1 2 Angaben in Millimeter Schutzvermerk ISO 16016 beachten Toleranz...

Страница 23: ...optional signal lamp shows if a work piece is good or faulty by a red or a green light Open protective casing QASS Optimizer4D inside of a protective casing signal lamp optional added Measurements wei...

Страница 24: ...s QASE is made of durable plastics Optimi zer4D is securely installed into this casing and by this it s applicable for mobile and scientific uses QASE includes protective foam case inserts and compart...

Страница 25: ...te Optimizer4D saves up to 25 MB s to harddrive This means 1 5 GB min or 90 GB h 1 TB of memory will be full in roughly 11 hours Additionally Optimizer4D saves results of measuring crack no crack as s...

Страница 26: ...t case for horizontal mounting O MC Case 11 HW 1 5 3 Wall bracket Optimizer4D for horizontal mounting O MC Case11 WHW 4 Wall bracket case for vertical mounting O MC Case11 HS 5 Wall bracket Optimizer4...

Страница 27: ...os Name Type Order Nr Weight kg 8 Power supply 24 V 150 W O POWERSUPPLY 0 58 9 Uninterrupted power supply UPS Internal Supercaps O USV 0 36 10 Screen 11 6 Inches O TD 12 1 5 Please find the detailed M...

Отзывы: