- 3 -
When the product is used in a three-phase circuit, verify the electrical conformity and
compatibility of the three-phase circuit.
Verify that the three phases work, and balance the loads between the three phases.
Verify that the neutral and earth work.
Never try to emulate a 230 V circuit connecting an apparatus to two live wires of a 120 V three-phase circuit.
Never try to emulate a 200 V circuit connecting an apparatus to two live wires of a 100 V three-phase circuit.
Always interconnect a Class C circuit breaker between the product and the mains supply.
The circuit breaker current rating depends on the mains voltage rating, as follows:
100-120 V: 30 A
200-240 V: 16 A
Electrical generator
You must power on the generator before powering on the product. Verify that the product is turned off
before powering on the generator.
Terminals marked with the lightning flash symbol are HAZARDOUS LIVE.
The external wiring connected to these terminals requires installation by an instructed person or the use of
ready-made leads or cords.
Never attempt to touch any exposed speaker wiring while the product is operating: first disconnect the
connector from the product.
Mute all output channels before connecting a speaker to an amplified controller.
Do not connect a speaker output in parallel or series with any output of another amplified controller.
Do not connect the speaker outputs to any other voltage source, such as a battery, power mains, or power
supply, regardless of whether the amplified controller is turned on or off.
Never incorporate equipment or accessories not approved by QANON AUDIO.
Read all the related PRODUCT INFORMATION documents shipped with the products before exploiting the system.
Beware of sound levels.
Do not stay within close proximity of loudspeakers in operation.
Loudspeaker systems are capable of producing very high sound pressure levels (SPL) which can instantaneously lead to
permanent hearing damage to performers, production crew and audience members. Hearing damage can also occur at
moderate level with prolonged exposure to sound.
Check the applicable laws and regulations relating to maximum sound levels and exposure times.
Beware of over power risks
.
Only use compatible loudspeakers with appropriate presets to avoid damage to the loudspeakers.
。
Inspect the product before operation.
If any sign of defect or damage is detected, immediately withdraw the product from use for maintenance.
This product is intended for use by trained personnel.
Do not use the product outside its operating temperature range.
The product operates at a room temperature between 0° C / 32° F and 50° C / 122° F. Do not expose the product to
direct sun.
Only use the product in a conformed electro-magnetic environment
.
Conformed environments are: E1 (residential), E2 (commercial and light industrial), E3 (urban outdoors), E4
(controlled EMC environment, ex. TV studio), E5 (heavy industrial), as per EN55103-2 standards.