10
Adjustable power factor range
0.95~1~0.95
Feed-in phases/connection phases
1/1
Total Harmonic Distortion.
(Total harmonic factor of the output current with total
harmonic factor of the AC voltage < 2%,
and AC power > 50% of the rated power)
5%
Efficiency (PV to Grid)
European efficiency
95 % (when power is
4600W)
Max. efficiency
95.5 %
Protective Device
DC disconnection device for PV
No
Ground-fault monitoring/grid monitoring
Yes/Yes
General Data
Dimensions (W/H/D)
1000/680/267 mm
Weight
95 kg
Protective class (I, II, III)
Class I
Degree of protection
IP21
Max. permissible value for relative humidity
95 % (non-condensing)
Operating temperature
-10~40°C
Storage temperature
-20~60°C
Noise emission
≤
50dB(A) @ 1m
Over voltage category
III
Features
Display
Custom LCD
Communication
LAN, RS485
Energy management system
Integrated
Certificates and approvals
IEC 62109-1, IEC 62109-2
ER-G83/2, ER-G59/3
(*) : It can be set 3600W or 4600W by software when installing.