RDM – available parameters

The PX803-W supports the DMX-RDM protocol. DMX protocol allows only 

of a one-way data transmission, while extension the RDM protocol can 
transmit information in two directions. This makes possibility of monitoring 
activities of the compatible devices. Thanks to RDM some available settings 
of compatible devices may be programmed using this protocol.
List of RDM parameters supported by the PX803

 

 -W

   :  

Parameter name

PiD

Description

SUPPORTED_PARAMETERS

0x0050 all supported parameters

PARAMETER_DESCRIPTION 0x0051 description of additional 

parameters

DEVICE_INFO

0x0060 information concerning the device

SOFTWARE_VERSION_LABEL 0x00C0 firmware version of the device
DMX_ADDRESS *

0x00F0 DMX starting address of the device

IDENTIFY_DEVICE *

0x1000

device identification;

Two states are possible: 

identification is off (0x00 value)

and identification is on (0x01 value)

DEVICE_MODEL_

DESCRIPTION

0x0080 device description, e.g. name

MANUFACTURER_LABEL

0x0081 manufacturer description,

e.g. name

DEVICE_LABEL *

0x0082

additional device description;

It is possible to enter an additional 

device description using up to 32 

ASCII characters

13

Содержание PX803-W

Страница 1: ...PX803 W PxArt XL Mono Wall User manual...

Страница 2: ...arameters 10 6 2 The PX803 W menu diagram in PX277 12 7 RDM available parameters 13 8 DMX signal connecting 15 9 Mounting 15 10 Connection scheme 16 11 Dimensions 17 12 Technical data 18 Manufacturer...

Страница 3: ...e a lamp that is devoid of the effect of light vibration flicker free technology in the full control range which makes it useful in the television industry The device has a handle that allows it to be...

Страница 4: ...s Warning Read the instruction manual Caution Do not look at the LEDs LEDs can cause damage or eye irritation Do not look at the light source with any optical devices that focus the light rays Light i...

Страница 5: ...d must meet the safety requirements the installation must be 3 wire and equipped with a residual current device 3 All the conductors should be protected against mechanical and thermal damage 4 In the...

Страница 6: ...lamp is available in several versions that differ for example in the angle of the lenses used Below is a description of the PX803 W markings and their explanation PX803 W BB XX YYY Z BB version XL la...

Страница 7: ...tor angle 15 15 36 36 51 51 YYY CRI and color temperature X30 CRI 95 temp 3000K 930 CRI 90 temp 3000K 950 CRI 90 temp 5000K 830 CRI 80 temp 3000K 850 CRI 80 temp 5000K Z housing color 1 gray 2 black 3...

Страница 8: ...of the lamp in case of the loss of DMX signal diode lights continuously for 1 minute if the state of DMX signal changed if there wan no DMX signal and it returned or vice versa diode signals it for 1...

Страница 9: ...p brightness Setting the lamp parameters Value of the lamp parameter Value of the DMX signal Brightness adjustment 100 255 50 128 0 0 6 Cooperating with the PX277 configurator The PxArt Mono Wall sett...

Страница 10: ...ce reaction time after the disappearance of the DMX signal 0 0 10s Smooth smooth changes in DMX signal value OFF Level 1 4 Control mode operating mode selection 1ch MONO 1 DMX channel for brightness c...

Страница 11: ...Control Mode 1ch MONO Firmware version software version Serial Number serial number 11...

Страница 12: ...128 ENTER PREV No Signal Time 0 0 s No Signal Time 1 0 s NEXT No Signal Time 10 0 s ENTER No Signal Time 1 0 s NEXT Smooth Off NEXT NEXT Control Mode 1ch MONO NEXT Smooth Off Smooth Level 1 NEXT Smoot...

Страница 13: ...RS 0x0050 all supported parameters PARAMETER_DESCRIPTION 0x0051 description of additional parameters DEVICE_INFO 0x0060 information concerning the device SOFTWARE_VERSION_LABEL 0x00C0 firmware version...

Страница 14: ...information on the selected temperature sensor SENSOR_VALUE 0x0201 information about sensors SMOOTH_OFF 1 2 3 4 0x801A selection of smoothing options NO_SIGNAL_OFF ON HLD S 0x801C behavior of the dev...

Страница 15: ...below If the PX803 W is the last device in the DMX line then a terminator 120 Ohm resistor should be connected to the DMX and DMX terminals DMX IN GND CORRECT DMX 512 input DMX 512 output DMX IN GND...

Страница 16: ...10 Connection scheme L N PE GND DMX DMX L N PE GND DMX DMX L N PE GND DMX DMX 230V AC DMX controller DMX PX803 W PX803 W PX803 W Max 32 devices on the line Terminator 120 Ohm resistor 16...

Страница 17: ...11 Dimensions 17 183 307 120 87...

Страница 18: ...94 max increase of the housing temperature 50 C color rendering index CRI min 80 lifetime of diodes 50000h reflector angles 15 36 51 brightness adjustment range 0 100 control DMX RDM mounting to the w...

Страница 19: ...ing directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Te...