E_P
– exponential
◦
nE1
…
nE3
– for neon lamps control *
◦
Li2
– linear 15 – 100% (zero value at the power output for DMX
values 0 – 15%)
3.
ACL
– limits the output voltage in the range from 50 – 230V
6.2.3 Temperature
°C
– this parameter allows to check the dimmer internal temperature in
the range -40 to +125°C.
NOTE! Message
Er1
means sensor failure, so service is necessary.
Dimmer has been equipped with thermal protection with the following
settings for the temperatures inside the dimmer:
•
60°C – automatic start of the electronically controlled fan
•
90°C – 10% drop in power output and 10% more with each subsequent
1°C
•
100°C – automatic switch-off of the dimmer
After cooling and lowering the temperature to 70°C, the device starts
working again at full power.
6.2.4 Input mode
AdC
– switching between default digital control mode (DMX-512, setting
OFF
) and analog mode (0 – 10V control signal or external button – setting
On
).
16