Warranty Information

Confidentiality

The information contained in this manual may be confidential and proprietary and is the property of Pyxis
Lab, Inc. Information disclosed herein shall not be used to manufacture, construct, or otherwise reproduce
the goods described. Information disclosed herein shall not be disclosed to others or made public in any
manner without the express written consent of Pyxis Lab, Inc.

Standard Limited Warranty

Pyxis Lab warrants its products for defects in materials and workmanship. Pyxis Lab will, at its option, repair
or replace instrument components that prove to be defective with new or remanufactured components
(i.e., equivalent to new). The warranty set forth is exclusive and no other warranty, whether written or oral,
is expressed or implied.

Warranty Term

The Pyxis warranty term is thirteen (13) months ex-works. In no event shall the standard limited warranty
coverage extend beyond thirteen (13) months from original shipment date.

Warranty Service

Damaged or dysfunctional instruments may be returned to Pyxis for repair or replacement. In some in-
stances, replacement instruments may be available for short duration loan or lease.

Pyxis warrants that any labor services provided shall conform to the reasonable standards of technical com-
petency and performance effective at the time of delivery. All service interventions are to be reviewed and
authorized as correct and complete at the completion of the service by a customer representative, or des-
ignate. Pyxis warrants these services for 30 days after the authorization and will correct any qualifying
deficiency in labor provided that the labor service deficiency is exactly related to the originating event. No
other remedy, other than the provision of labor services, may be applicable.

Repair components (parts and materials), but not consumables, provided during a repair, or purchased
individually, are warranted for 90 days ex-works for materials and workmanship. In no event will the in-
corporation of a warranted repair component into an instrument extend the whole instrument’s warranty
beyond its original term.

Warranty Shipping

A Repair Authorization (RA) Number must be obtained from Pyxis Technical Support before any product can
be returned to the factory. Pyxis will pay freight charges to ship replacement or repaired products to the
customer. The customer shall pay freight charges for returning products to Pyxis. Any product returned to
the factory without an RA number will be returned to the customer. To receive an RMA you can generate a
request on our website at

https://pyxis-lab.com/request-tech-support/

.

Pyxis Technical Support

Contact Pyxis Technical Support at +1 (866) 203-8397,

[email protected]

or by filling out a request for

support at

https://pyxis-lab.com/request-tech-support/

.

LS-200 User Manual

[email protected]

| +1 (866) 203-8397

1

Содержание 54011

Страница 1: ......

Страница 2: ...00 Ultrasonic Level Sensor User Manual September 28 2020 Rev 1 02 Pyxis Lab Inc 1729 Majestic Dr Suite 5 Lafayette CO 80026 USA www pyxis lab com 2017 Pyxis Lab Inc Pyxis Lab Proprietary and Confident...

Страница 3: ...6 6 1 Download uPyxis Mobile App 6 6 2 Connecting to uPyxis Mobile App 6 6 3 Overview Screen 7 6 4 Reading Screen 8 6 5 Settings Screen 8 7 Setup with uPyxis Desktop App 9 7 1 Install uPyxis Desktop A...

Страница 4: ...elivery All service interventions are to be reviewed and authorized as correct and complete at the completion of the service by a customer representative or des ignate Pyxis warrants these services fo...

Страница 5: ...4 20mA Analog Output RS 485 Digital Output with Modbus protocol Installation 1 male NPT Cable Length 9 8 ft 3 m extension cable available Power Supply 24 VDC 2 W Dead Zone 4 inch 10 cm Dimension H Di...

Страница 6: ...dimensions of the sensor are shown in Figure 2 If a flat horizontal surface is not available on the top of the tank please use a self aligning bulkhead fitting so that the sensor can be adjusted to be...

Страница 7: ...he controller is used make sure that the output from the power supply is rated for 22 26 VDC 65 mA NOTE The negative 24V power terminal power ground and the negative 4 20mA ter minal on the LS 200 are...

Страница 8: ...n LED Power Supply is on Power Supply is off Blue LED Bluetooth is connected Bluetooth is disconnected NOTE The Bluetooth connected LED will illuminate within 30 seconds of powerup of the device This...

Страница 9: ...Connect the LS 200 sensor to a mobile smart phone according to the following steps 1 Open uPyxis Mobile App 2 On uPyxis Mobile App pull down to refresh the list of available Pyxis devices 3 If the con...

Страница 10: ...n When connected the uPyxis Mobile App will default to the OVERVIEW screen The Overview screen displays the current liquid level and volume of liquid remaining Figure 7 LS 200 User Manual service pyxi...

Страница 11: ...or assistance To convert the measured distance to volumetric information the user must enter three parameters via the uPyxis Mobile App s Setting screen Tank Volume rated volume capacity of the tank I...

Страница 12: ...oft Net Framework 4 5 if not installed on the PC before the USB driver for the USB Bluetooth adapter the USB RS485 adapter and the main uPyxis Desktop application Double click the uPyxis Setup exe fil...

Страница 13: ...12 4 If the connection is successful the LS 200 and its Serial Number SN will be displayed in the left pane of the uPyxis window NOTE After the sensor and Bluetooth is powered up it may take up to 10...

Страница 14: ...Figure 13 7 4 Reading Screen The Reading screen displays the current liquid level and the liquid level over time Figure 14 LS 200 User Manual service pyxis lab com 1 866 203 8397 11...

Страница 15: ...e measured distance to volumetric information the user must enter three parameters via the uPyxis Mobile App s Setting screen Tank Volume rated volume capacity of the tank Installation Height from the...

Страница 16: ...ty provided by the tank manufacturer may be greater than the maximum safe net or effective capacity that can be practically filled Please keep this in mind as you configure your LS 200 for practical p...

Страница 17: ...the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is con nected Consult the dealer or an experienced radio T...

Отзывы: