background image

QT‐AD10 Module 

 

6

AD10 Transmitter Module 

Introduction 

 

AD10 series bodypack transmitters deliver impeccable audio quality and RF performance with wide‐
tuning, High Density (HD) mode, and encryption. The transmitter module features durable metal 
construction, and  single pin Lemo  connector. 

The Q5X remote control system is referred to as 

RCAS

R

emote 

C

ontrol 

A

udio 

S

ystem.  Q5X pioneered 

wireless remote control for transmitters in 2009.  Since this is a wireless control system, it will work 
through walls, clothing, uniforms, costumes, etc. and over longer distances than non‐RF types of 
transmitter control systems on the market.  RCAS consists of 4 main components; 
 

1) a QT‐AD10 series transmitter,  
2) the MicControl software, 
3) the QG‐N3 MicCommander, a network enabled controller, 
4) the QG‐H2 MicCommander, a hand held remote control, with USB connectivity 

 
The 

QG‐H2

 MicCommander is a handheld, stand alone device used to control the QT‐AD10 series of 

Q5X audio transmitters, such as the QT‐AD10 PlayerMic.  It can also control legacy QT‐5000 
transmitters.  The QG‐H2 allows the user to view, monitor and make adjustments to any QT‐AD10 
transmitter within the control range. It can monitor and/or adjust; the transmitter power state ON or 
OFF, RF power, UHF frequency, microphone muting and mic gain, groups, transmitter naming, and 
other operational parameters can be remotely configured using the QG‐H2 without physical access to 
the transmitter. 
 
The 

QG‐H2

 can control up to 32 transmitters as a stand‐alone device. 

USB connectivity allows the 

QG‐H2

 to be connected to a laptop or PC running Windows 7 and above.  

This connection allows the use of the 

MicControl

 software on the PC to control enhanced features of 

the transmitters including the ability to name transmitters.  Naming transmitters makes it much 
easier to manage the system, for example instead of looking at a list of serial numbers like 10223 or 
20567 you can now name them Player1 or Actor 2 or Joes Mic. 
 
The 

RCAS

 system can also be networked and uses the network enabled 

QG‐N3

 to remotely control 

the 

QT‐AD10

 series of transmitters via 

MicControl

 software which can be installed on a Windows PC 

or laptop.  Multiple QG‐N3 units can be added to a network to manage large area installations. 
The 

MicControl

 software can control over 300 transmitters for larger installations. 

 
The 

QG‐H2MicCommander

 operates independently from any other gateway or computer. It 

communicates one‐to‐one with each transmitter and allows access to all necessary settings through a 
simple interface.  It can over ride any setting made by the 

MicControl

 software and vice versa. 

 
The 

QG‐H2 and QG‐N3

 offer the following benefits: 

Содержание AquaMic QT-AD10A

Страница 1: ...QT AD10 Module Description This document describes the use of the QT AD10A C transmitter History Rev 1 Original ...

Страница 2: ...n 6 Features 7 Performance 7 Design 7 Working with the AD10 Module 7 Out of the Box Setup 7 Storage Mode 7 Standby Mode 8 Run Mode 8 Control and Configuration of Modules 8 Adjusting Module Parameters 8 Specifications 11 Input Connector Diagrams 11 Frequency Bands and Transmitter RF Power 12 LICENSING INFORMATION 12 Certifications 12 ...

Страница 3: ...ser is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Wireless microphone users...

Страница 4: ...IC 4614A QTAD10A IC 4614A QTAD10C a été approuvé par Innovation Sciences et Développement économique Canada pour fonctionner avec les types d antenne énumérés ci dessous et ayant un gain admissible maximal Les types d antenne non inclus dans cette liste et dont le gain est supérieur au gain maximal indiqué pour tout type figurant sur la liste sont strictement interdits pour l exploitation de l éme...

Страница 5: ...ule shall be tested to comply with all applicable FCC requirements and Unintentional radiators FCC section 15 107 15 109 and ISED ICES 003 before declaring compliance to Part 15 of the FCC Rules and ISED ICES 003 The module integrator may not 1 Alter modify or remove the module case 2 Make changes to the Circuit Card Assembly of the module 3 Remove change or alter the integrated UHF antenna or the...

Страница 6: ...F RF power UHF frequency microphone muting and mic gain groups transmitter naming and other operational parameters can be remotely configured using the QG H2 without physical access to the transmitter The QG H2 can control up to 32 transmitters as a stand alone device USB connectivity allows the QG H2 to be connected to a laptop or PC running Windows 7 and above This connection allows the use of t...

Страница 7: ...mal coverage low latency o High density dramatic increase in max system channel count Built in tone generator and RF markers to facilitate walk testing Switchable Power Levels 2 10 20mW region dependent Design Single pin Lemo audio connector Rugged metal construction Flexible wave antenna Working with the AD10 Module Out of the Box Setup Ensure the QT AD10 has a sufficient charge level by first co...

Страница 8: ...nge parameters and to turn to the standby mode or storage mode Control and Configuration of Modules The QG H2 is required to view monitor and make adjustments to any QT AD10 transmitter within the control range It can monitor and or adjust the transmitter power state ON or OFF RF power UHF frequency microphone muting and mic gain groups transmitter naming and other operational parameters can be re...

Страница 9: ... a muted mic such as the QT AD10 RefMic with it s integrated mute switch or to remotely mute a mic whenever required Mic Gainoffsetis used to match Audio Levels of different types of Microphones When pairing two or more transmitters to a single receive channel there may be a difference in volume levels between microphones or instruments If this occurs use the Offset function to match the audio lev...

Страница 10: ...electing the desired value A lower power level will conserve battery life 2 4 GHz Chthe RCAS control channel default is 25 change this on the transmitter only if you are having control issues that can be seen when you have completed a 2 4GHz Spectrum scan See Device Configuration the 2 4 GHz Telemetry section below for detailed instructions Storage Mode Will configure the AT AD10 to it s off mode ...

Страница 11: ...ity Mode 125 KHz Modulation Type Shure Axient Digital Proprietary RF Output Power 2 mw 10 mw 20 mw Avg Antenna Type 1 4 wave Antenna Impedance 50 Ohm Housing Machined Aluminum Operating Temperature Range 20 C to 50 C Storage Temperature Range 20 C to 45 C Package Size Dimensions H W D Weight PlayerMic S 11 5 mm 41 5 mm x 74 5 mm 45 in 1 6 in 2 9 in 48 7 g 1 72 oz PlayerMic 11 5 mm 41 5 mm 93 5 mm ...

Страница 12: ...ability depends on the user s classification and application and on the selected frequency Q5X strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing and before choosing and ordering frequencies Certifications Certified under FCC Part 15 Subpart C section 15 247 and Part 74 FCC ID Q5N QTAD10A and FCC Part 15 Subpart C section 15 247 and Part 74 ...

Отзывы: