background image

SIMATIC Industrial PC SIMATIC Panel PC 677B 

______________
______________
______________
______________
______________
______________

 

 

Safety 

 

1

Delivery 

 

2

Installation / panel-mounting

 

3

Connecting 

 

4

Commissioning 

 

5

Service and support 

 

6

SIMATIC 

Industrial PC 

SIMATIC Panel PC 677B 

Operating Instructions (Compact) 

06/2008 

A5E02217246-01 

 

Содержание PC 677B

Страница 1: ...________ ______________ ______________ ______________ ______________ Safety 1 Delivery 2 Installation panel mounting 3 Connecting 4 Commissioning 5 Service and support 6 SIMATIC Industrial PC SIMATIC Panel PC 677B Operating Instructions Compact 06 2008 A5E02217246 01 ...

Страница 2: ...ation of a device system may only be performed by qualified personnel Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Prescribed Usage Note the following WARNING This device may only be used for the applic...

Страница 3: ...eparing the mounting cut out 11 3 4 Securing the device with clamps 13 3 5 Securing with screws 14 4 Connecting 17 4 1 Connection elements and operator controls 18 4 2 Connecting the 120 V 240 V AC power supply 20 4 3 Connecting the 24 V DC power supply 22 4 4 Connecting the Equipotential Bonding Circuit 23 5 Commissioning 25 5 1 Initial Startup 25 5 2 Setting up the language selection 26 5 3 Sett...

Страница 4: ......

Страница 5: ...ment on the machine or the system is necessary to avoid endangering persons With this especially the programming configuration and wiring of the inserted I O modules have to be executed in accordance with the safety performance SIL PL or Cat identified by the necessary risk analysis The intended use of the device has to be ensured The proper use of the device has to be verified with a function tes...

Страница 6: ...Safety SIMATIC Panel PC 677B 6 Operating Instructions Compact 06 2008 A5E02217246 01 ...

Страница 7: ...rial in case you have to transport the unit again NOTICE The packaging protects the device during transport and storage Therefore never dispose of the original packaging material 5 Please keep the enclosed documentation in a safe place You will need the documentation when you start up the device for the first time 6 Check the contents of the package for completeness and transportation damage Check...

Страница 8: ...Package with Windows 2000 XP Professional Microsoft Windows Product Key from Certificate of Authenticity COA The label is attached to the device Ethernet address BIOS Setup F2 key under Main Hardware Options Ethernet Address 2 3 Product Documentation The detailed operating instructions for Panel PC 677B can be downloaded as a PDF file on the Internet under the following address http www siemens co...

Страница 9: ...th operator control units Depth D Key panel with 12 TFT 105 mm Key panel with 15 TFT 124 mm Touch panel with 12 TFT 123 mm Touch panel with 15 TFT 121 mm Touch panel with 17 TFT 130 mm Touch panel with 19 TFT 130 mm Note Additional mounting depth with optical drive The installation depth increases by 21 mm when an optical drive is installed in the device ...

Страница 10: ...sitions Approval Only certain mounting positions are approved for the device Figure 3 1 Mounting position Table 3 1 Permissible deviations from the vertical mounting position Temperature Angle A Angle B to 45 C 20 20 Note When mounting the device at an angle note the following Do not subject the device to mechanical stress Operation of a DVD drive is not permitted ...

Страница 11: ... shows the dimensions for the mounting cut out PP 6 6 6 6 6 6 6 Figure 3 2 Drill holes for the screws and pressure points for the clamp screws 1 Drill hole for screw attachment 4 Clamp 2 Pressure points for clamp 5 RZ 120 in the seal area 3 Setscrews 6 Seal area Note Mounting dimensions can be read from the dimension overview or they can be transferred to the cabinet from the mounting template sup...

Страница 12: ...112 112 112 16 16 16 16 10 10 10 10 19 81 46 46 35 81 46 46 56 56 33 33 1 M6 thread or drill holes with a diameter of 7 mm 2 Cut outs for the shafts of the insert strips are only necessary for 15 key panels 3 Two clamps necessary for vertically securing clamps for 17 and 19 touch panels only Preparing the mounting cut out Steps for preparing the mounting cut out 1 Select a location suitable for mo...

Страница 13: ... of protection The plant builder is responsible for the correct installation of the device The degree of protection IP65 is only guaranteed for the front of the device if the ring seal is properly applied with the correct size of cutout the unit has been clamped in place and the instructions below are observed NOTICE Control cabinet installation Material strength at the mounting cut out Ensure tha...

Страница 14: ...ith order number 6AV7672 8KE00 0AA0 are required on the front Drill holes in the control unit Steps for drilling holes 1 Drill holes Ø approx 2 5 mm from the rear in the four recesses of the control unit 2 Drill these holes with a diameter of Ø 5 5 mm for M5 and a Ø 6 5 mm for M6 3 Deburr the holes from the front of the control unit NOTICE Risk of damage Ensure that no metal cuttings enter the dev...

Страница 15: ...he IP54 degree of protection is guaranteed for mounting together with the ring seal CAUTION Observe the panel seal when mounting Ensure you do not damage the panel seal when mounting the device NOTICE Control cabinet installation Material strength at the mounting cut out Ensure that the material strength at the mounting cut out is a minimum of 2 mm and a maximum of 6 mm Please follow the specifica...

Страница 16: ...Installation panel mounting 3 5 Securing with screws SIMATIC Panel PC 677B 16 Operating Instructions Compact 06 2008 A5E02217246 01 ...

Страница 17: ...SIMATIC Panel PC 677B Operating Instructions Compact 06 2008 A5E02217246 01 17 Connecting 4 ...

Страница 18: ...r via DVI VGA adapter 3 Compact Flash Slot for Compact Flash card 4 COM 1 Serial interface RS232 9 pin D sub connector 5 USB 4 USB 2 0 interfaces 2 interfaces can be simultaneously used as high current 500 mA outputs 6 Ethernet 2 RJ45 connections for 10 100 Mbps 7 PROFIBUS DP MPI MPI interface RS485 electrically isolated 9 pin D sub plug 8 On Off switch 9 100 240 V AC or 24 V DC Connection for AC ...

Страница 19: ...B interface is removed in order to connect a USB component the IP65 degree of protection for the device is no longer guaranteed Note Use of USB devices Wait at least ten seconds between removal and reconnection of USB devices This also applies to control units with touch screen panels especially for touch operation When using standard USB peripherals bear in mind that their EMC immunity level is f...

Страница 20: ...ust conform with local mains voltage CAUTION The mains connector must be disconnected to fully isolate the device from the mains Ensure easy access to this area A master mains disconnect switch must be installed if the device is mounted in a switch cabinet Always ensure free and easy access to the power inlet on the device or that the safety power outlet of the building installation is freely acce...

Страница 21: ...e used The connector must be compliant with NEMA 5 15 120 VAC power supply Use a flexible power cord which is approved to UL and CSA and which has the following features Type SJT with three leads min 18 AWG conductor cross section max 4 5 m in length and parallel ground contact connector 15 A min 125 V 240 VAC power supply Use a flexible power cord which is approved to UL and CSA and which has the...

Страница 22: ...e extra low voltage SELV in addition a protective conductor must be connected The conductors must withstand the short circuit current of the 24 V DC power source so that a short circuit will not damage the cable Only connect cables with a minimum cross section of 1 3 mm2 AWG16 and a maximum cross section of 3 3 mm2 AWG12 NOTICE The 24 V DC power supply must match the power consumption of the devic...

Страница 23: ...harged to ground The equipotential bonding connection of the device is located underneath the device and is identified by the following symbol Figure 4 1 Equipotential Bonding Connecting the Equipotential Bonding Circuit You require a TORX T20 screwdriver to connect the equipotential bonding conductor Steps for connecting the equipotential bonding 1 Connect the equipotential bonding connection M4 ...

Страница 24: ...Connecting 4 4 Connecting the Equipotential Bonding Circuit SIMATIC Panel PC 677B 24 Operating Instructions Compact 06 2008 A5E02217246 01 ...

Страница 25: ...The module carries out a self test The following message appears Press F2 to enter Setup or ESC to show Boot menu 2 Wait for the message to disappear 3 Follow the instructions on the screen NOTICE The device may not be switched off at any time during the installation process Do not change the default BIOS settings otherwise the operating system setup may become corrupted 4 When you have entered al...

Страница 26: ...up the language selection The Multilanguage User Interface MUI allows you to set up the Windows 2000 Windows XP Professional Windows Vista menus and dialogs for additional languages Windows 2000 and Windows XP The default language setting of your MUI installation is English with US keyboard layout You can change the language in the Control Panel Select Start Settings Control Panel Regional and Lan...

Страница 27: ...46 01 27 5 3 Setting the panel type After the device is restarted different dialogs appear on the screen Drivers and applications can be installed from these dialogs 1 In the Panel Wizard dialog click the type of panel that corresponds to your device Figure 5 1 Panel type 2 Follow the instructions on the screen ...

Страница 28: ...ction that prevents two function keys from being activated simultaneously This prevents incorrect operations and undefined states of the user program Note For a detailed description of the SIMATIC KeyTools refer to the help menu and the application description on the Documentation and Drivers CD Calling up KeyTools 1 Select Start Settings Control Panel SIMATIC KeyTools 2 Select the desired applica...

Страница 29: ... for touch panel device You can operate the device by means of a virtual screen keyboard You can use it to enter the characters directly on the touch panel or with an externally connected mouse Call Touch input Start the Touch input application on the desktop The screen keyboard is displayed 1 Button for language selection German English Italian Spanish French ...

Страница 30: ...Commissioning 5 5 On screen keyboard for touch panel device SIMATIC Panel PC 677B 30 Operating Instructions Compact 06 2008 A5E02217246 01 ...

Страница 31: ...ation mall Training All the training options are listed at http www siemens com sitrain Find a contact at Phone 49 911 895 3200 Technical support Tel 49 180 5050 222 Fax 49 180 5050 223 http www siemens com automation csi service A Web form for Support Request can be found at http www siemens com automation support request When you contact the customer support please have the following information...

Страница 32: ... PC 677B 32 Operating Instructions Compact 06 2008 A5E02217246 01 After sales information system for SIMATIC PC PG Information about contacts drivers and BIOS updates FAQs and Customer Support can be found at http www siemens com asis ...