11 / 38
EU20PIXV0501
Power Te/-
To connect battery power cables in series.
Power Switch
Switch the battery system’s (control module and high voltage DC power) ON/OFF.
Caution:
When the breaker is tripped off because of over current or short circuit, must wait
after 30min to turn on it again, otherwise may cause the breaker damage.
External Power Te/-
Connect battery system with Inverter.
Dry Contact Terminal
Dry Contact Terminal: provided 2 input and 4 output dry contact signal.
Reset
Reset Button: Long press this button to restart the battery system.
ADD
ADD Switch is a 6 bit dial switches to manually distribute the communication address of the
battery system. Nether position is OFF, means “0”. Upper position is ON, means “1”. For BMS, 1st
bit to 5th bit is for address allocation, and the 6th bit dial switch support a 120
Ω
resistance
(Terminal Resistance).
Start
Start function: press more than 5sec until the buzzer rings, to turn on controller.
Black start function: when system turned on and during self-check process, , press and hold the
start button again for more than 5sec, and relay will close for 10 min.
CAN / RS485
CAN Communication Terminal: (RJ45 port) follow CAN protocol, for communication between
battery system and Inverter.