ST-730 Series Inline Turbidity Probes

User Manual

March 9, 2020

Rev. 1.33

Pyxis Lab, Inc.

1729 Majestic Dr. Suite 5

Lafayette, CO 80026 USA

www.pyxis-lab.com

© 2017 Pyxis Lab, Inc.

Pyxis Lab Proprietary and Confidential

Содержание 53201

Страница 1: ...0 Series Inline Turbidity Probes User Manual March 9 2020 Rev 1 33 Pyxis Lab Inc 1729 Majestic Dr Suite 5 Lafayette CO 80026 USA www pyxis lab com 2017 Pyxis Lab Inc Pyxis Lab Proprietary and Confiden...

Страница 2: ...Download uPyxis Mobile App 7 5 2 Connecting to uPyxis Mobile App 7 5 3 Calibration Screen and Reading 8 5 4 Diagnosis Screen 9 5 5 Device Info Screen 9 6 Setup and Calibration with uPyxis Desktop App...

Страница 3: ...very All service interventions are to be reviewed and authorized as correct and complete at the completion of the service by a customer representative or des ignate Pyxis warrants these services for 3...

Страница 4: ...1 1 0 1 0 05 10 Accuracy 2 of reading Method Nephelometric with white LED and IR LED 860 nm light sources Calibration Two point calibration against standard solution Outputs 4 20mA Analog Output RS 48...

Страница 5: ...Tee O ring and Nut P N ST 001 7 Pin Female Adapter Flying Leads Cable 2 ft P N MA 1100 User Manual available online at www pyxis lab com support html 3 2 Optional Accessories Figure 1 ST 730 Series Us...

Страница 6: ...the ST 730 series probe into the ST 001 Tee Assembly follow the steps below 1 Insert the provided O ring into the O ring groove on the tee 2 Insert the ST 730 series probe into the tee 3 Tighten the t...

Страница 7: ...ustom tee assembly The ST 730SS probe also has four 1 4 28 tapped mounting holes on the base of the sensor Figure 4 Dimension of the ST 730SS mm NOTE It is recommended to install the ST 730 series pro...

Страница 8: ...T 730 series probe to a controller Wire Color Designation Red 24V Black 24V Power ground White 4 20mA Green 4 20mA Blue RS 485 A Yellow RS 485 B Clear Shield earth ground Internally connected to the p...

Страница 9: ...y Figure 7 5 2 Connecting to uPyxis Mobile App Turn on Bluetooth on your mobile phone Do not pair the phone Bluetooth to the ST 730 series probe Open uPyxis Mobile App Once the app is open the app wil...

Страница 10: ...efault to the Calibration screen From the Calibration screen you can perform calibrations by pressing on Zero Calibration Slope Calibration and 4 20mA Span Follow the screen instructions for each cali...

Страница 11: ...well as Export Upload This feature may be used for technical support when communicating with service pyxis lab com Figure 10 5 5 Device Info Screen From the Device Info screen You can name the Device...

Страница 12: ...ver for the USB Bluetooth adapter MA NEB the USB RS485 adapter MA 485 and the main uPyxis Desktop application Double click the uPyxis Setup exe file to install Figure 12 Click Install to start the ins...

Страница 13: ...ormation description for Device Name and Product Name then click Set to save Figure 14 6 4 Calibration Screen To calibrate the device click on Calibration On the Calibration screen there are three cal...

Страница 14: ...instruction on how to calibrate then click Slope Calibration Figure 17 6 4 3 4 20mA Span To perform 4 20mA Span click on 4 20mA Span Then follow the instructions provided to alter the 4 20mA output sp...

Страница 15: ...es probe is configured as a Modbus slave device In addition to the NTU value many op erational parameters including warning and error messages are available via a Modbus RTU connection Contact Pyxis L...

Страница 16: ...nnel These components and more come with a Pyxis Lab Inline Probe Cleaning Solution Kit P N SER 01 which can be purchased at our online Estore Catalog https pyxis lab com product st series probe clean...

Страница 17: ...qualified turbidity standard After properly cleaning the ST 730 series sensor carry out the zero point and slope calibration using the qualified turbidity standard Pyxis Lab Turbidity Standards can be...

Отзывы: