VOCALISER INSTALLATION MANUAL
Page: 14 RINS119-5
C H A P T E R 7 : O U T P U T S ( F L T & A C K )
The polarity of the outputs on the Vocaliser (see page 2, Vocaliser PCB) can be changed to
various different triggers.
7 . 1 T h e O u tp u ts ( F L T a n d A C K )
The two outputs on the Vocaliser can be selected to be pre-defined outputs (FLT) and
acknowledge (ACK) or general purpose outputs.
7.1.1 Output 1 (FLT)
If the output is programmed as ‘Fault’, then the output will activate when a line fault occurs.
If the output is programmed as ‘general purpose’ the user has control to toggle the output on or
off in the user menu (functions 55 - 58).
¾
Dial
to program Output 1 (FLT).
¾
A “
BEEP
” will be heard
¾
Enter either of the following:
o
Dial
to set the output for ‘Fault’. “
SAVED
”
will be heard.
or
o
Dial
to set the output as a general purpose
output . “
SAVED
” will be heard.
¾
“PLEASE ENTER COMMAND”
will then be heard
returning you to the engineer menu.
7.1.2 Output 2 (ACK)
If the output is programmed as ‘Acknowledge’, then the output will activate when all
acknowledgements from the phone calls have been received (please see user manual –
function 42). If the output is programmed as ‘general purpose’ the user has control to toggle the
output on or off in the user menu (functions 55 - 58).
¾
Dial
to program Output 2 (ACK).
¾
A “
BEEP
” will be heard
¾
Enter either of the following:
o
Dial
to set the output for
‘Acknowledgement’. “
SAVED
” will be heard.
or
o
Dial
to set the output as a general purpose
output (user has control to turn the output on
or off – see user manual functions 55 - 58).
“
SAVED
” will be heard.
¾
“PLEASE ENTER COMMAND”
will then be heard
returning you to the engineer menu.