10

Regulatory Approval

United States

The LS-200 sensor has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy, and if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in an installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-

nected.

• Consult the dealer or an experienced radio/TV technician for help

Canada

This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any in-
terference, including interference that may cause undesired operation of the device. Le présent appareil est
conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible

11

Contact Us

Pyxis Lab, Inc

1729 Majestic Dr. Suite 5
Lafayette, CO 80026 USA

www.pyxis-lab.com

Phone: +1 (866) 203-8397
Email:

[email protected]

LS-200 User Manual

[email protected]

| +1 (866) 203-8397

14

Содержание 54011

Страница 1: ......

Страница 2: ...00 Ultrasonic Level Sensor User Manual September 28 2020 Rev 1 02 Pyxis Lab Inc 1729 Majestic Dr Suite 5 Lafayette CO 80026 USA www pyxis lab com 2017 Pyxis Lab Inc Pyxis Lab Proprietary and Confident...

Страница 3: ...6 6 1 Download uPyxis Mobile App 6 6 2 Connecting to uPyxis Mobile App 6 6 3 Overview Screen 7 6 4 Reading Screen 8 6 5 Settings Screen 8 7 Setup with uPyxis Desktop App 9 7 1 Install uPyxis Desktop A...

Страница 4: ...elivery All service interventions are to be reviewed and authorized as correct and complete at the completion of the service by a customer representative or des ignate Pyxis warrants these services fo...

Страница 5: ...4 20mA Analog Output RS 485 Digital Output with Modbus protocol Installation 1 male NPT Cable Length 9 8 ft 3 m extension cable available Power Supply 24 VDC 2 W Dead Zone 4 inch 10 cm Dimension H Di...

Страница 6: ...dimensions of the sensor are shown in Figure 2 If a flat horizontal surface is not available on the top of the tank please use a self aligning bulkhead fitting so that the sensor can be adjusted to be...

Страница 7: ...he controller is used make sure that the output from the power supply is rated for 22 26 VDC 65 mA NOTE The negative 24V power terminal power ground and the negative 4 20mA ter minal on the LS 200 are...

Страница 8: ...n LED Power Supply is on Power Supply is off Blue LED Bluetooth is connected Bluetooth is disconnected NOTE The Bluetooth connected LED will illuminate within 30 seconds of powerup of the device This...

Страница 9: ...Connect the LS 200 sensor to a mobile smart phone according to the following steps 1 Open uPyxis Mobile App 2 On uPyxis Mobile App pull down to refresh the list of available Pyxis devices 3 If the con...

Страница 10: ...n When connected the uPyxis Mobile App will default to the OVERVIEW screen The Overview screen displays the current liquid level and volume of liquid remaining Figure 7 LS 200 User Manual service pyxi...

Страница 11: ...or assistance To convert the measured distance to volumetric information the user must enter three parameters via the uPyxis Mobile App s Setting screen Tank Volume rated volume capacity of the tank I...

Страница 12: ...oft Net Framework 4 5 if not installed on the PC before the USB driver for the USB Bluetooth adapter the USB RS485 adapter and the main uPyxis Desktop application Double click the uPyxis Setup exe fil...

Страница 13: ...12 4 If the connection is successful the LS 200 and its Serial Number SN will be displayed in the left pane of the uPyxis window NOTE After the sensor and Bluetooth is powered up it may take up to 10...

Страница 14: ...Figure 13 7 4 Reading Screen The Reading screen displays the current liquid level and the liquid level over time Figure 14 LS 200 User Manual service pyxis lab com 1 866 203 8397 11...

Страница 15: ...e measured distance to volumetric information the user must enter three parameters via the uPyxis Mobile App s Setting screen Tank Volume rated volume capacity of the tank Installation Height from the...

Страница 16: ...ty provided by the tank manufacturer may be greater than the maximum safe net or effective capacity that can be practically filled Please keep this in mind as you configure your LS 200 for practical p...

Страница 17: ...the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is con nected Consult the dealer or an experienced radio T...

Отзывы: