QSD2316L DVR User’s Manual
27
3.3.5 Alarm Recording
This unit supports recording channels and PTZ linking after alarm.
STEP1
Enter ALARM configuration, see Fig 3.13 Sensor Alarm Setup. Select cameras
Fig 3.13 Sensor Alarm Setup
STEP2
Enable Detection first. Set Device type.
STEP3
Enter Trigger configuration. Set alarm out, recording cameras and linked PTZ, referring to 3.3.4 Motion
Detection Recording STEP4-5
STEP4
Set Alarm in hold time. It is the interval time between the two adjacent efficient alarms. This is similar with
Hold time in MOTION configuration.
STEP5
Set Alarm out hold time and Buzzer hold time. Click OK to save settings
STEP6
Enter SCHEDULE configuration. Select Sensor and relative cameras to set, referring to 3.8 Schedule
Setup.
Note: About preset and auto cruise, users can only select one at same time.
The actual post alarm record time equals Hold time in RECORD and Hold time in MOTION