45
6.
Storage Recommendations
For long-term storage, if stored for a long time (more than 3 months), the battery cells should be
stored in the temperature range for 5~45
℃
, relative humidity <65% and contains no corrosive gas
environment.
The battery should shelfed in 5~45
℃
, dry, clean and well ventilated environment. Before storage
the battery should be charged to 50~55% SoC;
It is recommended to discharge and charge the battery every 3 months, and the longest
discharge and charge interval shall not exceed 6 months.
Caution:
If not follow the above instructions to long term store the battery, will reduce
the life cycle of the battery.
7.
Shipment
For single battery cell will as 55%SOC or according to customer requirement before shipment. The
remaining capacity of battery cell, after shipment and before charge, is determined by the
storage time and condition.
1. The battery modules meet the UN38.3 certificate standard.
2. In particular, special rules for the carriage of goods on the road and the current dangerous
goods law, specifically ADR (European Convention on the International Carriage of Dangerous
Goods by Road), as amended, must be observed.