4.

 

Fit the Qardio Arm on the upper arm 

5.

 

With the Qardio app open, touch your device on the QardioArm to perform the pairing of your 
QardioArm with your phone or tablet. You should accept the pairing request. 

6.

 

On the Qardio app, press the green START button to initiate the blood pressure measurment. 
Blood pressure can be affected by the position of the cuff and your physiologic condition. It is 
very important that the cuff is correctly placed, please read the 

Detailed instructions on correct 

cuff placement

 and the 

Checklist for measuring your blood pressure correctly and reliably

 

sections of this User Guide with particular care. 

Detailed instructions on correct cuff placement 

1.

 

Ideally, remove close-fitting garments from the upper arm, or ensure that rolling the sleeve up 
does not cause constriction. If you are unable to remove or roll-up your shirtsleeve, then ensure 
it remains flat under the cuff.  

2.

 

Always ensure that the cuff fits correctly, verifying the markings on the cuff. You should fit the 
cuff closely, but not too tight.  

3.

 

Make sure that the cuff is positioned 2cm (0.8in) above the elbow. The QardioArm must be 
positioned over the artery that runs down the inner side of the arm. The Qardio logo should be 
on the bottom, towards your hand. Support your arm so it is relaxed, and ensure that the 
QardioArm is at the same height as your heart. Your arm should lightly bend while taking the 
measurement. 

 

Body Posture 

Sitting Comfortably During Measurement 

1.

 

Be seated with your feet flat on the floor without crossing your legs. 

2.

 

Place your hand, palm-side up, in front of you on a flat surface such as a desk or a table. 

3.

 

The middle of the cuff should be at the level of the right atrium of your heart.  

Lying Down During Measurement  

1.

 

Lie on your back. 

2.

 

Place your arm straight along your side with your hand palm-side up. 

3.

 

The cuff should be placed at the same level as your heart. 

 

Note: Blood pressure can be affected by the position of the cuff and your physiologic condition.  

Содержание QardioArm A100

Страница 1: ...QARDIO QardioArm A100 A Smarter Read on Blood Pressure User Guide Draft 0 9 drawings to be replaced not paginated and not formatted...

Страница 2: ...is device is not intended to be a diagnostic device Contact your physician if hypertensive values are indicated The cuff circumference is limited to 22cm 37cm 8 7in 14 6in Important safety information...

Страница 3: ...nder the cuff 2 Always ensure that the cuff fits correctly verifying the markings on the cuff You should fit the cuff closely but not too tight 3 Make sure that the cuff is positioned 2cm 0 8in above...

Страница 4: ...re the measurement Always measure on the same arm normally left or as instructed by your doctor Ideally remove close fitting garments from the upper arm or ensure that rolling the sleeve up does not c...

Страница 5: ...subject to wide fluctuations throughout the day depending on various potential factors including physical exertion and condition You should routinely take your measurements in quiet conditions when yo...

Страница 6: ...mpartment 3 Put the batteries compartment hatch back in place pushing until it clicks in place 4 You will see a green light shining through the batteries compartment hatch Resetting the pairing In ord...

Страница 7: ...pressure Do not take measurement immediately after bathing drinking alcohol smoking exercising or eating Do not use the QardioArm blood pressure monitor while operating a mechanical vehicle or in a mo...

Страница 8: ...ed for a long period of time the batteries should be removed Store the device and the components in a clean dry and safe location Error messages and troubleshooting Problem Cause Remedy START button i...

Страница 9: ...and correct if required 3 Replace the AAA alkaline cells Each measurement has significantly different results Under normal measuring circumstance the reading at home is different from that of the clin...

Страница 10: ...user must deliver it to the able collecting centers for electric and electronic garbage or give back to the retailer when purchasing a new device Disposing of the product separately prevents possible...

Страница 11: ...gnetic Compatibility FCC Rule Part 15 247 Cat DSS Bluetooth FCC Rule Part 15 247 Cat DTS BT4 0 EN ISO 10993 1 2009 Biological evaluation of medical devices Part 1 Evaluation and testing within a risk...

Страница 12: ...s must follow the specific operating instructions for satisfying RF exposure compliance This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Indust...

Страница 13: ...uld be used no closer to any part of the device including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter The device is inte...

Страница 14: ...l Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors a...

Страница 15: ...istered in the U S and other countries The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Qardio Inc is under license Other trademarks...

Отзывы: