Validity

These instructions are only valid for crystalline solar modules from 
the company Q CELLS as specified at chapter „2.1 Technical 
Specifications“. Q CELLS assumes no liability for damage resulting 
from failure to observe these instructions. 

 

Ä

Please observe the wiring and dimensioning of the system.

 

Ä

The installer of the system is responsible for compliance with all 
necessary safety regulations during set-up and installation.

Q CELLS assumes no liability on the basis of these instructions. 
Q CELLS is only liable in the context of contractual agreements 
or in the context of accepted guarantees. Q CELLS accepts no 
other responsibility for the functionality and safety of the modules. 

 

Ä

Please observe the instructions for any other system compo-
nents that may be part of the complete solar power system. 
It may be necessary to carry out a structural analysis for the 
entire project. 

 

Ä

If your questions are not satisfactorily answered in the manual, 
please contact your system supplier.

Additional information can be found on our website at 
www.q-cells.com.

Information for the Operator

 

Ä

Please keep this installation manual for the entire life of the 
solar power system.

 

Ä

Please contact your system supplier for information concerning 
the formal requirements for solar power systems.

 

Ä

Please be sure to contact the relevant local authorities and 
energy providers regarding regulations and permit requirements 
prior to installation of the solar power system. Your financial 
success depends on the fulfillment of these requirements.

Other applicable documents

This installation manual is only valid in combination with the following 

technical information.

DOCUMENT TYPE

Product data sheet

Packaging and transport information

MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS THE 
LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD 
AND RISK PROPERTY DAMAGE. THIS INCLUDES IMPROPER 
INSTALLATION OR CONFIGURATION, IM PROPER MAINTENANCE, 
UNINTENDED USE, AND UNAUTHORIZED MODIFICATION.

Fig. 1: 

External dimensions (in inch (mm)) and components for  
Q.PEAK DUO L-G5.3/BF

39.4"
(1000 mm)

51.5" (1308 mm)

79.3" (2015 mm)

1.38" (35 mm)

4 × Mounting slots (DETAIL A)

8 × Drainage holes  

Frame

DETAIL A

0.63" (16 mm)

0.33" (8.5 mm)

1.0" (25.5

 mm)

37.4"
(949 mm)

DETAIL B

0.39" (10 mm)

0.28" (7 mm)

0.98" (25

 mm)

4 × Mounting slots system Tracker (DETAIL B)

37.4"

(950 mm)

15.7" (400 mm)

13.9" (353 mm)

Label

4 × Grounding holes, Ø 0.18" (4.5 mm)

4 × Drainage holes

≥ 17.7" (450

 mm)

≥ 7.9" (200

 mm)

For additional information see the relevant datasheet of the module provided at www.q-cells.com.

PRODUCT LINE

Q.PEAK DUO L-G5.3/BF

Type

Q.ANTUM DUO

Length [in]

79.3  (2015 mm)

Width [in]

39.4  (1000 mm)

Frame height [in]

1.38  (35 mm)

Area [yd²]

2.42  (2.02 m²)

Weight [lbs]

57.3  (26.0 kg)

Max. system voltage V

SYS

1500 V  (IEC) / 1500 V  (UL)

Max. series fuse rating

20 A

Permissible temperature range

–40 °F bis +185 °F (–40 °C to +85 °C)

Junction box protection class

≥ IP67 with bypass diode

Connector protection class

IP67 or IP68

Fire protection class

B / TYPE 22 (New Type is similar to Type 10 but with metallic frame)

Max. test load  
Push/Pull

1

 [lbs/ft²]

113 / 50
(5,400 Pa / 2,400 Pa)

Max. design load  
Push/Pull

1

 [lbs/ft²]

75 / 33
(3,600 Pa / 1,600 Pa)

Middle rail

No

Certificates

CE-compliant; IEC 61215:2016; IEC 61730:2016; Application Class II; UL 1703

1

  Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section „2.3 Mounting Options“)

INTRODUCTION

PLANNING

2.1  TECHNICAL SPECIFICATIONS

Содержание Q.PEAK DUO L-G5.3/BF

Страница 1: ...Valid for North America INSTALLATION AND OPERATION MANUAL Q PEAK DUO L G5 3 BF solar modules...

Страница 2: ...operator are responsible for com pliance with all applicable statutory requirements and regulations The following regulations and standards must be upheld at all times during the installation operatio...

Страница 3: ...ulfillment of these requirements Other applicable documents This installation manual is only valid in combination with the following technical information DOCUMENT TYPE Product data sheet Packaging an...

Страница 4: ...with IEC 61215 and Design Load 1 5 in accordance with UL 1703 Installation using a mounting structure for solar modules Mounting Structure Requirements Requirements for the mounting structure Conform...

Страница 5: ...ubconstruction Mounting profile TYPE OF INSTALLATION POINT MOUNTING SYSTEM LINEAR MOUNTING SYSTEM INSTALLATION WITH CLAMPS HYBRID CLAMPING INSTALLATION ON MOUNTING POINTS 2 PLANNING 2 3 MOUNTING OPTIO...

Страница 6: ...system supplier The Q CELLS listed test load values were determinded with the following clamp parameters clamp width 1 58in 40mm and clamp depth 0 39in 10mm The system installer is responsible for the...

Страница 7: ...deter mining the maximum number of modules in the string Parallel Connection Modules may be damaged by the occurrence of reverse currents caused by module defects ground leaks or defective insulation...

Страница 8: ...n NOTE Module damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects to fall onto modules 3 INSTALLATION 3 1 SAFETY AND TRANSPORT DANGER Risk o...

Страница 9: ...arcs may result from the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the ent...

Страница 10: ...odules proceed in reverse order DANGER Risk of fatal injury due to electric shock Electrical work may only be performed by qualified and skilled personnel see page 3 Ensure correct polarity Use solar...

Страница 11: ...nt electrical shock or fire the frame of the module as well as any non current carrying metal parts of the system must be grounded While this section provides some information about grounding the Q CE...

Страница 12: ...Equipment Grounding Conductor Aluminum Frame Screw Stainless Steel Q CELLS solar modules are known for a long operating life and minimal maintenance effort and expense Dirt and grime are usually washe...

Страница 13: ...A 92618 USA TEL 1 949 748 59 69 EMAIL inquiry us q cells com WEB www q cells us Subject to change without notice Q CELLS Installation manual solar modules Q PEAK DUO L G5 3_BF_2020 08_Rev02_NA 24 INST...

Отзывы: