INSTALLATION INSTRUCTIONS 

 

 

 
 
For HNE Rangehoods 

 

 

For HNR Rangehoods 

 

 

  

 

 

 

 

1.  Loosen screws ‘A’ and ‘B’ by turning anti clockwise. 

2.  Turn screw ‘D’ anti-clockwise to extend the outer spring bracket. 

3.  Insert the rangehood into the cut out. Ensure spring brackets are positioned on top of 

cupboard base. Turn screw ‘C’ clockwise to align rangehood with cupboard base.  

4.  Do not over tighten. 

5.  Tighten screw ‘A’ by turning clockwise to lock fixing bracket. 

6.  Fit off ductwork as required. 

7.  To remove rangehood, turn screw ‘D’ clockwise. 

 

An accessible 10A GPO is to be provided near the top RHS of the Rangehood for 

connection.  

 

 

 

Содержание Harvey Norman HNE Series

Страница 1: ...Harvey Norman HNE HNR Undercupboard Rangehoods Installation Instructions User Guide...

Страница 2: ......

Страница 3: ...1 The installation of Harvey Norman Rangehoods must comply with the information in this booklet 2 Every Harvey Norman Rangehood must be ducted to the outside atmosphere by the use of metal rigid duct...

Страница 4: ...wledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety e Children should be supervised to ensure that they do not play w...

Страница 5: ...mm 250 x 585mm HNR 90L 1 T 240 x 880mm 280 x 900mm 295 x 910mm 250 x 885mm HNR 90L 2 T 240 x 880mm 280 x 900mm 295 x 910mm 250 x 885mm HNE 60L 1 T 340 x 570mm 380 x 600mm 395 x 610mm 350 x 575mm HNE 9...

Страница 6: ...gehood into the cut out Ensure spring brackets are positioned on top of cupboard base Turn screw C clockwise to align rangehood with cupboard base 4 Do not over tighten 5 Tighten screw A by turning cl...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ...exposed in Alfresco areas we recommend spraying the hood with vegetable oil and rubbing it all over the rangehood if it is going to be unused over a period of time FILTER CLEANING For the best results...

Страница 11: ...QASAIR Ducting...

Страница 12: ...l Vent 200 123 CH 200 Chairman s Hat 200 124 CH 200 CB Chairman s Hat 200 Colourbond 127 BD SQ RC 200 Back Draft Roof Cowl Single Motor 200 142 FRC 200 SS Fire Rated 200 Roof Cowl 445M2 Stainless Stee...

Страница 13: ...232 CH 300 Chairman s Hat 300 233 CH 300 CB Chairman s Hat 300 Colourbond 234 BD SQ RC 300 Back Draft Roof Cowl 300 256 BD WV 300 Back Draft Wall Vent 300 263 FRC 300 SS Fire Rated 300 Roof Cowl 445M2...

Страница 14: ...ested To clean filter regularly by handwashing or placing in a dishwasher at least once a month To turn rangehood off after each use Note Warranty under the cleaning page Where a claim is made under w...

Страница 15: ...urner or a total mega joule rating In practice any barbecue or outdoor cooking appliance over 50 mega joules will need a specially made rangehood with an air movement exceeding 2000 cubic meters per h...