Inu
– inverted
◦
LnU
– logarithmic
◦
E_P
– exponential
◦
nE1
…
nE3
– for neon lamps control *
◦
Li2
– linear 15 – 100% (zero value at the power output for DMX
values of 0 – 15%)
3.
ACL
– limits the output voltage in the range from 50 – 230V
4.
PrE
– heating up the bulbs filaments, set in range from 0 – 10%
5.
FSo
– dimmer wake up after power supply connection
6.2.2 Individual parameters
1.
AIn
– analog control input settings for each channel:
◦
AnL
– voltage control 0 – 10V (for 0V total dimming, for 10V
maximum brightness) using a 10kΩ linear potentiometer or an
external control voltage
◦
bIn
– settings for monostable external button:
▪
Fun
– 5 functions to choose from (see charts in item 6.3)
▪
rIS
– brightness rising time to maximum allowed by output
ACL
voltage – from 0 (immediately) to 255 seconds
▪
LAS
– duration time from 0 to 9990 seconds
2.
Cur
– characteristic, there are 9 options to choose from:
◦
Lin
– linear
◦
SP
– switchable
◦
Inu
– inverted
◦
LnU
– logarithmic
15