VOCALISER INSTALLATION MANUAL
RINS119-5 Page: 15
7 . 2 T h e Ou tp u t 1 S ta t e ( F L T )
At default the FLT output is programmed as
negative applied.
The following states can be
chosen for this output:
State Output Type
“OFF State”
“ON State”
1
Negative Applied
No Voltage
0V
2
Negative Removed
0V
No Voltage
3
Positive Applied
No Voltage
12V
4
Positive Removed
12V
No Voltage
5 Negative
Logic
12V
0V
6 Positive
Logic
0V
12V
7.2.1 Output 1 State 1 Negative Applied:
¾
Dial
#
for Negative applied for Output 1
¾
A ‘
BEEP’
will be heard
¾
Dial
#
¾
“
SAVED, PLEASE ENTER COMMAND
” will be
heard
¾
Dial
¾
a ‘
BEEP’
will be heard
¾
Dial
¾
“
SAVED, PLEASE ENTER COMMAND
” will be
heard. You will be returned to the engineer menu.
7.2.2 Output 1 State 2 Negative Removed:
¾
Dial
#
for Negative removed for Output 1
¾
A ‘
BEEP’
will be heard
¾
Dial
¾
“
SAVED, PLEASE ENTER COMMAND
” will be
heard
¾
Dial
¾
a ‘
BEEP’
will be heard
¾
Dial
#
¾
“
SAVED, PLEASE ENTER COMMAND
” will be
heard. You will be returned to the engineer menu.