It is important to follow the installation instructions. 

 

 

By following these instructions for the installation, use and care of your Harvey Norman 

under cupboard rangehood will ensure many years of safe and reliable operation. 

 

Gas regulations require different heights for different brands of rangehoods. HNE & HNR 

Harvey Norman Rangehoods can be fitted 600 mm above the top of the highest burner of a 

gas hotplate. We recommend 700 to 800mm above the hotplate for optimum performance, 

and a minimum height of 750mm above Induction Hotplates. 

 

The Harvey Norman HNE & HNR rangehoods are all meant to be put into cupboards over 

hotplates and can vary in height due to the kitchen design. The rangehood can be installed 

flush or proud mount. For flush mount the cupboard base panel should be recessed 12mm. 

In either case the minimum clearance of the rangehood shall be no less than 600mm above 

the top of the highest gas burner or electric hotplate. 

 

1.  The installation of Harvey Norman Rangehoods must comply with the information in this 

booklet.  

 

2.  Every Harvey Norman Rangehood must be ducted to the outside atmosphere by the use 

of metal rigid ducting. 

Do not use of any type of plastic PVC piping

. Rangehoods 

must not be vented into a wall cavity or a ceiling space. This prevents a build up of 

grease, which can be a fire risk. Ensure the external outlet vent does not restrict the 

airflow in any way, as this may result in reduced performance. 

 

3.  Harvey Norman Rangehoods must be ducted in duct work equivalent to the outlet of the 

rangehood ie: The cross sectional area of the rangehood outlets and the duct work must 

be equal. Do not reduce the duct size or have sharp bends. Enlarge the duct size if the 

duct is to run 6 metres or longer. Advice from Qasair is available to ensure optimum 

performance. Always use non-flammable materials to minimise the risk of fire in the duct 

at a later date. 

 

4.  Ensure ducting used for HNE & HNR is a minimum size of ø200 per fan. 

 

5.  Always adequately ventilate the room when the rangehood is in use at the same time as 

appliances burning gas or other fuels. 

 

 

Содержание Harvey Norman HNE Series

Страница 1: ...Harvey Norman HNE HNR Undercupboard Rangehoods Installation Instructions User Guide...

Страница 2: ......

Страница 3: ...1 The installation of Harvey Norman Rangehoods must comply with the information in this booklet 2 Every Harvey Norman Rangehood must be ducted to the outside atmosphere by the use of metal rigid duct...

Страница 4: ...wledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety e Children should be supervised to ensure that they do not play w...

Страница 5: ...mm 250 x 585mm HNR 90L 1 T 240 x 880mm 280 x 900mm 295 x 910mm 250 x 885mm HNR 90L 2 T 240 x 880mm 280 x 900mm 295 x 910mm 250 x 885mm HNE 60L 1 T 340 x 570mm 380 x 600mm 395 x 610mm 350 x 575mm HNE 9...

Страница 6: ...gehood into the cut out Ensure spring brackets are positioned on top of cupboard base Turn screw C clockwise to align rangehood with cupboard base 4 Do not over tighten 5 Tighten screw A by turning cl...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ...exposed in Alfresco areas we recommend spraying the hood with vegetable oil and rubbing it all over the rangehood if it is going to be unused over a period of time FILTER CLEANING For the best results...

Страница 11: ...QASAIR Ducting...

Страница 12: ...l Vent 200 123 CH 200 Chairman s Hat 200 124 CH 200 CB Chairman s Hat 200 Colourbond 127 BD SQ RC 200 Back Draft Roof Cowl Single Motor 200 142 FRC 200 SS Fire Rated 200 Roof Cowl 445M2 Stainless Stee...

Страница 13: ...232 CH 300 Chairman s Hat 300 233 CH 300 CB Chairman s Hat 300 Colourbond 234 BD SQ RC 300 Back Draft Roof Cowl 300 256 BD WV 300 Back Draft Wall Vent 300 263 FRC 300 SS Fire Rated 300 Roof Cowl 445M2...

Страница 14: ...ested To clean filter regularly by handwashing or placing in a dishwasher at least once a month To turn rangehood off after each use Note Warranty under the cleaning page Where a claim is made under w...

Страница 15: ...urner or a total mega joule rating In practice any barbecue or outdoor cooking appliance over 50 mega joules will need a specially made rangehood with an air movement exceeding 2000 cubic meters per h...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...au NSW ACT T 02 9316 4599 F 02 9316 9299 Email salesnsw qasair com au QLD T 07 3423 3503 F 07 3282 9122 Email salesqld qasair com au SA NT T 1300 360 563 F 03 9482 7011 Email salessa qasair com au TAS...

Отзывы: