Photo 3
.
2
.
2
■
Photo 3
.
2
.
3
■
Photo 3
.
2
.
7
3.2.7 Mode Of Adding Count
Press ADD button,the machine is into
add counting mode, it adds up the last
counting number with the next counting
number.
(
photo 3.2.7
)
3.2.8 The Mode Of Checking
The Fake And Suspicious
The machine will stop and beep
when counting the broken or half bills.
the machine will stop and beep while
counting the fake bills/Suspicious bills.
(
Photo 3.2.8
)
3.2.9 Mode Of Batch Counting
Press BAT/C button, BAT indicator lights
on, then the machine is into batch counting
mode,Preset batch number by Press 0/1/2
/3/4/5/6/7/8/9, the machine will stop coun-
ting when the counting number is up to the
batch number
(
Photo 3.2.9
)
8
9
Operation Instruction
UV MG IR MT
PCS
PCS
COUNT
AUTO
DD
ADD
BAT
UV MG IR MT
PCS
PCS
COUNT
AUTO
DD
ADD
BAT
EE1
>FAKE NOTE
Remove note and press
COUNT
AUTO
ADD
BAT
>SUSPICIOUS NOTE
[reset] to continue
Operation Instruction
The fake bill or suspicious bill is being
checked out by IR
Take out the first bill(fake bill or suspicious bill)
in the stacker,then press(reset)to continue
counting and detecting
EE4
EE5
EE6
The half bill is being checked out
The left(right) counting sensor is dirty or brocken
Two bills are counted as one/inaccurate counting
The fake bill or suspicious bill with different
located magnetic is being checked out by MG
EE8
The bill wide length size is not within the range of
110-180mm
Take the half bill in stacker,then press(reset)
to continue counting and detecting
To clean it or change a new one
To tight the adjustable screw clockwise
Take out the first bill(fake bill or suspicious
bill)in the stacker,then press(reset)to
continue counting and detecting
Take out the first bill(fake bill or suspicious
bill)in the stacker,then press(reset)to
continue counting and detecting
3.3 Error -Message Dispaly
To change a new one or clean it
To change a new one or clean it
To clean it or tight it
To change a new one or clean it
To change a new one or clean it
To lower the ambient light
To lower the UV light
To change a new one or tight the connector
Solutions
Code No.
Malfunction causes
The left counting sensor is broken or dirty
The right counting sensor is broken
or dirty
The code disc is dirty or loosen
The hopper sensor is broken or dirty
The stacker sensor is broken or dirty
Ambient light is too high
UV sensitivity light is too high
The plastic button is broken or loose
E01
E02
E03
E04
E05
E10
E11
EE1
EE2
EE3
Code No.
Alarms meaning
Solutions
The fake bill reflecting fluorescence is being
checked out by UV
The fake bill without magnet is being checked
out by MG
At first , to take out the first bill (fake bill) in
the stacker then to press [reset] to continue
counting and detecting
At first , to take out the first bill (fake bill)
in the stacker then to press [reset] to
continue counting and detecting